Every term in the City & Guilds 8202-35 Advanced Technical Diploma, explained in plain English — 1720 words and abbreviations across all 6 units. The vocabulary comes from the standard rather than from general trade usage, because the words on the exam paper are the standard’s words. Where the trade has a second name for something, the definition says so.

…

Abrasion

Unit 333Damaged cable: recognising it and putting it right

Wearing away of a cable sheath by rubbing against a hard edge, typically at an unbushed metal knockout or where a cable crosses a sharp corner.

Abrasive wheel

Unit 336Equipment and energy: wheels, isolation and refrigerant

A bonded wheel used for cutting or grinding at high speed. It must be ring tested before use, fitted with manufacturer-recommended parts, and run with the guard close to the wheel.

Absolute zero

Unit 335Heat pumps: how the refrigeration cycle moves heat

0 K, or −273 °C, the temperature at which no heat energy remains. Everything warmer than this contains heat that a heat pump can in principle collect.

Absorbent

Unit 336Substances on site: data sheets, glycol and spills

A material such as granules or pads kept in a spill kit, used to soak up a spilled liquid so that it can be collected and disposed of properly.

Absorber

Unit 335Collector performance: aperture area and the efficiency curve

The coated surface inside a solar collector that receives solar radiation and passes the heat to the fluid circulating through it.

Absorber plate

Unit 335Collectors: flat plate, evacuated tube and unglazed

The element of a collector that receives and absorbs the solar radiation and converts it into heat, then passes it to the fluid in the tubes bonded to it.

Abstraction licence

Unit 335Ground source heat pumps: the four collector types

A consent from the environmental regulator to take water from the ground or a watercourse. Open loop systems normally require one.

Acceptance factor

Unit 332Sizing pumps and expansion vessels

The fraction of an expansion vessel’s volume that is actually available to take expansion, the rest being taken up by the gas charge behind the diaphragm. It is 1 minus the charge pressure divided by the maximum pressure, both worked in absolute pressure.

Acceptance volume

Unit 333The expansion vessel: position, charge pressure and size

The volume of expansion water a vessel will actually take. The practical figure is measured at 0.35 bar below the safety valve setting.

Access arrangements

Unit 336Method statements: what they are and contain

The planned means of getting to and from the place of work safely, such as the procedure for reaching a roof or entering an excavation, recorded in the method statement.

Access hatch

Unit 331Linked and sectional cisterns in the plant room

A small opening in a bolted cistern lid that lets the cistern be inspected, cleaned and its inlet valve adjusted without removing the whole cover.

Access panel

Unit 334Air admittance valves: the conditions they need to work

A removable section of boxing or casing that lets a component behind it be reached for inspection, maintenance or replacement.

Access point

Unit 334Blockages: where they form and how they are cleared

An opening in pipework, such as a cover, cap or clearing eye, provided so the pipe can be cleared and tested. It is positioned so its use will not cause a nuisance.

Accident book

Unit 336Reviewing and reassessing: keeping it true

The record in which work-related injuries and incidents are entered, giving the details needed for investigation and for any report to the enforcing authority.

Accident investigation

Unit 336Reviewing and reassessing: keeping it true

The examination of what actually happened after an accident or near miss, to find which control was missing, defeated or inadequate so that it can be put right.

accredited RPZ tester

Unit 331RPZ valves and single and double check valves

A person who has passed an approved training course and is registered to commission and test RPZ valves. A new RPZ must be commissioned by one, and then tested every year, with the results sent to the water undertaker.

Accumulator

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A vessel with water held against compressed air that keeps the system pressure up while the pumps are idle. On booster set diagrams it is also labelled the expansion vessel.

ACOP L8

Unit 331The commissioning record and the defects that go on it

The HSE Approved Code of Practice on Legionella, which requires records of monitoring, inspection, tests and checks to be kept for at least five years.

Action plan

Unit 336Writing it down: forms, formats and who signs

The part of a risk assessment form listing further action required, who will carry it out, by when, and the date it was completed.

Activated carbon filter

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A cartridge that absorbs chlorine, pesticides, taste and colour. It can breed bacteria, so it is not used on water of unknown quality.

Active heated area

Unit 333Joisted floors: emission plates, foil and output figures

The area actually covered by the heating element, used when quoting output. For a plated floor it is the aluminium area alone, with joists and return bends deducted.

Active system

Unit 335Solar thermal: what it delivers and how the circuit works

A solar thermal system in which a pump circulates the heat transfer fluid between collector and store.

Activity space

Unit 334Sanitary appliances: how many, how much space, which type

The clear floor area in front of or beside an appliance that a person needs in order to use it, given in BS 6465-2. Activity spaces may overlap one another.

Actuator

Unit 333First fix: the manifold, the sequence and other trades

The small electrothermal head on the return manifold that closes a circuit when its room thermostat is satisfied.

Addition or alteration

Unit 333Checking the existing circuit: rating, condition and damage

Work that adds to or changes an existing installation, such as taking a new spur off a circuit. It triggers the checks of Regulation 132.16 and requires certification.

Additional protection

Unit 333Supplying and isolating the controls on site

Extra protection against electric shock provided by a residual current device with the characteristics required by BS 7671, used where basic and fault protection alone are not enough.

Adjacent floors

Unit 334The stack performance test: choosing appliances from Table NG.1

Floors immediately next to one another. Stack test appliances are placed close to the top of the stack and on adjacent floors to give the worst pressure conditions.

Administrative control

Unit 336Control measures and the hierarchy of control

A control that works through the organisation of the work, such as a safe system of work, a permit, training, sequencing, signs or supervision.

Aeration

Unit 333Pumping over and persistent venting on open vented systems

Air being drawn into or churned into system water, bringing oxygen that accelerates corrosion.

Aerator

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A tap outlet that mixes air into the stream so it feels fuller while using less water.

Air admittance valve (AAV)

Unit 334Air admittance valves, stack terminations and housing sites

A one-way valve to BS EN 12380 fitted at the top of sanitary pipework. It admits air to relieve negative pressure but does not let foul air escape, allowing a stack to terminate inside a building.

Air change rate

Unit 333Heat loss: the fabric route and the ventilation route

How many times the air in a defined space is replaced each hour, found by dividing the volume of air passing through the room in an hour by the volume of the room.

Air charge differential

Unit 331Borehole pumps: packaged sets, controls and the accumulator

On an accumulator charged from a main, the amount by which the air charge is set below the mains pressure so water can enter: about 1.5 bar, never less than 0.8 or more than 2 bar.

Air compressor

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The compressor on a self-assembled set that keeps a pneumatic pressure vessel charged with filtered air.

air gap

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

A gap of open air between the lowest point of a water outlet and the spill-over level of the vessel or appliance it discharges into, so that no pipe joins the wholesome water to the contents. It is a non-mechanical backflow arrangement with nothing to wear or jam, and the only protection accepted for fluid category 5.

air inlet valve

Unit 331Draining down, standing water and diagnostic readings

A valve at a high point that opens to let air into pipework as it drains. Without air entering, check valves at the outlets can hold a vacuum and a cylinder can collapse.

air lock

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

A pocket of air trapped at a high point in pipework or inside a pump that stops or reduces the flow of water. A pump is cleared by priming; pipework is avoided one by filling slowly with the highest outlet open.

Air separator

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

A fitting that combines the vent, feed and system connections at the neutral point and removes entrained air from the circulating water.

Air source heat pump (ASHP)

Unit 335Air source heat pumps: frost, defrost and fault finding

A heat pump that extracts low-grade heat from outside air, drawn across an evaporator coil by a fan, and delivers it to a heating system.

air test

Unit 331Identifying non-wholesome pipework and testing for cross connections

A soundness test in which a section of pipework is sealed, pressurised with air and watched on a gauge for any drop in pressure. BS 8525-1 requires one on the wastewater connections and on the greywater distribution pipework before handover.

Air tightness

Unit 334The air test requirement: 38 mm water gauge for 3 minutes

The ability of pipes, fittings and joints to hold a positive air pressure without leaking, so that foul air cannot escape into the building.

Air vent

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

A vent or open tap at a high point through which air escapes as the system fills, closed once water shows at it.

Air-to-air heat pump

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

A heat pump that takes heat from outside air and delivers it into the dwelling as warm air, usually through indoor fan units. It produces no domestic hot water.

Airlock

Unit 332Scale, blockages, airlocks and leaks

Air trapped at a high point in pipework that stops or interrupts the flow of water. It is cleared by draining and refilling, or vented at the high point.

Albedo

Unit 335The solar resource: irradiance, insolation and the seasons

The proportion of incoming solar radiation reflected back to space by cloud, the atmosphere and the earth's surfaces.

Allocation by area

Unit 336Quality checks: allocating areas, inspecting and testing

Giving each operative responsibility for a defined part of the building, so that ownership of quality and the route for tracing a defect are both clear.

Ambulant accessible cubicle

Unit 334Activity space: sanitary accommodation people can use

A WC cubicle sized and fitted with grab rails for a person who can walk but has limited mobility. Detailed in BS 8300.

Angle of inclination

Unit 335Orientation, tilt, shading and permitted development

The angle of a collector from the horizontal. In the UK the optimum is 30 to 40 degrees, with 35 degrees as a working default.

animal drinking trough

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

A trough from which livestock drink, fluid category 5 because of animal saliva and waste. It is filled through a type AA air gap: a rigidly fixed float valve in a locked, covered housing on the trough edge, with the water level at least 25 mm below spill-over.

anode

Unit 331Galvanic corrosion and the seven steps to handover

In a galvanic cell, the less noble metal, which gives up electrons and is corroded away — zinc against copper, for example.

Anti-legionella valve

Unit 332Composite valves, vacuum relief and anti-legionella valves

A valve on the expansion vessel connection that makes the vessel's contents exchange with the flow each time water is drawn, so the water in it cannot stagnate.

Anti-vacuum trap

Unit 334When a branch is too long: ventilating pipes and air admittance valves

A trap fitted with a valve that admits air when negative pressure occurs, so the seal is not siphoned away. A resealing trap does a similar job by retaining part of its water.

Anti-vibration coupler

Unit 332Pump faults: secondary circulation and shower boosters

A short flexible connection fitted at a pump's inlet and outlet to stop vibration passing into the pipework. If it is bent or distorted it restricts the flow.

Anti-vibration mount

Unit 335Siting outdoor plant: air source units and ground loops

A resilient mounting between a unit and its base or bracket that stops vibration passing into the structure.

Aperture area

Unit 332Solar and twin-coil cylinders: which coil takes which source

The area of a solar collector that actually admits sunlight, used as the basis for sizing the solar coil and the dedicated storage volume.

Appeal

Unit 336Dealing with poor work: informal action and the formal procedure

The stage of the formal procedure at which an employee can challenge the decision made about them.

Appliance space

Unit 334Sanitary appliances: how many, how much space, which type

The plan area taken up by the appliance itself, including closely related pipework and fittings.

Application for payment

Unit 336Cost monitoring: storage, wastage and the monthly payment

The contractor's monthly submission setting out the value of work done and materials on site, on which the interim payment is based.

Apprentice

Unit 336Craft levels and allocating work: who supervises whom

A trainee learning the trade under supervision. They hold very little responsibility for installations and require full supervision at all times.

appropriate quality and standard

Unit 331Regulations 3 and 4: installer tests and user duties

The first of the two Regulation 4 tests every water fitting must pass: it must be made to an appropriate British Standard or equivalent, or to a specification approved by the regulator. Conformity is usually shown by an approval mark or listing, but that is evidence, not the legal test itself.

Approved Code of Practice (ACOP)

Unit 336The regulations that sit under the Act

Practical guidance approved by the HSE on how to comply with the law. Following it is enough to comply; departing from it means proving compliance another way if prosecuted.

approved contractor

Unit 331Approved contractors: certificates of compliance and other notices

A person approved by the water undertaker for the area, or certified by an organisation the regulator has specified in writing, to install water fittings. An approved contractor need not notify items 2, 4(b) and 4(g) (alterations on premises other than a house, ascending-spray bidets and RPZ valves) but must give a certificate of compliance to the customer, and that certificate gives the customer a statutory defence.

Approved Document

Unit 332Statutory rules, standards and guidance: which document does what

Official guidance published to show how the requirements of a part of the Building Regulations can be met. Following it is the normal route to compliance.

Approved Document G

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The government guidance on meeting Part G of the Building Regulations 2010 (sanitation, hot water safety and water efficiency). Its section on cold water says supply from an undertaker through an installation complying with the Water Fittings Regulations may be assumed wholesome, and it lists the competent person schemes that can self-certify.

Approved Document L

Unit 332Efficiency, carbon and cost: what the heat source decides

The Building Regulations guidance on conservation of fuel and power. It sets efficiency, insulation, controls and commissioning provisions for dwellings, and is supported by a compliance guide.

Approved Document P

Unit 333Boiler interlock, CHeSS and signing the work off

The Building Regulations approved document covering electrical safety in dwellings, under which electrical work on heating controls is certificated.

Approved inspector

Unit 334Notifying building control: notices, full plans and competent persons

A private body approved to carry out the building control function in place of the local authority, working under an initial notice.

Approved voltage indicating device

Unit 334Safe isolation before working on powered sanitary components

A test instrument made to GS38 for proving a circuit dead. It is proved on a known supply or proving unit before and after the test.

Approved voltage indicator

Unit 336Equipment and energy: wheels, isolation and refrigerant

A test instrument suitable for proving a circuit dead. Volt sticks and neon screwdrivers are not suitable for the purpose.

Aquifer

Unit 331Private water supplies: sources and responsibilities

A layer of rock or gravel that holds ground water like a sponge, from which wells and boreholes draw.

Architect

Unit 336The design team: architect, engineers and surveyor

The designer who turns the client's requirements into a building design and working drawings, oversees the work until handover and administers the contract.

Article 4 direction

Unit 335Permitted development: what it means, and solar on a roof

A direction by which a local authority withdraws permitted development rights in a defined area, so an application is needed for work that would otherwise be allowed.

As-built information

Unit 336Accepting finished work: snagging, records and handover

Drawings and records showing what was actually installed, as distinct from what was designed, provided at handover as the contract requires.

As-fitted drawing

Unit 331Visual inspection: the documents and the dry checklist

A drawing or schematic of an existing installation showing the pipework as it was actually installed, consulted so that only the intended parts of a system are worked on.

Asbestos

Unit 336Hazard and risk: telling the two apart

A fibrous mineral used in older buildings for insulation and boarding. Its dangerous form is airborne dust, which causes fatal lung disease when inhaled.

ascending spray bidet

Unit 331Regulation 5 notification: the list and the ten working days

A bidet whose spray comes up from below the rim, or that has a flexible hose, so that the outlet can be submerged in used water. It is a fluid category 5 risk, must be fed from a dedicated cistern or through a suitable backflow arrangement, and is notifiable under item 4(b) of Regulation 5.

Attendance times

Unit 336Presenting a method statement: headings and format

The dates and hours during which the team will be on site, recorded in the method statement so that the client and other trades can plan around them.

Attenuation

Unit 334Combined, separate and partially separate drainage

Holding surface water back in storage, such as a detention pond, so the peak rate of flow passed on to a sewer or watercourse is reduced.

Automatic air inlet valve

Unit 331Multi-storey supply: the mains limit and the break cistern

A valve on the upstand of a drinking water header that lets air in and out as the water level in the header rises and falls.

Automatic air release valve

Unit 333Poor circulation: air locks, blockages and pump faults

A valve fitted at a high point that vents trapped air from the system automatically as it collects.

Automatic air vent

Unit 333Wiring centres, programmers, pump overrun and frost protection

A float-operated vent fitted at a high point that releases air from the system automatically as it collects.

Automatic bypass valve

Unit 333Zone valves: two-port, mid-position and diverter

A spring-loaded differential pressure valve connecting flow to return, which opens on system pressure when the zone valves and TRVs close, maintaining a minimum flow through the boiler.

automatic garden watering system

Unit 331Filling loops and outside taps: protecting heating and garden connections

An irrigation system that runs without someone holding the hose, such as sprinklers, drip lines or porous hoses on a timer. It is a Regulation 5 notifiable fitting and, with buried or porous parts, fluid category 4 in a house garden and 5 elsewhere.

Automatic setback

Unit 333Underfloor with radiators: mixed temperature systems and zones

A control facility that lowers the room temperature setting at night or during unoccupied periods instead of switching a slow system off.

Automatically flushed urinal cistern

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A cistern that fills slowly and siphons to flush the urinals whenever it is full, limited by Schedule 2 paragraph 25 to 10 or 7.5 litres per hour per bowl.

Auxiliary heat source

Unit 332Thermal stores and solar thermal: their pipework layouts

The second heat source, usually a boiler or an immersion heater, that a solar system must have available so the water can be brought up to temperature when there is not enough sun.

Auxiliary switch

Unit 333Zone valves: two-port, mid-position and diverter

The switch inside a motorised valve head that makes when the valve reaches its open position, sending the switched live on to the boiler and pump.

available head

Unit 331Available pressure and flow, feed arrangements and loading units

The pressure that can be used to push water through the pipe to an outlet. For a cistern-fed system it is the vertical distance from the base of the cistern to the outlet; for a mains-fed system it is the minimum mains pressure at peak demand, less any rise to the outlet.

Axial tilt

Unit 335The solar resource: irradiance, insolation and the seasons

The 23.5 degree tilt of the Earth's axis relative to its orbital plane, which causes the seasons by changing day length and the angle of the beam.

Azimuth

Unit 335Orientation, tilt, shading and permitted development

The compass direction a collector faces, measured from due south. Due south is 0 degrees, south-west plus 45 degrees, due west plus 90 degrees.

back pressure

Unit 331Backflow risk: the duty and the five fluid categories

Backflow caused by the pressure on the consumer's side rising above the supply pressure, so water is pushed back towards the main. A pump, expansion in a hot water system or a burst main with the consumer's pipework still full can all cause it.

back siphonage

Unit 331Backflow risk: the duty and the five fluid categories

Backflow caused by a negative pressure in the supply pipe sucking water back through a submerged outlet, like drinking through a straw. A burst main while a hose lies in a bath, pond or pool is the classic case.

Back-up water supply

Unit 335Greywater re-use: a steadier supply, a heavier burden

The wholesome water supply that makes up the shortfall when a rainwater or greywater store runs low. It must be protected by an air gap and fitted with a warning mechanism.

Backfeed

Unit 333Electrical faults on the controls: supply, fuses and wiring

A voltage reaching a terminal by another route through the circuit, which produces false readings unless the terminal is disconnected during testing.

Backfilling

Unit 331Soundness testing: current standards, equipment and procedure

Refilling a trench over underground pipework. The pipe is inspected and tested before it is backfilled.

backflow

Unit 331Fluid categories: grading water and regrading a building

Water flowing in the wrong direction, from a fitting or appliance back towards the supply, either because the supply pressure drops (back-siphonage) or because the downstream pressure is higher (back pressure). It is the main route by which contamination reaches the mains, so Schedule 2 paragraph 15 requires a backflow prevention device matched to the fluid category.

backflow device

Unit 331Fluid categories: grading water and regrading a building

A fitting or arrangement that stops water flowing back towards the supply: an air gap, a check valve, a double check valve, an RPZ valve or a pipe interrupter, chosen to match the fluid category of the risk. Mechanical ones must be made of gunmetal or dezincification-resistant material and must be accessible for testing and renewal.

Backflow loop

Unit 334Waste water lifters and sink waste disposal units

A rise in the discharge pipe from a lifting plant that goes above the level of the sewer before dropping into the drain, so the sewer cannot flow back into the unit.

backflow prevention device

Unit 331Backflow devices: testing check valves and maintaining the RPZ valve

A fitting that stops water flowing backwards from a system into the supply — an air gap, check valve, pipe interrupter or RPZ valve — chosen to suit the fluid category of the risk. They contain springs, seats and diaphragms that wear, so BS EN 806-5 Annex B sets out how each type is tested and maintained.

Background heating

Unit 333Where a heating design starts: the customer's brief

Heating that holds the whole property at a reduced temperature rather than at full comfort. It takes the chill off and protects against frost and condensation.

Backwash

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Cleaning a sand or pressure filter by reversing the flow through the bed to flush out the trapped sediment.

Bacteriological sample

Unit 331Chlorine disinfection: the figures, the people and the samples

A water sample taken two to seven days after disinfection and analysed for micro-organisms to prove the treatment worked.

Balanced cold connection

Unit 332Expansion on an unvented system: vessel, valve and balanced cold

The cold water take-off to the outlets, made after the pressure reducing valve and before the single check valve, so hot and cold reach mixers at comparable pressures.

Balanced cold supply

Unit 332Looking before testing: classic installation defects

A cold water supply taken from the cold feed to an unvented cylinder, downstream of the pressure reducing valve, so that hot and cold arrive at a mixer at the same pressure.

Balanced cold take-off

Unit 332Commissioning temperatures: stored, at the tap and at the bath

A cold connection taken downstream of the pressure reducing valve on an unvented system, so hot and cold reach a mixer at the same pressure and the blend stays stable.

Balanced supplies

Unit 331Balancing, mechanical controls and functional testing

Hot and cold supplies arriving at a mixing valve at similar pressures, needed by some mixers and not by others.

Balancing

Unit 331Balancing, mechanical controls and functional testing

Adjusting regulating or pressure reducing valves so that every outlet gets its design flow and pressure rather than the nearest taking everything.

Balancing report

Unit 333The commissioning record: what to write down and why

The record of the balancing exercise: the valve settings applied and the flow rates or temperature differences achieved on each circuit. BS EN 14336 includes it in the handover documentation.

ball valve

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

In this lesson, a quarter-turn valve with a drilled ball that turns to open or close the way — not a float valve. It is a good servicing valve because the lever shows at a glance whether it is open and it is not easily knocked.

Bar

Unit 331Soundness testing: test pressures for metal and plastics pipework

The unit of pressure used for testing; 1.5 times a 3 bar working pressure is 4.5 bar.

Bar absolute

Unit 333Expansion: sizing the vessel and the feed and expansion cistern

Pressure measured from a complete vacuum rather than from atmospheric pressure. It equals the gauge reading plus 1 bar, and both pressures in the vessel formula are absolute.

Barrier pipe

Unit 333Laying the underfloor pipe: centres, fixing and joints

Plastic heating pipe made with an oxygen barrier layer in the wall. It stops oxygen diffusing into the system water and corroding ferrous components.

Base-exchange softener

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A water softener that swaps the calcium and magnesium that make water hard for sodium. Checked with pH strips and a hardness test.

Baseline

Unit 333Filling and venting underfloor circuits and ground collectors

A measured value recorded at commissioning so that a later reading can be compared with it. Without a baseline, a later measurement cannot show whether anything has changed.

Basic protection

Unit 333Visual inspection of the completed controls

Protection against electric shock under fault-free conditions, provided by insulation of live parts and by barriers or enclosures.

bath and shower combination mixer

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

A bath filler with a diverter and a flexible shower hose, fed by hot and cold supplies. Because the hose can drop into the bath water it needs category 3 protection: double check valves on both feeds, a retaining ring, or a built-in type HC diverter.

Bath/shower mixer

Unit 331Check valves, water hammer and the mini expansion vessel

A bath tap with a diverter and flexible shower hose, designed for equal hot and cold pressures.

Bathroom greywater

Unit 335Rainwater and greywater: what the building must offer

Greywater from baths, wash and hand basins, showers and clothes washing machines. It is the source covered by BS 8525-1.

Batten

Unit 336Sequencing with other trades and site readiness

A timber fixed into a wall or studwork to give a solid fixing point for an appliance, radiator or bracket.

BBOE (bottom bottom opposite end)

Unit 333Radiators: fixing height, brackets and valve connections

The usual radiator connection arrangement, with flow and return entering the bottom of the radiator at opposite ends.

Bearers

Unit 332Looking before testing: classic installation defects

The timbers or supports on which a cold water storage cistern sits. They must be sound and able to carry the cistern filled to the rim, spreading the load across the whole base.

Benchmark

Unit 332Units, packages, approval and commissioning records

The industry commissioning checklist and logbook for heating and hot water appliances, recording installer details and the safety-critical checks made at commissioning.

Benchmark checklist

Unit 333Boiler interlock, CHeSS and signing the work off

The commissioning checklist and service log supplied in the boiler literature, completed at handover and left with the customer.

Benchmark Commissioning Checklist

Unit 332Commissioning records and dealing with defects

The industry checklist supplied in the back of most appliance manuals, completed by the person commissioning the system to show that the checks were made and the results were satisfactory.

bi-flow fitting

Unit 331RPZ valves and single and double check valves

A mixer tap or shower fitting whose hot and cold waterways stay separate all the way to the outlet, so the two waters only meet in the air. Because hot cannot cross into cold inside it, BS 8558 does not require check valves on its feeds.

bib tap

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

A tap with a horizontal inlet, fixed to a wall or pipe rather than to the appliance; hose union taps and the taps over a cleaner's sink are bib taps. Over a sink it must be set high enough for the AUK3 gap.

bill of quantities

Unit 331Design information: manufacturer data, customer feedback and scale plans

A document prepared by the quantity surveyor from the architect's drawings that lists every item of labour and material for a job, so contractors can price it line by line. With the floor plan it is the pair used to cost a job before it starts.

Bio-mechanical system

Unit 335Greywater re-use: sources, treatment and storage limits

The most advanced domestic greywater system, combining filtration, bio-culture treatment with settlement and a UV filter before storage.

Biocide

Unit 333Cleansers, neutralisers, inhibitors and the in-line filter

An additive that inhibits microbiological growth. BS 7593 asks for it to be considered on systems designed to run below 60 °C.

Biomass

Unit 335Micro-renewable technologies: what each one produces

Biological material burned to produce heat. The main domestic fuel is wood pellets, with logs and wood chips as alternatives.

Bivalence point

Unit 335Monovalent, bivalent systems, buffers and system volume

The outdoor temperature at which the second heat generator in a bivalent system has to start contributing.

Bivalent system

Unit 335Monovalent, bivalent systems, buffers and system volume

A system using two or more heat generators of different kinds, such as a heat pump with a boiler or an electric heater.

Blackwater

Unit 335Greywater re-use: sources, treatment and storage limits

Wastewater containing faecal matter and urine, such as WC discharge. It goes to the foul drain and cannot be re-used within a building.

Bladder

Unit 331Borehole pumps: packaged sets, controls and the accumulator

The synthetic rubber (neoprene) bag inside an accumulator that holds the water, with compressed air around it.

Bladder type expansion vessel

Unit 332Expansion on an unvented system: vessel, valve and balanced cold

An expansion vessel in which the water is contained inside a neoprene bag, so it never touches the steel shell. This is the type used on unvented hot water systems.

Blended volume

Unit 332Working out the daily hot water demand for a dwelling

The volume of usable warm water a store yields once it is mixed with cold at the outlet. Stored water at 60 degrees goes further than its own volume when blended down to 40.

Blending valve

Unit 333The underfloor manifold: blending, balancing and safety

A thermostatic mixing valve on an underfloor manifold that mixes hot primary flow with cooled return water to give the low temperature the floor circuits need.

block plan

Unit 331Design information: manufacturer data, customer feedback and scale plans

A small-scale plan showing where the site sits among the neighbouring buildings and roads. It is drawn at a smaller scale than a site plan and is too small to locate a stop valve or a pipe.

blue water corrosion

Unit 331Draining down, standing water and diagnostic readings

A copper-pipe problem in which very fine copper corrosion products turn the first draw of water blue-green and stain sanitaryware. It is caused by water standing in copper pipe — especially new pipe that has not yet formed its protective film, or pipe with flux left inside — and is cured by thorough flushing.

Boiler interlock

Unit 333Boiler interlock, CHeSS and signing the work off

A wiring arrangement interconnecting the system controls so that the boiler and pump are switched off when there is no demand for space heating or hot water. It is not a physical device.

Boiler management system (BMS)

Unit 333Weather compensation, optimum start and home automation

An electronic controller that monitors temperatures and system operation and adjusts times and setpoints automatically, learning how the building heats and cools.

boosted set

Unit 331RPZ valves and single and double check valves

A set of pumps drawing from a break cistern to raise the pressure in a building's cold water system. Each pump outlet carries a single check valve so water cannot drain back through an idle pump to the cistern.

Boosted system

Unit 331Direct, indirect and boosted systems: extra checks and first fill

A system in which pumps raise the pressure, either from a break cistern (indirect boosting) or from the supply pipe with the undertaker's consent (direct boosting).

Booster pump

Unit 332Shower pumps, accumulators and shock arrestors

A pump fitted to raise the pressure of an incoming supply. Taken directly from the main it may not deliver more than 12 litres per minute.

Booster set

Unit 331Multi-storey supply: the mains limit and the break cistern

The assembly of pumps, controls and vessel that raises cold water to the floors the main cannot serve.

bore

Unit 331Draining down, standing water and diagnostic readings

The inside diameter of a pipe. A rough or scaled bore, a small bore and every extra tee or elbow all cost pressure between the main and the outlet.

Borehole

Unit 331Private water supplies: sources and responsibilities

A drilled hole 100 to 150 mm across, reaching up to about 50 m into an aquifer, from which water is lifted by a submersible pump.

Borehole heat exchanger

Unit 335Siting outdoor plant: air source units and ground loops

A vertical ground collector installed in a drilled and grouted borehole, used where the land available for trenches is limited.

Boss connection

Unit 334Joining branches to the stack: cross-flow and the no connection zone

A moulded or strap fitting on a stack or branch that takes a small waste pipe, such as a 32 mm or 40 mm branch, into a larger pipe.

Bottle trap

Unit 334Checking traps, branch pipes, gradients and falls

A trap with a dip tube or vane inside a cylindrical body, the lower part of which unscrews for access. BS EN 12056-2 ND.2.3 restricts it to wash basins.

boundary stop valve

Unit 331Design information: manufacturer data, customer feedback and scale plans

The water undertaker's stop valve at the boundary of each property, where the communication pipe from the main ends and the consumer's supply pipe begins. Its position on a new estate is found on the site plan.

Bourdon pressure gauge

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A dial pressure gauge worked by a curved tube that straightens under pressure, fitted on pump inlet and outlet to show the pump is delivering.

Bowser

Unit 331Direct, indirect and boosted systems: extra checks and first fill

A towed water tank used on site. Its water is not fluid category 1 and must not be used to fill a drinking water system.

Boyle's law

Unit 331Booster sets: the pressure vessel and the control switches

The gas law that the pressure of a fixed mass of gas rises as its volume falls, which decides how much water a vessel can deliver between cut-out and cut-in.

Branch discharge pipe

Unit 334Primary ventilated stacks: the branch limits that decide the layout

The pipe carrying the discharge from one or more appliances to a discharge stack, another branch or a drain.

Branch ventilating pipe

Unit 334Ventilated branches and secondary ventilated stack systems

A ventilating pipe connected to a branch discharge pipe within 750 mm of the trap, which limits pressure changes and protects the seal.

Break cistern

Unit 331Multi-storey supply: the mains limit and the break cistern

A low-level cistern filled from the main through a float valve, from which booster pumps draw. It breaks the connection between the pumps and the main.

Breakdown maintenance

Unit 336Programmes for contract work: new build and maintenance

Maintenance carried out in response to plant having already failed.

Briefing record

Unit 336Using a method statement on site

The signed record showing that each person working under a method statement or risk assessment has received and understood the briefing on it.

Brine

Unit 333Servicing a heat pump: coil, defrost and the water side

The water and antifreeze mixture circulated through a ground collector to carry heat to the heat pump. Its pressure and strength are checked at service.

Brine circuit

Unit 333Filling and venting underfloor circuits and ground collectors

The sealed circuit between the ground collector and the heat pump evaporator, containing the antifreeze mixture. Its pressure is recorded at commissioning as a leak baseline.

British Board of Agrement (BBA)

Unit 332Units, packages, approval and commissioning records

One of the third-party certification bodies whose approval of an unvented unit or package is accepted as evidence that it meets the Building Regulations.

British Standard

Unit 331Design information: the Regulations, notification and BS EN 806

A published set of recommendations for design, materials or workmanship, prefixed BS, or BS EN where it is a European standard adopted in the UK. It is not law, but following it is the accepted way of showing the Regulations have been met and the water undertaker will expect to see it.

BS 1710

Unit 331Approved contractors: certificates of compliance and other notices

The British Standard for identifying the contents of pipes by colour. Water pipes get a green base colour, with an auxiliary blue band for fresh (cold, drinking) water and safety red for fire-fighting water, so non-wholesome pipework can be told apart at a glance.

BS 4800

Unit 331Identifying non-wholesome pipework and testing for cross connections

The British Standard schedule of paint colours, which gives each colour a code. The pipe identification green of BS 1710 is BS 4800 12 D 45.

BS 6700

Unit 331Design information: the Regulations, notification and BS EN 806

The former British Standard for hot and cold water services in buildings, withdrawn when BS EN 806 was completed. Its method and some of its figures, such as the 230 litre cistern minimum and the 3 m/s velocity limit, still appear on older drawings and in older specifications.

BS 6920

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

The British Standard test for the effect of non-metallic materials (plastics, rubbers, coatings, jointing compounds) on water intended for human consumption. It checks taste, odour, appearance, toxic substances and whether the material supports the growth of micro-organisms; a material that passes is suitable for contact with drinking water.

BS 7593

Unit 335Law, standards and schemes: what MCS is and is not

The British Standard for the preparation, commissioning and maintenance of system water in a heating system, including cleaning, flushing and inhibitor.

BS 7671

Unit 331Design information: the Regulations, notification and BS EN 806

The IET Wiring Regulations, the British Standard for electrical installations. It has nothing to do with sizing a cold water pipe, though the numbers look familiar enough to reach for on a mixed-services job.

BS 8000-15

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

The British Standard code of practice for workmanship on hot and cold water services; clause 3.7.6 repeats the location rules for mechanical backflow devices: accessible, inside, not buried, not in a floodable chamber.

BS 8515

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The British Standard for rainwater harvesting systems: their design, installation, water quality, identification of pipework and the need to notify the water supplier before work starts on a site with a mains supply. It also sets out the dry-run protection needed on harvesting pumps.

BS 8525-1

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The British Standard code of practice for greywater systems. It requires greywater pipework to be green or black and green and never blue, storage tanks to be marked, and a flush and air or dye test before handover to prove there is no cross connection.

BS 8558

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The British guide that sits alongside BS EN 806 and gives the UK detail for designing, installing, commissioning and maintaining water services in buildings, including booster sets, cisterns and backflow protection. It replaced BS 6700, which is still quoted for figures BS 8558 no longer gives.

BS 951 earth clamp

Unit 333Testing the finished controls: earth continuity and polarity

The standard clamp used to connect an earthing or bonding conductor to pipework. It carries a permanent label warning that it is a safety electrical connection.

BS EN 12056

Unit 331Design information: the Regulations, notification and BS EN 806

The European standard for gravity drainage systems inside buildings. Like BS 7671 it does not size a cold water pipe, and like BS 7671 it is easy to pick up by mistake.

BS EN 12729

Unit 331RPZ valves and single and double check valves

The European standard for verifiable backflow preventers with reduced pressure zone (family B type A), the standard a type BA RPZ valve is made to.

BS EN 12831

Unit 335Law, standards and schemes: what MCS is and is not

The British and European Standard method for calculating the design heat load of a building.

BS EN 13076

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The European standard for the type AA air gap with unrestricted discharge, the standard BS 8515 cites for a rainwater back-up.

BS EN 13077

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The European standard for the type AB air gap with non-circular (weir) overflow, the standard BS 8515 cites for a closed rainwater or greywater cistern.

BS EN 13959

Unit 331RPZ valves and single and double check valves

The European standard for anti-pollution check valves, the standard single and double check valves are made to. BS 6282-1 was the older British Standard for the same devices.

BS EN 442

Unit 333Emitter load: correcting catalogue output to real conditions

The standard for radiators and convectors. It sets the test reference condition of 75 °C flow, 65 °C return and a 20 °C room, which is an excess of 50 K.

BS EN 806

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The European standard for drinking water installations inside buildings, in five parts: general, design (806-2), pipe sizing (806-3), installation (806-4, which includes pressure testing, flushing and disinfection) and operation and maintenance (806-5). It applies whatever the water source, so private supplies are designed and commissioned to it too.

BS EN 806-2

Unit 331Draining down, standing water and diagnostic readings

The European standard for the design of drinking water installations inside buildings. Its clause 15.3.5.2 limits what a directly connected booster may do to the supply: when the pumps start the pressure must not fall more than 50 per cent below the lowest normal service pressure or below 100 kPa (1 bar), and when they stop the rise must not exceed 100 kPa above the permissible operating pressure.

BS EN 806-3

Unit 331System history: commissioning records, logbooks and inspection frequencies

The European standard for sizing pipework in drinking water installations. Its Table 2 gives the design flow rate and the minimum flow rate for each type of draw-off point, which measured flows are compared against.

BS EN 806-4

Unit 331Galvanic corrosion and the seven steps to handover

The European standard for the installation of drinking water systems inside buildings. Its clause 6 covers commissioning: pressure testing (6.1), flushing (6.2) and disinfection (6.3).

BS EN 806-5

Unit 331RPZ valves and single and double check valves

The European standard for the operation and maintenance of drinking water installations. Its Table A.1 has an RPZ valve inspected every 6 months and maintained once a year, and Annex B forbids bypassing it.

Buffer vessel

Unit 333System volume, buffers and short cycling

An insulated vessel that adds a reservoir of heated water to a system, so the generator has somewhere to put its output and does not cycle.

Builder's work

Unit 336Monitoring progress: readiness, slippage and who to tell

The work another trade does so that the services can be installed: chases, holes, notches, ducts, bases and openings.

building control body

Unit 331Building Regulations Part G: notices and competent person self-certification

The local authority building control department, or an approved inspector, that checks building work complies with the Building Regulations. It must be told before work starts, by full plans or a building notice, inspects the work as it goes, and issues the completion certificate.

Building control officer

Unit 336Running the job: managers, clerk of works and supervisors

An officer of the local authority who checks plans and inspects work to ensure it complies with the Building Regulations.

building notice

Unit 331Building Regulations Part G: notices and competent person self-certification

The simpler way of notifying building control: a short notice with no plans, given before work starts, after which the work is inspected as it goes. It suits small jobs such as a new bathroom.

Building Regulations

Unit 331Design information: the Regulations, notification and BS EN 806

The statutory regulations covering the design and construction of buildings in England and Wales, enforced by building control. Their guidance is published as Approved Documents; Part G covers sanitation, hot water safety and water efficiency.

Building Regulations 2010

Unit 331Building Regulations Part G: notices and competent person self-certification

The law, separate from the Water Fittings Regulations, that sets standards for building work in England and Wales, enforced by the local authority. Part G covers sanitation, hot water safety and water efficiency; most work must be notified to a building control body before it starts unless it is self-certified by a competent person or is minor work listed in Schedule 2B.

Building regulations certificate of compliance

Unit 332Handover: the file, the demonstration and the notices

The certificate given to the building owner or occupier confirming that self-certified work complies with the Building Regulations, usually issued by the competent person scheme operator.

Building Regulations compliance certificate

Unit 331Building Regulations Part G: notices and competent person self-certification

The certificate issued for a completed installation stating that it complies with the Building Regulations, either by the building control body or by a competent person scheme member. It goes in the handover file with the water undertaker's acceptance and the commissioning records.

Building services engineer

Unit 336The design team: architect, engineers and surveyor

The engineer who designs the internal services of a building, such as heating, ventilation and hot and cold water supplies, including heat loss and heat gain calculations.

Building specification

Unit 333Where a heating design starts: the customer's brief

The document recording what is true of this particular building and job, such as its real construction, occupancy and hot water use. Standards supply generic figures; the specification supplies the specific ones.

Building surveyor

Unit 336The design team: architect, engineers and surveyor

A professional who advises on building and property matters, carries out building surveys, writes technical reports and checks that the Building Regulations are followed.

Building work

Unit 334Building Regulation Parts and the notice the law requires for drain work

Work defined by regulation 3 of the Building Regulations, including the erection or extension of a building and the provision, extension or material alteration of a controlled service or fitting.

Buyer

Unit 336Ordering plant and materials, and checking what arrives

The person responsible for sourcing and purchasing the materials a contract needs, obtaining quotes for the quantities required together with delivery times and quality assurances.

Cable saddle

Unit 333Damaged cable: recognising it and putting it right

A metal clip that holds a cable to a surface. Metal saddles or clips are used because non-metallic clips alone are not accepted as support.

calculation sheet

Unit 331Accumulators on a weak main and the calculation sheet

The table that presents a pipe sizing calculation, with a row for each numbered section giving its loading units, design flow, pipe size, velocity, head loss, lengths, and available and residual head. It goes with a numbered line drawing so anyone can check the sizes line by line.

calibrated

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

Checked against a known reference so that its readings can be trusted. A calibrated test gauge or test kit is the reference a fitted gauge, transducer or chlorine reading is compared with.

Calibration

Unit 336The regulations that sit under the Act

Checking and adjusting a test instrument against traceable reference standards, carried out by a calibration house and recorded on a certificate, not done by the operative.

Calmed inlet

Unit 335Rainwater harvesting: collection, filtration and storage

A fitting on the end of the pipe feeding a storage tank that slows the incoming flow, so sediment is not disturbed and the water is not aerated.

Calorific value

Unit 335Comparing the technologies: carbon, cost and customer fit

The energy released by burning a stated quantity of fuel. Natural gas carries roughly 10.4 kWh per cubic metre, which is how a heat saving is converted into a fuel saving.

Calorifier

Unit 332Design temperatures: storage, flow, return and outlet

A vessel in which water is heated indirectly by a heat exchanger. The word is used in the standards for what is commonly called a hot water storage cylinder.

cap off

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

Sealing every open pipe end with a proper cap, blank or plug before leaving the job, however briefly, so that nothing can enter the pipework and no water escapes if the supply is restored. Rag pushed into the end, or a valve left slightly open, is not acceptable.

Capability procedure

Unit 336Dealing with poor work: informal action and the formal procedure

The employer's formal process for handling work that repeatedly falls below the required standard: written notice, a meeting, a decision and an appeal.

capacitor

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

A component in a single-phase pump motor that stores an electrical charge and gives the motor the phase shift it needs to start and run. A failed capacitor is a common reason for a single-phase motor that hums or will not run.

Capillary attraction

Unit 334The six causes of trap seal loss, and how to tell them apart

Loss of a trap seal caused by a strand of hair or fibre lying over the weir of the trap, which draws the water out drop by drop.

Capillary joint

Unit 331Visual inspection: the documents and the dry checklist

A soldered joint in which solder is drawn into the gap between pipe and fitting. A dry joint is one where the solder has not run.

Capital cost

Unit 335Air source heat pumps: the benefits and where they struggle

The one-off cost of buying and installing a system, as distinct from the cost of running it afterwards. Micro-renewable systems typically have a high capital cost and a low running cost.

Carbon emission factor

Unit 335Comparing the technologies: carbon, cost and customer fit

The mass of carbon dioxide released per kilowatt-hour of a given fuel, used to compare systems fairly. Approved Document L 2021 (SAP 10.2) gives 0.210 kg per kWh for natural gas and 0.136 for grid electricity.

Carbon filter

Unit 334Macerators and waste disposal units: what commissioning must prove

The activated charcoal element on a macerator's air valve that absorbs odours. It saturates in use and is replaced at the manufacturer's interval.

Cascade

Unit 335Monovalent, bivalent systems, buffers and system volume

Two or more heat pumps of the same kind connected to work together on one system to meet a larger load.

cathode

Unit 331Galvanic corrosion and the seven steps to handover

In a galvanic cell, the more noble metal, which receives the current and is protected from corrosion — copper in contact with zinc or steel, for example.

Caution notice

Unit 333Notifying the client, safe isolation and temporary decommissioning

The warning label placed at the point of isolation stating that the system is off and must not be switched on.

Cavitation

Unit 331Balancing, mechanical controls and functional testing

Vapour bubbles forming and collapsing in a pump, heard as a rattling noise; listened for during functional testing.

Centralised hot water system

Unit 332Centralised and localised hot water: choosing between them

A system in which water is heated at one central point and distributed by pipework to all the hot outlets in the dwelling.

Centrifugal pump

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A pump in which a spinning impeller throws water outwards to raise its pressure. All booster pumps are this type.

certificate of compliance

Unit 331Approved contractors: certificates of compliance and other notices

The signed document an approved contractor must give the person who commissioned the work on completion, under Regulation 6, stating that the fittings comply with the Water Fittings Regulations. A copy goes to the water undertaker where the work was notifiable, and the owner keeps it as their statutory defence.

Cesspool

Unit 334Cesspools and septic tanks: how they work and what they need

A watertight underground tank with an inlet and no outlet, used to store sewage until it is emptied by a licensed contractor. No treatment takes place.

Chain of command

Unit 336The chain of command: who can give you an instruction

The formal reporting line on a job showing who may give instructions and to whom problems are reported. Instructions travel down it and issues travel up it.

Change control

Unit 336Variations: what counts as a change to the contract

The documented route by which a proposed change is recorded, authorised and priced before it is carried out.

Charge pressure

Unit 332Sizing pumps and expansion vessels

The pressure of the gas behind the diaphragm of an expansion vessel when there is no water in it, normally set to the pressure the system sits at when cold. Raising it reduces the expansion the vessel can accept.

Charge-out rate

Unit 336Building a price: a worked example

The hourly rate a company charges for an operative's time, which is higher than the wage because it has to help carry the company's costs.

Charging the seals

Unit 334Setting up the air test: plugs, manometer and charged traps

Filling every trap on the system with water before a test, so that no trap is an open path for air.

check valve (non-return valve, NRV)

Unit 331Sources of fault information: the end user and the manufacturer

A valve that lets water flow one way only and closes against reverse flow. On a booster set one sits on each pump discharge; if the standby pump’s valve fails, water recirculates through the idle pump instead of reaching the outlets.

CHeSS

Unit 333Boiler interlock, CHeSS and signing the work off

The Central Heating System Specification, CE51 2008, which sets out good practice and best practice packages of heating controls for domestic systems.

Circuit identification label

Unit 333Supplying and isolating the controls on site

A durable label at an accessory or protective device stating what it supplies or isolates, as required by Regulation 537.2.7.

Circuit protective conductor (cpc)

Unit 333Earthing and bonding a heating control circuit

The conductor that connects the exposed metalwork of equipment on a circuit back to the main earthing terminal, so that a fault current can flow and the protective device can operate.

Circulating pump

Unit 333The circulating pump: position, isolating valves and unions

The pump that moves water round the heating circuits. Its duty is chosen from the pressure loss of the index circuit plus any pressure drop through the boiler.

Circulation space

Unit 334Activity space: sanitary accommodation people can use

The area free of obstruction required for access to an appliance without interfering with the users of other appliances.

Cistern inspection

Unit 331After handover: signing off and the routine user checks

The routine check of a stored-water cistern for cleanliness, contamination and general condition: annually, under BS 8558 clause 6.1.5.1, BS EN 806-5 clause 12 and HSE HSG274 Part 2, and sooner if fouling, debris or vermin are found. Not to be confused with the six-monthly sampling of stored drinking water in BS 8558 clause 6.1.4.1.

cistern refill flow

Unit 331Cistern sizing, float valve refill and pipe design limits

The flow the float-operated valve needs to refill a cistern in the required time: capacity divided by filling time in seconds. A dwelling's cistern should refill in under an hour (the withdrawn BS 6700's figure, still the usual one), up to four hours where nothing else is known (BS 8558); a 320 litre cistern in an hour needs 320 ÷ 3 600 = 0.09 l/s, which is added to the loading unit flow when the supply pipe is sized.

cistern-fed system

Unit 331Available pressure and flow, feed arrangements and loading units

A cold water system in which a storage cistern, usually in the loft, feeds the outlets and the hot water cylinder through distributing pipes under the head the cistern gives. Also called an indirect system; the kitchen sink stays on the supply pipe so drinking water is wholesome.

Civil engineer

Unit 336The design team: architect, engineers and surveyor

The engineer who designs roads, bridges and tunnels serving a building, and is often involved in the drainage and water requirements to the site.

Class I equipment

Unit 333Earthing and bonding a heating control circuit

Equipment whose protection against electric shock relies on basic insulation plus a connection of its exposed metalwork to a protective conductor. A circulating pump is normally Class I.

Cleaning eye

Unit 334Traps, seals and appliances: the checks before you test

A removable cap on a trap or fitting that gives access to clear a blockage without taking the whole trap off.

Cleanser

Unit 333Cleansers, neutralisers, inhibitors and the in-line filter

A chemical formulated for heating systems that lifts and disperses mineral oils, flux residues, sludge and scale so that flushing can carry them out.

Cleansing flush

Unit 331Flushing: the legal order and the BS EN 806-4 method

A flush of an existing system after non-use, new components or possible contamination, as listed in PD 855468 clause 6.1.

Clerk of works

Unit 336Running the job: managers, clerk of works and supervisors

The client's representative on site for quality. Checks and verifies the work as it is completed against the drawings and specification and keeps written records of sample checks.

Client-supplied materials

Unit 336Materials changes: substitutions, discrepancies and damaged goods

Materials or appliances bought by the client rather than by the contractor. They are inspected, accepted or rejected in exactly the same way as the contractor's own.

clip-on ammeter (clamp ammeter)

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

A meter whose jaws clamp round one conductor to read the current flowing in it without breaking the circuit. A running current above the manufacturer’s figure points to loose connections, a shorted winding, burned starter contacts or a damaged pump.

Closed loop collector

Unit 335Ground source heat pumps: the four collector types

A sealed circuit of buried pipe carrying a water and antifreeze mixture, which exchanges heat with the ground without taking any water from it.

Closed-cell insulation

Unit 335Installing to the standards: pipework, penetrations and insulation

Insulation whose cells are sealed from one another so it does not absorb water. It is used outdoors, with protection against ultraviolet light.

Coarse strainer

Unit 331Private water supplies: sources and responsibilities

A screen on a stream intake that keeps out fish, weed, silt and debris, giving the supply its first protection.

code band

Unit 331Identifying non-wholesome pipework and testing for cross connections

A band of colour painted or taped on a pipe, about 150 mm long, at valves, junctions and where the pipe passes through walls and floors, to identify what it carries. The basic colour is shown either side of a code colour, so a reclaimed water pipe reads green, black, green.

Code of practice

Unit 334Interpreting the information before commissioning starts

A British or European Standard that recommends how work should be designed, installed or tested. BS EN 12056 and BS 8000-13 are codes of practice for drainage.

Coefficient of performance (COP)

Unit 332Efficiency, carbon and cost: what the heat source decides

The ratio of useful heat delivered by a heat pump to the electrical energy it consumes at a given moment. A COP of 3 means three units of heat for one of electricity. A direct electric immersion has a COP of 1.

Cold feed

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

The pipe that drops from the feed and expansion cistern to fill the heating system and to allow expansion back into the cistern.

Cold feed pipe

Unit 332Vented hot water storage: cold feed, vent and layout

The pipe from the cold water storage cistern to the bottom of the hot water storage vessel. It supplies the cylinder only, and it is the route up which expanded water rises.

Cold fill pressure

Unit 333The filling loop, backflow protection and the cold fill pressure

The pressure a sealed system is set to when it is cold, normally about 1 bar. It is read on the system pressure gauge.

Cold flush

Unit 333Cold flushing, hot flushing and the power flush

Draining and emptying a filled system after the soundness test to carry out loose installation debris before the system is refilled.

Cold water accumulator

Unit 332Supply pressure and flow, and where the pipes run

A pressurised vessel that stores mains water when the supply pressure is at its highest and releases it during periods of demand, improving both flow and pressure.

cold water storage

Unit 331Cistern sizing, float valve refill and pipe design limits

The volume of cold water held in a cistern to cover peak demand and interruptions. BS EN 806-2 gives 80 litres per person for a dwelling with a constant supply, 130 litres per person where it refills only at night; the withdrawn BS 6700 set a 230 litre minimum for a cistern feeding both cold outlets and the cylinder, and at least the cylinder's capacity for one feeding the cylinder alone, still used as rules of thumb.

Cold water storage cistern (CWSC)

Unit 332Vented hot water storage: cold feed, vent and layout

The open topped vessel that stores cold water above the outlets and feeds the hot water cylinder in a vented system. Its height gives the pressure at the taps.

Collection area

Unit 335Rainwater harvesting: the savings and the strings attached

The plan area of the roof or other surface drained to a rainwater harvesting system. It sets the ceiling on how much water the system can ever supply.

Collector

Unit 333Servicing a heat pump: coil, defrost and the water side

The buried pipework, in trenches or boreholes, through which a ground source heat pump absorbs heat from the ground.

Combination bath tap and shower head

Unit 332Specialist taps and outlet fittings: how they work

A bath/shower mixer tap, made in pillar, deck, thermostatic and wall mounted patterns, requiring comparable hot and cold pressures.

Combination boiler

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

A dual function appliance providing central heating and instantaneous hot water from one case, with no cylinder or cistern.

Combination cylinder

Unit 332Direct, indirect and combination cylinders compared

A cylinder with its own cold water cistern built on top as a single unit, with factory-fitted cold feed and vent. Known as a Fortic.

combined pressure and flow meter

Unit 331Draining down, standing water and diagnostic readings

An instrument screwed onto an outlet that reads static pressure, running pressure and flow rate in one operation.

Combined primary storage unit

Unit 332Thermal stores and solar thermal: their pipework layouts

A thermal store with its own gas burner built in, heating the primary water directly so that no separate boiler is required.

Combined system

Unit 334Sanitary pipework: the rules and the standard sizes

A below ground drainage arrangement in which foul water and surface water are carried in the same sewer to the treatment works.

Combined temperature and pressure relief valve (T&P)

Unit 332Three levels of safety on an unvented cylinder

A single valve that acts on both temperature and pressure, used on most unvented vessels in place of a separate temperature relief valve.

commissioning

Unit 331Approved contractors: certificates of compliance and other notices

The final stage of an installation in which the system is filled, tested, flushed, disinfected where needed, adjusted and checked for correct working before it is handed over, with the results recorded. Notice that commissioning is complete goes to building control and to the customer.

commissioning certificate

Unit 331Identifying non-wholesome pipework and testing for cross connections

The written record completed at handover of the tests carried out, their results and the settings of the installed equipment. The dye test on a greywater or rainwater system is recorded on it.

Commissioning notice

Unit 333Boiler interlock, CHeSS and signing the work off

The notice of completion of commissioning given to the building control body confirming that a fixed building service has been commissioned.

commissioning record

Unit 331System history: commissioning records, logbooks and inspection frequencies

The written record of what a system did when it was first put to work: the type and duration of the pressure test, disinfectant concentration and contact time, flow rates and pressures at the outlets, pump suction and discharge pressures and the accumulator pre-charge. It is the baseline later faults are measured against and forms part of the system history.

Common branch discharge pipe

Unit 334Traps, seals and appliances: the checks before you test

A branch pipe serving more than one appliance before it reaches the stack. Traps on it are exposed to induced siphonage from the other appliances.

Comparator

Unit 331Disinfection: which jobs need it and what disinfectant is used

A calibrated test kit that changes colour with chlorine strength, used to read the residual (PD 855468 clause 10.1.6).

Compartment floor

Unit 334Fire stopping, access and notification

A floor built to a fire resistance rating that divides a building into separate fire compartments, for example the floor between two flats.

Compensation curve

Unit 333Weather compensation, optimum start and home automation

The relationship the compensator follows between outside air temperature and flow temperature. Set as low as the building allows and then proven in cold weather.

Competence

Unit 333Manufacturer instructions, fault codes and flow charts

Having the training, knowledge, skill and experience to carry out a task safely and correctly. Authorisation is the separate question of whether you are permitted to.

competent person scheme

Unit 331Building Regulations Part G: notices and competent person self-certification

A government-recognised scheme whose registered members can self-certify their own work as complying with the Building Regulations instead of notifying building control. For installing a wholesome cold water supply the listed schemes are APHC, BESCA, CORGI, NAPIT and NICEIC; the member gives the occupier a certificate within 30 days and notifies the building control body in the same time.

Competent person self-certification scheme

Unit 331Regulation 5 notification and the certificates of compliance

A scheme whose members certify their own building work, giving the occupier a certificate within 30 days and notifying building control themselves.

completion certificate

Unit 331Building Regulations Part G: notices and competent person self-certification

The certificate a building control body issues when notified work has been inspected and found to comply. For a new dwelling it cannot be issued until the water efficiency calculation has been received.

Composite valve

Unit 332Composite valves, vacuum relief and anti-legionella valves

A single valve body containing several of the inlet control group components in their correct order, usually the strainer, pressure reducing valve, balanced cold take-off, check valve and expansion relief valve.

Compression

Unit 334Why trap seals are performance tested: siphonage and compression

Loss of a trap seal caused by positive pressure. Water falling down a stack compresses the air below it and blows a low-level seal back up into the appliance. Also called back pressure.

Compression joint

Unit 331Visual inspection: the documents and the dry checklist

A mechanical joint tightened onto an olive that grips the pipe. A missing olive is a classic visual-inspection find.

Compressor

Unit 335Heat pumps: how the refrigeration cycle moves heat

The pump that raises the pressure and temperature of the refrigerant vapour. It is the only part of the cycle that consumes electrical power.

Concealed work

Unit 334The visual inspection: what a completed system must show

Pipework that will be hidden by boxing, ducts, screeds or finishes. It must be inspected and tested before it is enclosed.

Condensate trap

Unit 334Joining branches to the stack: cross-flow and the no connection zone

A 75 mm seal trap through which boiler condensate is discharged into sanitary pipework. The pipework must resist a pH of 6.5 and lower.

Condenser

Unit 333Heat pump fault patterns: temperature difference and pressures

The heat exchanger in which the refrigerant gives up its heat to the heating water. Poor water flow through it raises the condensing pressure.

Condition-based maintenance

Unit 336Programmes for contract work: new build and maintenance

Maintenance triggered by measurements or inspections showing the condition of the plant, rather than by a fixed interval.

conditions

Unit 331Regulation 5 notification: the list and the ten working days

Requirements a water undertaker may attach when it consents to notifiable work, such as a particular backflow device or an inspection before pipework is covered. Regulation 5(1)(c) requires them to be complied with; breaching a condition is an offence like starting without consent.

Conduit sleeve

Unit 333Laying the underfloor pipe: centres, fixing and joints

A protective sleeve fitted over the pipe where it crosses a screed joint or threshold, so the two slabs can move without shearing the pipe.

Consequence

Unit 336Ranking the risk: likelihood times severity

The judged seriousness of an accident if it happens, scored from no injury or loss through first aid and lost-time injuries to fatality.

Conservation area

Unit 335Permitted development: what it means, and solar on a roof

An area designated for its special architectural or historic character, where extra planning controls apply. Permitted development still applies there, with tighter conditions.

Constructed wetland

Unit 334Cesspools and septic tanks: how they work and what they need

A man-made bed of wetland plants, such as a reed bed, that uses the plants' natural treatment capacity to polish septic tank effluent.

Construction (Design and Management) Regulations 2015 (CDM)

Unit 336CDM 2015: duty holders, domestic clients and induction

The principal health and safety regulations for construction work. They set duties for the client, principal designer, principal contractor, contractors and workers, and apply to all construction work including domestic work.

Construction manager

Unit 336Running the job: managers, clerk of works and supervisors

The contractor's main representative on site, responsible for its day-to-day running, including budgets, staffing, deliveries and progress.

Construction phase plan

Unit 336CDM 2015: duty holders, domestic clients and induction

The written plan setting out how health and safety will be managed during the construction phase, together with the site rules.

Construction Skills Certification Scheme (CSCS) card

Unit 336Types of client: private, contracting and internal

A card carried on site confirming that the holder has the training and qualifications claimed. Contracting customers normally require one before allowing access.

Consumable part

Unit 334Running the macerator: cycle, leaks, faults and handover

A component expected to be replaced at intervals through the life of an appliance, such as a macerator's carbon filter, rather than lasting the life of the unit.

Consumer unit

Unit 333Checking the existing circuit: rating, condition and damage

The board at the origin of a domestic installation holding the main switch and the circuit protective devices for the final circuits.

Contact period

Unit 332Disinfection: when it is needed and the figures

The time the disinfectant is held in the system at its initial concentration. It starts only when the whole system, cisterns included, is filled at that concentration.

Contact time

Unit 331Chlorine disinfection: the figures, the people and the samples

The period the chlorinated water is left in the system, at least one hour from when the whole system is at 50 mg/l, longer at high pH.

contamination

Unit 331The Water Regulations: origin, enforcement and the five harms

Any reduction in the chemical or biological quality of the water, whether by a change of temperature or by a polluting substance getting into it (Schedule 2 paragraph 1). Backflow from a hose left in a bucket of disinfectant is the classic example; a change that only affects taste, such as softening, is not contamination.

Contingency plan

Unit 336Project delays and contingency planning

A plan prepared in advance for a foreseeable problem, so that work can continue with the least loss of time and money when it happens.

Continuity of protective conductors

Unit 333Polarity and earth continuity: what each test proves

A measurement of resistance proving there is an unbroken low-resistance path along every protective and bonding conductor back to the main earthing terminal.

Continuity of work

Unit 336Monitoring progress: readiness, slippage and who to tell

Having enough uninterrupted work available for the gang to keep going once they have started, rather than stopping and returning.

Continuity test

Unit 334Commissioning a WC macerator: the checks before power on

A measurement of resistance along a conductor to prove it is unbroken. It is used to find an open circuit and is carried out dead.

Contract

Unit 336Contract types: fixed cost, variable cost and cost plus

The agreement between the parties setting out the work to be done, the price, the time allowed and how changes will be handled.

Contract administrator

Unit 336Variations: what counts as a change to the contract

The person named in a construction contract to administer it on the client's behalf, including issuing instructions and valuing changes. Often the architect.

Contract programme

Unit 336Work programmes: what they are and what they show

The overall schedule for a contract, showing when each part of the work must be done and the target completion dates.

Contracting customer

Unit 336Types of client: private, contracting and internal

A business or organisation that engages a plumbing firm under a contract to carry out work for it. On a construction site this is normally the main contractor.

Contracts manager

Unit 336Running the job: managers, clerk of works and supervisors

The manager who supervises the creation and management of building contracts, liaising between head office staff and the site agents.

Contractual authority

Unit 336Variations: what counts as a change to the contract

The power to instruct a change to the contract. It rests with the paying customer on a private job, or with the person the contract names, such as the architect or contract administrator.

Control box

Unit 331Borehole pumps: packaged sets, controls and the accumulator

The electronic controller on a small packaged booster set that reads the transducer, starts and stops the pump and may vary its speed to hold the pressure steady.

Control measure

Unit 336Control measures and the hierarchy of control

Anything put in place to remove a hazard or reduce the risk from it, such as a guard, a barrier, a safe system of work or protective equipment.

Control of Substances Hazardous to Health Regulations (COSHH)

Unit 336The regulations that sit under the Act

Regulations requiring employers to assess the risk from hazardous substances and to prevent or adequately control exposure to them.

Control panel

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The electrical panel on a booster set that starts and stops the pumps in sequence from the transducer or switch signals.

Control thermostat

Unit 332Three levels of safety on an unvented cylinder

The thermostat that holds the stored water at its working temperature of 60 to 65 degrees C. On a direct system it is the immersion heater thermostat; on an indirect system it is the cylinder thermostat.

Controlled service or fitting

Unit 334Building Regulation Parts and the notice the law requires for drain work

A service or fitting subject to the Building Regulations, such as drainage, sanitary pipework, hot water or heating equipment. Providing or altering one is building work.

Convection

Unit 333Radiators: fixing height, brackets and valve connections

Heat carried by moving air. Cool air is drawn in under the radiator, warmed by the fins and rises off the top as a warm current.

Cooling leg

Unit 335Stagnation: the limitation designed into every solar system

A deliberately uninsulated length of pipework, typically on the connection to the expansion vessel, that lets hot fluid and vapour lose heat before reaching a temperature-sensitive component.

Correction factor

Unit 333Emitter load: correcting catalogue output to real conditions

The multiplier that converts a radiator's catalogue output at the reference condition to its output at the actual mean water temperature and room temperature. Catalogue output equals heat loss divided by the factor.

Corrective maintenance

Unit 336Programmes for contract work: new build and maintenance

Work done to put right a fault that has been identified, before or after it causes a failure.

Corrosion inhibitor

Unit 333Cleansers, neutralisers, inhibitors and the in-line filter

The chemical left permanently in the system water to minimise corrosion of the metals and to inhibit the formation of magnetite sludge and limescale.

COSHH Regulations

Unit 334Blockages: where they form and how they are cleared

The Control of Substances Hazardous to Health Regulations, which govern the use of chemicals such as descaling acids on site.

Cost plus contract

Unit 336Contract types: fixed cost, variable cost and cost plus

A contract under which the contractor is reimbursed the actual cost of labour, materials and plant, plus an agreed fee or percentage.

Cover letter

Unit 336Quotation, estimate and tender: presenting the price

The short letter or email sent with a quotation, saying what is attached, what it covers, the price and timing, and how to respond.

Creep

Unit 331Soundness testing: test pressures for metal and plastics pipework

The slow stretching of plastics pipe under sustained pressure, largest at first and tailing off as the material settles into its new shape.

critical level

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

The highest level water can reach in a cistern with the float-operated valve failed fully open and the overflow or weir running at full bore. A type AG or AB air gap is measured down to this level, not to the normal water line.

Critical path

Unit 336Reading a bar chart: a worked example

The chain of dependent activities that determines the total duration of a project. Delay to any activity on it delays the whole job.

Critical path method

Unit 336Programmes for contract work: new build and maintenance

A way of programming work that identifies the chain of activities determining the total duration of the project, so delay to any of them delays the whole job.

cross connection

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

A physical link between wholesome water and water that is not wholesome: rainwater, greywater, a private supply, a heating circuit or the hot side of a mixer. Under Schedule 2 paragraph 14 the connection itself is an offence, whether or not anything flows through it; a closed valve or a hose dropped into a tank is still a connection.

cross-connection

Unit 331Scope of the Regulations: mains supplies in, private supplies out

Any pipe or fitting that could let water from another source, such as a private supply, rainwater, greywater or a heating system, reach the wholesome mains supply. Schedule 2 paragraph 14 forbids it outright and requires non-wholesome pipework to be clearly identified; it is the one rule that applies even to private supplies.

Cross-contamination

Unit 335Greywater re-use: a steadier supply, a heavier burden

The accidental connection or backflow that lets non-potable water enter a wholesome water supply. It is the principal health risk of any re-use system, and is guarded against by air gaps, marking and testing for cross-connections.

Cross-flow

Unit 334Joining branches to the stack: cross-flow and the no connection zone

The discharge from one branch pipe crossing the stack and entering another branch, instead of falling down the stack.

Cross-sectional area (csa)

Unit 333Choosing and routing cable for heating controls

The area of the copper in a conductor, quoted in square millimetres. It determines how much current the conductor can carry and how much it will drop in voltage.

Crossflow

Unit 334Branch discharge pipes: diameter, length and gradient

Discharge from one branch pipe flowing across the stack and into the opening of another branch opposite, instead of down the stack.

Curing

Unit 333The pressure test, the pour and the 21 day cure

The chemical hardening of a screed after it is poured, which takes time and depends on the screed keeping its moisture. Heat must not be used to speed it up.

cut-in and cut-out pressure

Unit 331Booster set controls: accumulator, pressure switch and float switch

The two settings on a pressure switch: cut-in is the falling pressure at which the pump starts, cut-out the rising pressure at which it stops. Both are checked against a calibrated gauge and the commissioning figures.

Cut-in pressure

Unit 331Booster sets: the pressure vessel and the control switches

The pressure at which the low pressure switch starts the pumps as water is drawn.

Cut-off ditch

Unit 331Private water supplies: sources and responsibilities

A ditch dug upslope of a spring chamber to carry surface run-off around it instead of into it.

Cut-out pressure

Unit 331Booster sets: the pressure vessel and the control switches

The pressure at which the high pressure switch stops the pumps once the system is up to pressure.

Cutting template

Unit 334Manufacturer data, fault charts and documented history

A full-size pattern supplied by a manufacturer to mark out a cut-out, for example the hole in a worktop for a countertop wash basin.

Cycling

Unit 333Heat pump fault patterns: temperature difference and pressures

Repeated short runs and stops of a heat source, caused by reaching setpoint too quickly. It wastes energy and wears components.

Cylinder thermostat

Unit 332Thermostats, cut-outs, programmers and motorised valves

The control that senses stored water temperature and switches the heat source off at the set temperature. It provides normal operating control, not safety.

D1 discharge pipe

Unit 332Discharge pipework: the tundish, D1 and D2

The short metal pipe from the relief valve to the tundish, no smaller than the valve outlet and no longer than 600 mm.

D2 discharge pipe

Unit 332Discharge pipework: the tundish, D1 and D2

The pipe from the tundish to the point of discharge, at least one size larger than the valve outlet, with 300 mm of vertical pipe before any bend and a continuous fall thereafter.

Daily hot water allowance

Unit 332Working out the daily hot water demand for a dwelling

The volume of hot water a design assumes each occupant uses in a day, quoted at a stated temperature. Around 45 litres per person per day at 60 degrees is the usual mixed-use figure.

damaged, worn or otherwise faulty

Unit 331Regulations 3 and 4: installer tests and user duties

The words of Regulation 3(3): a fitting in that condition which is likely to cause one of the five harms must not be used. It is the rule that makes the owner or occupier responsible for maintaining fittings, not just the installer for fitting them.

Damp proof membrane (DPM)

Unit 333Floor insulation and the layers before the screed

The sheet layer in a ground floor that stops moisture rising from the ground. In an underfloor build-up the insulation sits above it.

data plate

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

The plate on a pump or motor giving its rated duty, pressure, current and voltage. Readings taken in service are compared with the data plate figures.

Datum reading

Unit 334Applying the air test and reading the result

The zero reading taken on the manometer before pressure is applied. Every later reading is compared against it.

Daywork sheet

Unit 336Variations: what counts as a change to the contract

A record of the hours, materials and plant used on work that is charged at agreed rates rather than being covered by the contract price. It is only worth anything if the work was instructed.

dB(A)

Unit 335Heat pumps and permitted development: volume, boundary and noise

A sound level in decibels, weighted to match how human hearing responds. MCS 020 a) sets the domestic heat pump limit at 37 dB LAeq,5mins, the A-weighted level averaged over five minutes.

De-jamming tool

Unit 334Sink waste disposal units: jams, overloads and blockages

The purpose-made tool supplied with a disposal unit for freeing the grinding blades. It is only used with the supply safely isolated.

dead leg

Unit 331RPZ valves and single and double check valves

A length of pipe in which water does not move because the outlet it serves is rarely or never used. Stagnant water in it can warm, lose its chlorine and grow bacteria, so dead legs are avoided in design; where one is unavoidable a single check valve stops it feeding back.

Dead load

Unit 335Roof structure and area: load, wind uplift and calculation

The permanent weight a structure carries, including its own materials and anything fixed to it such as collectors and their mountings.

Dead test

Unit 333Dead tests and live tests: the order and the instruments

A test carried out with the circuit isolated and proved dead. Continuity, insulation resistance and polarity are all dead tests.

Decanting

Unit 336Substances on site: data sheets, glycol and spills

Transferring a substance from its original container into another. It must never be done into an unmarked container, because the hazard information is lost.

decommissioning

Unit 331Galvanic corrosion and the seven steps to handover

Taking a component or section out of service safely: relieving the pressure, draining with air admitted, capping the open ends and disconnecting it. Where something is removed for good, the pipe is cut back to the live main to avoid a dead leg.

Dedicated circuit

Unit 333Supplying and isolating the controls on site

A circuit run from the consumer unit that supplies one item of equipment or one system only, with its own protective device.

Defect

Unit 331The commissioning record and the defects that go on it

Any failure found during commissioning, from a leak to a wrong component, corrected immediately and retested before further work proceeds.

Defective workmanship

Unit 336Project delays and contingency planning

Work that does not meet the specified standard and has to be taken out and redone, delaying everything that depends on it.

Defects period

Unit 336Accepting finished work: snagging, records and handover

The period after practical completion during which the building is in use and any agreed or newly emerged defects are put right, usually before final payment is released.

Deficiency

Unit 336Dealing with poor work: informal action and the formal procedure

In work performance, a problem that affects safety, quality or cost effectiveness, such as incorrectly specified pipework or unsafe installation.

Defrost cycle

Unit 333Setting the controls: flow temperature, hot water and defrost

The operation in which an air source unit reverses its cycle to melt ice off the outdoor coil. It must start and stop correctly and the meltwater must drain away.

Delayed action float valve

Unit 331Large cisterns: warning pipes, overflows and inlet valves

An inlet valve that stays shut until the cistern level falls to a pre-set point, then opens fully for a fast fill. The Keraflo or Aylesbury type.

Delayed start

Unit 333Weather compensation, optimum start and home automation

A control function that compares actual room temperature with the temperature required at the programmed start time and delays firing the boiler if the house is already close.

Delegation

Unit 336Craft levels and allocating work: who supervises whom

The sharing or transfer of authority and responsibility from an employer or supervisor to an employee for a particular task.

Delivered temperature

Unit 332Working out the daily hot water demand for a dwelling

The temperature hot water is actually used at, taken as 45 degrees for design. It is lower than the storage temperature because water is blended at the outlet.

Delivery note

Unit 336Ordering plant and materials, and checking what arrives

A document listing the type and quantity of materials delivered to site. It is checked against the goods and signed only if the two agree.

Demonstration

Unit 331Handover: the file and the demonstration

The part of handover in which the customer is walked round the system, shown how the controls work and how to isolate the supply, and allowed to do it themselves.

Dependency

Unit 336Monitoring progress: readiness, slippage and who to tell

A link between two activities on a programme, where one cannot start or finish until the other has reached a certain point.

Depth of water seal

Unit 334Smells and slow running: what each complaint points to

The vertical depth of water held in a trap, measured in millimetres. Approved Document H requires at least 25 mm to be retained under working and test conditions.

Derating factor (fT)

Unit 332Soundness testing to BS EN 806-4: procedures A, B and C

A factor supplied by the pipe manufacturer, applied to the test pressure when the equilibrium temperature of a plastics pipe system is above 25 degrees C.

Descaling

Unit 334Blockages: where they form and how they are cleared

Removing lime scale from pipework, usually with a diluted, inhibited acid-based fluid applied at set points or by drip feed, followed by thorough flushing with clean water.

Design brief

Unit 333Where a heating design starts: the customer's brief

The record of what the customer wants from the system: rooms heated, temperatures, running hours, hot water demand and budget. It is agreed before calculation begins.

Design drawing

Unit 331Handover: the file and the demonstration

The drawing showing what was intended; often overtaken on site and not the drawing handed over.

Design engineer

Unit 331The commissioning record and the defects that go on it

The person responsible for the design and pipe sizes, consulted when flow or pressure falls short because the pipes look too small.

Design flow

Unit 333Heat pump fault patterns: temperature difference and pressures

The flow rate a circuit was designed to receive. A circuit that is not getting it will underperform however good the heat source is.

design flow rate

Unit 331Available pressure and flow, feed arrangements and loading units

The flow an outlet should receive when it is the only one discharging, in litres per second. BS EN 806-3 Table 2 gives 0.1 l/s for a basin or WC cistern, 0.2 l/s for a sink or shower, 0.3 l/s for a urinal flush valve, 0.4 l/s for a bath and 0.5 l/s for a garden tap.

Design flow temperature

Unit 333Flow temperature: the number that governs running cost

The temperature the system is designed to send to the emitters at the design condition. It sets the emitter sizes and, on a heat pump, largely sets the running cost.

Design heat load

Unit 333Total heat load, hot water load and the boiler size

The total heat a building needs at the design condition: the sum of the design heat losses of every heated space plus the capacity needed to warm up after an off period. It sizes the heat generator.

Design heat loss

Unit 333Working a room: a fabric and ventilation heat loss

The total heat a room or building loses at the design condition, being fabric loss plus ventilation loss, before any allowance for warm-up is added.

Design return temperature

Unit 333Flow temperature: the number that governs running cost

The temperature the water is designed to arrive back at the generator. Keeping it below about 55 °C is what allows a gas condensing boiler to condense.

Design temperature drop

Unit 333One-pipe, two-pipe and reverse return layouts

The intended difference between the flow and return water temperatures at design conditions. BS EN 12828 gives 10 °C for a conventional system.

detail drawing

Unit 331Design information: manufacturer data, customer feedback and scale plans

A large-scale drawing, at 1:20, 1:10 or 1:5, of one part of a building such as a bathroom or plant area, showing what a floor plan is too small to show. Also called a part plan.

Dew point

Unit 333Flow temperature: the number that governs running cost

The temperature at which vapour in a gas begins to condense. Natural gas flue products have a dew point around 55 °C, which is the basis of the condensing boiler return limit.

dezincification

Unit 331Galvanic corrosion and the seven steps to handover

The corrosion of ordinary brass in which the zinc is leached out, leaving a weak, porous, reddish copper skeleton that cracks. It shows as a white powdery zinc oxide on the fitting.

dezincification-resistant

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

Dezincification is the corrosion of ordinary brass in which the zinc leaches out and leaves a porous copper skeleton that keeps its shape, shows no symptom and then fails suddenly. Dezincification-resistant (DZR) brass is an alloy treated so that it does not do this, proved by the BS EN ISO 6509 test and marked CR or DRA; exam answers quote a resistant depth of at least 200 microns.

dezincification-resistant brass (DZR)

Unit 331Galvanic corrosion and the seven steps to handover

Brass alloyed and heat-treated so that it does not lose its zinc in aggressive water. Grade A dezincification-resistant fittings are marked CR (corrosion resistant) or DRA, and CR is the marking to look for.

Diagnosis

Unit 333Gathering information from the end user before you test

The process of working from the symptoms and the evidence to the actual cause of a fault, and proving that cause before anything is replaced.

diagnostic checks

Unit 331Draining down, standing water and diagnostic readings

Measurements taken on a working system — pressures, flow rates, currents, resistances — and compared with the commissioning record and the manufacturer’s data, so that the fault is located by the difference rather than by guesswork.

diagnostics flow diagram (fault-finding chart)

Unit 331Sources of fault information: the end user and the manufacturer

A flow chart in the manufacturer’s operation and maintenance instructions that leads you through a fault step by step, each box asking one question and the chart starting with the cheapest and most likely cause.

Diaphragm

Unit 332Expansion vessels and air gaps: checking and recharging

The flexible membrane or bladder that separates the water from the gas charge inside an expansion vessel. If it ruptures the vessel waterlogs and can no longer take up expansion.

Diaphragm type expansion vessel

Unit 332Expansion on an unvented system: vessel, valve and balanced cold

An expansion vessel in which a diaphragm separates the water from the gas charge, with the water lying against the steel shell. Used on sealed heating systems, not on unvented hot water.

differential pressure

Unit 331Backflow devices: testing check valves and maintaining the RPZ valve

The difference between two pressure readings, for example across the first check valve of an RPZ valve. RPZ testing records the static, dynamic and differential pressures at the three test points.

Differential pressure valve

Unit 333The underfloor manifold: blending, balancing and safety

A valve that regulates the pressure difference across the manifold so that circuit flow rates stay as set when other circuits open and close.

differential relief valve

Unit 331RPZ valves and single and double check valves

The valve between the two check valves of an RPZ valve, held shut by supply pressure. If supply pressure falls to within about 0.14 bar of the zone pressure, or the zone pressure rises because a check valve leaks, it opens and dumps the zone to drain; a steady discharge from the relief port shows the first check valve is leaking.

Differential temperature controller (DTC)

Unit 332Thermal stores and solar thermal: their pipework layouts

The control that compares the collector temperature with the cylinder temperature and runs the solar circulating pump only while the collector is hotter.

Differential valve

Unit 333Starting up and balancing an underfloor manifold

A valve on the manifold that automatically regulates pressure changes within it, so setting one loop does not disturb the flow rates already set on the others.

Diffuse radiation

Unit 335The solar resource: irradiance, insolation and the seasons

Solar radiation scattered by cloud, dust and water vapour, which appears to come from the whole sky. About half the UK annual total.

Diffuser

Unit 332Solar and twin-coil cylinders: which coil takes which source

A fitting on the cold feed inside a storage vessel that spreads the incoming cold water gently across the base, so that it does not jet upwards and mix the temperature layers.

Digital shower

Unit 332Limiting outlet temperature: bath limits and TMV types

A shower whose temperature and flow are set on an electronic control panel and held by a remote processor operating proportioning valves or a motorised mixing valve.

Dip stick

Unit 334Performance testing a branch pipe for self-siphonage

A thin rule, usually matt black, lowered into a trap to measure the depth of water seal remaining. The wetted length is read off it.

Direct boosting

Unit 331Multi-storey supply: the mains limit and the break cistern

Pumps fitted straight on to the incoming supply pipe so they draw on the main. Allowed only below 0.2 l/s or with the water supplier consenting.

Direct cylinder

Unit 332Direct, indirect and combination cylinders compared

A hot water storage vessel with no heat exchanger, in which the stored water is heated directly by an immersion heater or by circulation through a boiler.

Direct distribution

Unit 335Rainwater harvesting: collection, filtration and storage

Distribution in which harvested water is pumped from the storage tank straight to the points of use, with the control unit introducing mains water when needed.

Direct radiation

Unit 335The solar resource: irradiance, insolation and the seasons

Solar radiation arriving straight from the sun without being scattered.

Direct supervision

Unit 336Craft levels and allocating work: who supervises whom

Supervision in which a competent person is present and watching the work, used where a task is new to the worker, the risk is high, or the worker is inexperienced.

Direct system

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A cold water system where the incoming supply pressure serves the outlets without a storage cistern.

Direct-fired water heater

Unit 332Choosing a hot water system: people, building and appliances

A storage vessel heated by its own burner with factory-fitted controls, rather than by a separate boiler. Mostly used in commercial work.

Discharge pipe (D2)

Unit 333Boilers and cylinders: siting, access and whose rules win

The pipe from the tundish of an unvented cylinder that carries any discharge from the safety valves to a safe outside position. Its route is often what decides where the cylinder can go.

Discharge pipe D1

Unit 332Temperature control, outlets and safety relief pipework

The short metal pipe from a safety device to the tundish. It must be at least the nominal outlet size of the valve it serves.

Discharge pipe D2

Unit 332Temperature control, outlets and safety relief pipework

The pipe from the tundish to a safe outside termination. It falls continuously and is sized up from the valve outlet according to its equivalent resistance length.

Discharge stack

Unit 334Sanitary pipework: the rules and the standard sizes

The vertical pipe that receives branch discharge pipes and carries the flow to the drain. In a primary ventilated system it also ventilates the pipework, which is why it is called a soil and vent pipe.

Discharge unit (DU)

Unit 334Sanitary pipework: the rules and the standard sizes

The design load figure given to each sanitary appliance in BS EN 12056-2 Table 2. Discharge units are added up and converted to a flow rate to size branches and stacks.

Discrepancy

Unit 336Materials changes: substitutions, discrepancies and damaged goods

Something on site that does not match the drawings or tolerances, such as an out-of-position opening or an out-of-tolerance substrate. It must be reported before any further work is done on it.

disinfection

Unit 331Approved contractors: certificates of compliance and other notices

Dosing a new, altered or contaminated water installation with a chemical, normally chlorine, and leaving it in contact for a set time to kill micro-organisms, then flushing it out. BS EN 806-4 sets the method and requires the water supplier to be told beforehand where the chemical could reach the point of delivery.

Displacement heater

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

A small storage water heater in which incoming cold water pushes the stored hot water out of the outlet. Over sink and under sink heaters work this way.

distributing pipe

Unit 331Backflow protection levels: point of use, zone and whole site

A pipe carrying water from a storage cistern to the outlets it serves, under the head given by the cistern rather than mains pressure. Rainwater and greywater systems must have their own dedicated distributing pipework.

Distribution network operator (DNO)

Unit 335The electrical supply and the DNO: settle it at survey

The company that owns and operates the local electricity cables and network. Supply upgrades and reinforcement are agreed with the DNO, not with the energy supplier.

Distribution temperature

Unit 332Design temperatures: storage, flow, return and outlet

The temperature at which hot water travels through the pipework to the outlets. It must bring every outlet to at least 50 degrees C within one minute (55 degrees C in healthcare).

Distributor pipe

Unit 334Terraces, outlet positions and keeping a rainwater system working

A perforated or spreading pipe fitted to a downpipe shoe so that discharge onto a lower roof spreads across a wide enough flow width not to over-top the receiving gutter.

Diversity

Unit 333Checking the existing circuit: rating, condition and damage

The allowance made in a maximum demand calculation for the fact that not all connected equipment operates at full load simultaneously.

Diverter valve

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

The valve inside a combi boiler that redirects primary water to the domestic hot water heat exchanger when a hot tap is opened.

DN

Unit 331Soundness testing: current standards, equipment and procedure

Nominal diameter, the size designation used in BS EN 806-4 to decide which test procedure a combined metal and plastics system uses; DN 63 is the boundary.

DN/OD

Unit 332Soundness testing to BS EN 806-4: procedures A, B and C

Nominal diameter expressed by outside diameter. BS EN 806-4 uses DN/OD 63 as the dividing size for choosing between test procedures on plastics systems.

Do Not Use notice

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The label fixed to every valve and isolator you have closed while work is in progress, saying the system is off and must not be turned on, with the name and telephone number of the person to contact. Only the person who fitted it removes it, and only when the work is finished.

Documented history

Unit 334Manufacturer data, fault charts and documented history

All the written evidence of what a system has already had done to it: commissioning records, maintenance logs, service reports and as-fitted drawings.

Domestic Building Services Compliance Guide

Unit 333Boiler interlock, CHeSS and signing the work off

The guidance document that sets the minimum standards for efficiency, controls, zoning, insulation and commissioning of domestic heating and hot water systems.

Domestic client

Unit 336CDM 2015: duty holders, domestic clients and induction

A person for whom a construction project is carried out that is not in connection with a business. Their client duties normally pass to the contractor or principal contractor.

Domestic Heating Compliance Guide

Unit 336The standards and Approved Documents a specification points to

The supporting guidance for Approved Document L1, setting out how domestic heating and hot water systems should be specified and commissioned to comply.

Dot-and-dab

Unit 336Sequencing with other trades and site readiness

A method of fixing plasterboard to blockwork on dabs of adhesive, leaving a void behind the board that fixings must bridge.

Double check valve

Unit 331Check valves, water hammer and the mini expansion vessel

Two check valves in one body giving backflow protection against a fluid category 3 risk, fitted on the hot and cold to a mixer with a hose.

Double pole (DP) switch

Unit 333Fused connection units: the accessory that feeds the controls

A switch that breaks both the line and the neutral conductor. It contains no fuse, so it is used only on circuits that are already correctly rated and dedicated.

drain down

Unit 331Draining down, standing water and diagnostic readings

Emptying a system, or a section of it, through the drain taps, with the draw-offs above opened so that air can enter to replace the water.

drain tap (drain-off valve)

Unit 331Draining down, standing water and diagnostic readings

A small valve with a hose connection at the low point of a pipe run, cistern, cylinder or vessel, used to empty that section. Pipework downstream of a stopvalve should fall continuously towards one so that nothing is left standing.

Drain-back system

Unit 335Solar thermal: what it delivers and how the circuit works

A system in which the collector automatically empties into a vessel when the pump stops, protecting it from freezing and from stagnation.

Drain-off valve

Unit 331Handover: the file and the demonstration

A valve at a low point for emptying the system; the customer is shown where it is but it needs no operating instructions.

Drainage field

Unit 334Cesspools and septic tanks: how they work and what they need

A system of sub-surface irrigation pipes that lets septic tank effluent percolate into the soil, where biological treatment takes place in the aerated layers.

draining tap

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A small tap fitted at the low points of a system so it can be emptied. It should be a screwdown type to BS 2879, or an approved spherical (ball) type only where it cannot freeze, and must not have a loose washer plate that could lodge in the seat and stop it shutting.

Draw-off pipe

Unit 332Vented hot water storage: cold feed, vent and layout

The pipe taking hot water from the top of the storage vessel to the outlets. It rises from the cylinder rather than falling, because the hottest water is at the top.

draw-off point

Unit 331Available pressure and flow, feed arrangements and loading units

Any outlet from which water is drawn: a tap, shower, WC cistern inlet or appliance valve. Pipe sizing starts at the last draw-off point on a run and works back towards the source.

drawing symbol

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A standard mark used on a drawing to represent a component such as a cistern, valve, pump or vessel, so the drawing can be read by anyone. BS 8558 Table 2 lists the symbols for water services.

Drinking water header

Unit 331Multi-storey supply: the mains limit and the break cistern

A pipe high in a building, filled by direct boosting, holding 5 to 7 litres per dwelling of drinking water for the sinks while the pumps are off.

Drinking Water Inspectorate (DWI)

Unit 332Statutory rules, standards and guidance: which document does what

The body that approves substances and products used in contact with drinking water, including disinfection chemicals, under the water quality regulations.

Drinking Water Inspectorate list of approved products

Unit 331Disinfection: which jobs need it and what disinfectant is used

The list a disinfectant must appear on for use in public water supply (PD 855468 clause 4.10).

Drop tight

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A pressure reducing valve that holds its reduced pressure with no flow, so the downstream pressure cannot creep up.

Drop valve

Unit 334WC flushing: volumes, devices and overflow protection

A flushing device sealed by a mechanical flap or seat that lifts to release the flush. It operates easily and gives a dual flush, but it can leak quietly into the pan.

dry running

Unit 331Booster set controls: accumulator, pressure switch and float switch

A pump running with no water in it. It overheats and destroys its seals within minutes, so a low-level float switch stops the pumps when the cistern empties.

Dry-run switch

Unit 331Multi-storey supply: the mains limit and the break cistern

A low-level float switch in a break cistern that stops the pumps when the water falls too low, so they cannot run dry.

dual flush

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A WC cistern with two flush volumes, a full one and a smaller one for liquids. Schedule 2 paragraph 25 limits the full flush to 6 litres and the smaller flush to no more than two-thirds of it, so the largest dual flush allowed is 6 and 4 litres.

Duplex stainless steel

Unit 332Composite valves, vacuum relief and anti-legionella valves

A high grade stainless steel with a mixed structure giving high strength and good corrosion resistance, used for most modern unvented cylinders.

Duplicate pumps

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

Two or more pumps in parallel on a booster set, sized so peak demand is met with one pump out of action, with the lead pump rotated.

Duration

Unit 336Reading a bar chart: a worked example

The length of time an activity occupies on the programme, read from the length of its bar.

Dust-laden atmosphere

Unit 334Air admittance valves: the conditions they need to work

A space carrying airborne fibres, lint or dust, such as a laundry or workshop. Air admittance valves must not be used in one because the inlet clogs.

duty and standby

Unit 331Sources of fault information: the end user and the manufacturer

The arrangement on a booster set where one pump (the duty) runs to meet demand and the second (the standby) waits to take over on failure or at peak load. The control panel should alternate the duty so that neither pump stands idle and its water stagnates.

Duty holder

Unit 331After handover: signing off and the routine user checks

The person responsible for a non-domestic building's water hygiene under ACOP L8, who keeps the Legionella records.

Duty of care (waste)

Unit 335Refrigerant, waste and the handover pack

The legal duty on anyone producing or handling waste to keep it secure, transfer it only to an authorised person and describe it in writing.

Duty point

Unit 333Pump duty: the index circuit, head and the duty point

The combination of flow rate and head a pump must deliver for a particular system. It is plotted on the pump chart and a curve on or above it is selected.

dye test

Unit 331Identifying non-wholesome pipework and testing for cross connections

A test for cross connection: dye is put into the non-wholesome system before it is connected to the mains back-up, and every wholesome outlet is run and checked to be clear. Required by BS 8525-1 before handover; the water undertaker may ask to witness it.

Dynamic pressure

Unit 331Performance tests: measuring flow and pressure at every outlet

The pressure while water is being drawn, always lower than static because of friction loss; the pressure the outlets actually feel.

Dynamic risk assessment

Unit 336Reviewing and reassessing: keeping it true

The continuous assessment made by a competent worker while the job is under way, checking that what is actually found still matches what was assessed and planned.

DZR brass

Unit 331RPZ valves and single and double check valves

Dezincification-resistant brass, an alloy treated so the zinc is not leached out of it by aggressive water, which would leave the fitting porous and weak. Check valves and other backflow devices are made from it.

Earth fault loop impedance (Zs)

Unit 333Polarity and earth continuity: what each test proves

The total impedance of the path a fault current takes from the point of fault back through the supply. Measured live, and recorded on the certificate as Zs.

Earthing conductor

Unit 333Earthing and bonding a heating control circuit

The conductor joining the main earthing terminal of an installation to the means of earthing, such as the distributor's earthing terminal at the cut-out.

earthing continuity

Unit 331Galvanic corrosion and the seven steps to handover

Keeping the electrical earth path unbroken through metal pipework. When a length of metal pipe is cut out for repair, a temporary bonding lead is fitted across the gap, and BS EN 806-5 clause 10 requires the continuity to be maintained across the repair.

Easing gear

Unit 332Relief valves, strainers and pressures: the annual service

The lever or twist top fitted to a relief valve so that it can be opened by hand for testing. Operating it proves the valve is free and will re-seat.

Eaves gutter

Unit 334Effective roof area: pitch, walls and the two accepted methods

A gutter fixed along the lower edge of a roof slope, the ordinary domestic arrangement. Valley and parapet gutters sit within or behind the roof and are designed to stricter rules.

Ecodesign

Unit 333Handover: the demonstration, the pack and the notices

The part of ErP that places minimum energy efficiency requirements on manufacturers, so that appliances placed on the market meet a defined standard.

Edge insulation

Unit 333Floor insulation and the layers before the screed

The strip of insulation placed round the perimeter of a heated screed before it is poured. BS EN 1264-4 calls it the peripheral insulating strip.

Effective length

Unit 333Pump duty: the index circuit, head and the duty point

The actual length of a pipe run plus an allowance, usually about 33 per cent, for the resistance of fittings and changes of direction. It is used to calculate section resistance.

Effective pipe length

Unit 332Sizing pipes by loading units

The actual measured pipe length plus the equivalent length of all the valves and fittings on that section.

Effective roof area

Unit 334Effective roof area: pitch, walls and the two accepted methods

The area a gutter must be designed to drain: the plan area of the roof corrected for its pitch, with any wall or surface draining onto it added. It is larger than the measured plan area on a pitched roof.

Elastic material

Unit 332Soundness testing to BS EN 806-4: procedures A, B and C

A plastics pipe material such as PVC-U or PVC-C, and multilayer pipe, that expands under pressure but recovers, sitting between metals and visco-elastic plastics in behaviour.

Electrical Installation Certificate (EIC)

Unit 333Certification and notification for heating control work

The BS 7671 model form issued for a new installation, or for an addition or alteration that includes a new circuit or a new consumer unit. Schedules of inspection and test results are issued with it.

Electrical Installation Condition Report (EICR)

Unit 333Certification and notification for heating control work

The report produced after periodic inspection and testing of an existing installation. It reports on condition and is not used to certify new work.

Electricity at Work Regulations

Unit 336The regulations that sit under the Act

Regulations requiring electrical systems to be maintained safe, work on them to be done by competent people with effective isolation, and live work to be avoided.

Electricity at Work Regulations 1989

Unit 333Safe isolation: the seven steps in order

The statutory regulations covering electrical safety at work. They require conductors to be made dead before work where reasonably practicable, and live work only with justification and precautions.

electrochemical series

Unit 331Galvanic corrosion and the seven steps to handover

A list of metals in order of their electrode potential, from noble metals such as copper (+0.15 V) to reactive ones such as zinc (−0.76 V). The further apart two metals sit in the series, the faster the less noble one corrodes when they are joined.

electrolyte

Unit 331Galvanic corrosion and the seven steps to handover

A liquid that conducts electricity because it contains dissolved ions. Water, especially hard or salty water, is an electrolyte, which is what lets galvanic corrosion take place between dissimilar metals.

electrolytic corrosion (galvanic corrosion)

Unit 331Galvanic corrosion and the seven steps to handover

Corrosion that happens when two different metals are in electrical contact with water (an electrolyte) between them. A small current flows; the less noble metal (the anode) is eaten away and the more noble metal (the cathode) is unharmed.

Element area

Unit 333Working a room: a fabric and ventilation heat loss

The area of one part of the fabric, such as a wall, window or floor, used in the U times A times delta T calculation. Wall areas are taken net of openings.

elevation

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A drawing of one face of a building seen from the side, so it shows heights: of a storey, an eaves or a cistern platform. It does not show pipe runs under the floor, the room layout or the drains.

Elevational area

Unit 334Effective roof area: pitch, walls and the two accepted methods

The area of a surface as seen from the side, used for walls and for roofs pitched over 70 degrees. Half of it is taken as the effective catchment.

Elimination

Unit 336Control measures and the hierarchy of control

Removing the hazard from the job altogether, for example by prefabricating off site so that hot work is not needed at all.

Emergency arrangements

Unit 336Presenting a method statement: headings and format

The planned response to a foreseeable emergency on the job, such as rescue from an excavation, first aid, spill response, evacuation and who to call.

Emergency isolation

Unit 331Handover: the file and the demonstration

Shutting off the water supply at the stop valve or isolating valves when a pipe bursts; the customer is shown where the valves are and how to operate them.

Emitter

Unit 335CoP and lift: why flow temperature decides efficiency

The radiator, fan convector or underfloor circuit that gives the heat out into the room. Emitters sized for a boiler are usually too small for heat pump flow temperatures.

Emitter schedule

Unit 333The documents a designer works from, and which one wins

The written list of every room, its design heat loss and the emitter selected to meet it. It is a design document produced by the designer, not a source of data.

Enclosure

Unit 333Visual inspection of the completed controls

The case or box that contains live parts and terminations, providing basic protection against contact and mechanical protection for the connections inside.

end user

Unit 331Sources of fault information: the end user and the manufacturer

The person who uses the water system day to day — the householder, tenant, caretaker or building manager. In fault finding they are the first source of information, because they can describe when the fault started, how it shows itself and what they have already tried.

Energy cut-out

Unit 332Unvented commissioning: pre-charge, fill and relief valves

A non-self-resetting device that disconnects the supply of heat to the storage vessel if the system overheats. It has to be reset by hand, and a trip means something is wrong.

Energy rating

Unit 335Comparing the technologies: carbon, cost and customer fit

The published assessment of a dwelling's energy performance. Installing a micro-renewable system generally improves it, which is one of the benefits a customer values.

Energy supplier

Unit 335The electrical supply and the DNO: settle it at survey

The company that sells electricity to the customer and issues the bill. It owns none of the network equipment.

Enforcement notice

Unit 334Building Regulation Parts and the notice the law requires for drain work

A notice served on a building owner requiring work that does not comply with the Building Regulations to be put right.

Engineering control

Unit 336Control measures and the hierarchy of control

A physical measure designed into the work to protect people, such as a guard, a trench support, local extraction or a working platform.

Engineering Recommendation G98 and G99

Unit 335The electrical supply and the DNO: settle it at survey

Energy Networks Association documents governing the connection of small and larger generation to the distribution network. They apply to generation, not to demand.

EPS

Unit 333Floor insulation and the layers before the screed

Expanded polystyrene insulation. Cheaper than PIR but needs greater thickness for the same U-value, typically about 110 mm in a ground floor.

Equilibrium float valve

Unit 331Large cisterns: warning pipes, overflows and inlet valves

A float valve with a hole through its piston so inlet pressure acts on both sides; the float only lifts the arm, which suits high-pressure inlets and reduces hammer.

Equivalent hydraulic resistance

Unit 332Discharge pipework: the tundish, D1 and D2

The resistance of bends and fittings expressed as an extra length of straight pipe, added to the actual run when sizing a discharge pipe.

equivalent length

Unit 331Accumulators on a weak main and the calculation sheet

The length of straight pipe that would cause the same head loss as a fitting such as a bend, tee or valve. Added to the measured pipe length to give the effective length used in the head loss calculation.

Equivalent pipe length

Unit 332Sizing pipes by loading units

The length of straight pipe that would cause the same pressure loss as a valve or fitting. Adding it to the measured length gives the effective length used for sizing.

ErP energy label

Unit 335SCOP, SPF and system efficiency: the honest figures

The energy label supplied with a product so consumers can compare efficiency consistently. It shows an efficiency class alongside data such as rated output and sound power level.

erroneous measurement

Unit 331The Water Regulations: origin, enforcement and the five harms

One of the five harms: anything that stops the water meter recording the amount of water that actually passed through it, such as a pipe connected so that it bypasses the meter.

Escalation

Unit 333Manufacturer instructions, fault codes and flow charts

Passing a fault to the manufacturer or a specialist because it is beyond your competence or your authorisation to deal with.

Essex flange

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A flange fitted in the side of a hot water cylinder to draw hot water for a shower pump below the air at the top, so the pump does not draw air.

estimate

Unit 331Design information: manufacturer data, customer feedback and scale plans

An approximate price for a piece of work that can change as the job proceeds, unlike a quotation, which is fixed. On larger jobs it is produced from the bill of quantities.

Estimator

Unit 336Cost and quantities: estimator and quantity surveyor

The person who prices work before it is carried out, breaking the bill of quantities into labour, materials and plant, applying rates and adding overheads and profit.

Ethylene glycol

Unit 336Substances on site: data sheets, glycol and spills

A glycol used as an antifreeze and heat transfer fluid. It is considerably more toxic if swallowed than propylene glycol.

Evacuated tube collector

Unit 335Collectors: flat plate, evacuated tube and unglazed

A collector made from double-walled glass tubes with the air evacuated, which almost eliminates conduction and convection losses.

Evaporation

Unit 334The six causes of trap seal loss, and how to tell them apart

Loss of a trap seal by the water drying away when the appliance is not used. BS EN 12056-2 ND.2.5 warns that infrequent use can give total loss of seal.

Evaporator

Unit 335Heat pumps: how the refrigeration cycle moves heat

The heat exchanger where the refrigerant boils and absorbs low-grade heat from the air, ground or water.

Evaporator coil

Unit 333Servicing a heat pump: coil, defrost and the water side

The finned coil in an air source unit through which outside air passes and from which the refrigerant absorbs heat.

Exclusions

Unit 336Variation orders: pricing extra time and extra cost

The part of a written quotation that lists what the price does not cover. Anything not named there is normally the contractor's cost if it turns out to be needed.

Exhaust air heat pump

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

A heat pump that recovers heat from the warm, stale ventilation air being extracted from a dwelling. Its output is capped by the ventilation rate, so it suits small, airtight properties.

Existing control measures

Unit 336Writing it down: forms, formats and who signs

The controls already in place before the assessment is made, recorded on the form so that the further action needed can be judged against them.

Expansion (pressure) relief valve

Unit 332Temperature control, outlets and safety relief pipework

A valve on the cold supply close to the vessel that discharges water if the pressure rises above its setting, for example when the expansion vessel has failed.

Expansion factor

Unit 333Expansion: sizing the vessel and the feed and expansion cistern

The proportion by which the water in a system increases in volume between its fill temperature and its maximum operating temperature, written as e in the vessel sizing formula.

Expansion relief valve

Unit 332Expansion on an unvented system: vessel, valve and balanced cold

A pressure activated valve that releases expansion water if the expansion vessel or bubble fails, or if the supply pressure becomes excessive. It is listed with the functional controls, but its job is safety; it is not one of the two safety devices Approved Document G requires.

Expansion valve

Unit 332Reading the discharge: which valve, when and how hot

A pressure-operated relief valve on the cold inlet of an unvented cylinder. It opens when system pressure rises above its setting, which happens if the expansion vessel or the pressure reducing valve fails. Also called the expansion relief valve or pressure relief valve.

Expansion vessel (unvented hot water)

Unit 331Booster sets: the pressure vessel and the control switches

The vessel on an unvented hot water system that takes up the expansion of heated water, sized on the volume heated and the operating pressure at not less than 4 per cent.

Exposed location allowance

Unit 333Working a room: a fabric and ventilation heat loss

An addition of about ten per cent to a calculated heat loss where the building is on an exposed site, to cover severe weather.

Exposure

Unit 333Design temperatures: inside, outside and the difference

How sheltered or open a building's location is. Exposed coastal, high altitude and rural sites use a lower external design temperature and may carry an extra percentage allowance.

External design temperature

Unit 333Design temperatures: inside, outside and the difference

The realistic low outside temperature the system is designed against, taken as a regional figure from published data rather than the coldest ever recorded.

External influences

Unit 333Damaged cable: recognising it and putting it right

The conditions a wiring system has to withstand where it is installed, such as heat, water, impact, vibration and sunlight. The cable and its protection are chosen to suit them.

Externally sited break cistern

Unit 331Private water supplies: sources and responsibilities

A covered storage cistern outside the house on a private supply, from which a booster set pumps into the building. Insulated, lockable and screened.

Extraneous-conductive-part

Unit 333Earthing and bonding a heating control circuit

A conductive part that is not part of the electrical installation but is liable to introduce a potential, such as incoming metal water or gas pipework. It is bonded, not earthed as a protective conductor.

F gas Regulations

Unit 335Refrigerant, waste and the handover pack

The law controlling fluorinated greenhouse gases used as refrigerants. Deliberate release is prohibited and recovery must be recorded.

F-Gas qualification

Unit 333Setting the controls: flow temperature, hot water and defrost

The qualification required to work on sealed refrigerant circuits containing fluorinated greenhouse gases. Without it, an operative must not break into the circuit or adjust the charge.

F-Gas Regulations

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

The regulations controlling work on fluorinated refrigerant circuits. Anyone brazing, pressure testing, evacuating or charging a refrigerant circuit on site must hold a relevant handling qualification.

Fabric first

Unit 333The building: layout, size and the order of the work

The principle that reducing a building's heat loss by insulation and sealing is cheaper and more permanent than buying extra heat generator capacity to replace the lost heat.

Fabric heat loss

Unit 333Heat loss: the fabric route and the ventilation route

Heat conducted out through the building structure. It is calculated element by element as U multiplied by area multiplied by the temperature difference.

Fall

Unit 334Walking the finished system: the visual inspection on site

The gradient given to a near-horizontal discharge pipe, so it drains completely at a self-cleansing velocity. Usually expressed as a ratio or as millimetres of fall per metre.

Fault code

Unit 333Manufacturer instructions, fault codes and flow charts

A number or letter sequence shown on a display to indicate which protection or check has operated. Codes are specific to the manufacturer and model.

Fault diagnosis

Unit 334Taking the fault call: what the end user can tell you

The process of working from reported symptoms and observed evidence to the actual cause of a fault, before any repair is attempted.

Fault diagnosis flow chart

Unit 332Manufacturer instructions, flow charts and service history

A step-by-step decision tree supplied by a manufacturer. Each step asks a question that can be answered yes or no and directs you to the next test or to the cause.

Fault-finding chart

Unit 334Running the macerator: cycle, leaks, faults and handover

The flow chart in a manufacturer's instructions that leads from a symptom to a likely cause and a check to make.

Fault-finding flow chart

Unit 334Manufacturer data, fault charts and documented history

A manufacturer's diagnostic chart that works through a fault by symptom, each yes or no answer leading to the next check. It is the first reference for a pumped or powered sanitary component.

Feed and expansion cistern

Unit 332Direct, indirect and combination cylinders compared

The small cistern that fills a vented primary circuit and accepts its expansion. It is separate from the cold water storage cistern in a double feed system.

Ferrule

Unit 333Terminations and joints: making the connection last

A small metal tube crimped onto the end of a fine-stranded conductor so the strands cannot spread or separate in a screw terminal.

Filling degree

Unit 334Sizing the gutter, the outlet and the downpipe

The proportion of a vertical rainwater pipe's cross-section occupied by water. BS EN 12056-3 uses 0.33 unless national practice sets another value between 0.20 and 0.33.

filling loop

Unit 331Filling loops and outside taps: protecting heating and garden connections

A temporary flexible connection between the supply pipe and a sealed heating system used to fill or top it up. It carries a double check valve on the supply side, never the heating side, and is disconnected after use. It is accepted on a house system; the withdrawn BS 6700 also allowed it on a non-domestic system under 40 kW.

Fin comb

Unit 333Servicing a heat pump: coil, defrost and the water side

A small tool used to straighten bent fins on a coil so that airflow through it is restored.

Final account

Unit 336Cost and quantities: estimator and quantity surveyor

The statement prepared at the end of a contract, showing the total value of the work carried out and the final sum due.

Final balancing

Unit 333The underfloor heat-up, final balancing and set-back

The second balance of the loops, carried out once the building is furnished and has been running at design temperature for at least a week, because floor coverings change each loop's output.

Final circuit

Unit 333Fused connection units: the accessory that feeds the controls

A circuit connected directly to current-using equipment or to socket outlets, taken from a distribution board or consumer unit.

Final inspection

Unit 334The visual inspection: what a completed system must show

The check made on completion of a discharge system, before testing, to confirm the standard has been followed and that nothing has been left in or projecting into the pipes.

Final test

Unit 331Soundness testing: current standards, equipment and procedure

The soundness test on the whole installation at completion, required by the Regulations and recorded on the commissioning record.

Fine wire conductor

Unit 333Terminations and joints: making the connection last

A conductor made of many very thin strands, as used in flexible cable. It needs a suitable terminal or a treated end so that the strands cannot spread.

Finger barrier

Unit 333Proving dead: the indicator, the proving unit and three readings

The raised guard on a test probe that stops a hand sliding forward onto the live conductor being tested.

Fire compartment

Unit 336The design team: architect, engineers and surveyor

A part of a building enclosed by fire-resisting walls and floors, designed to contain a fire. Services passing through a compartment line must be properly fire sealed.

Fire stopping

Unit 334Fire stopping, access and notification

Sealing an opening or gap in a fire separating wall or floor so that fire and smoke cannot pass through it for the required period.

First fix

Unit 333First fix: the manifold, the sequence and other trades

The stage of work before the building is closed in and finished, when wiring, pipework and fixings go in and positions are agreed.

Fixed cost contract

Unit 336Contract types: fixed cost, variable cost and cost plus

A contract where the price is agreed before the work starts and does not vary unless the work itself is varied by agreement.

Fixed equipment

Unit 333Supplying and isolating the controls on site

Equipment secured in place and connected permanently to the fixed wiring, such as a boiler, a pump or a controller. It is not supplied through a plug and socket.

Flanged union

Unit 333The circulating pump: position, isolating valves and unions

The bolted or screwed union connection each side of a circulating pump. The joint is sealed with a flat rubber washer.

Flat plate collector

Unit 335Collectors: flat plate, evacuated tube and unglazed

A glazed, insulated collector with an essentially flat absorber plate and no concentration of the radiation.

Flexible cable (flex)

Unit 333Choosing and routing cable for heating controls

Cable whose conductors are made of many fine strands so that it can be bent repeatedly without fracturing. Used for connections to pumps, valves and appliances.

Float

Unit 336Reading a bar chart: a worked example

The spare time available to an activity: the amount by which it can be delayed without affecting the completion date.

Float switch

Unit 331Multi-storey supply: the mains limit and the break cistern

A switch that rises and falls with the water level and makes or breaks an electrical circuit, used to start and stop pumps or signal a valve.

Float-operated valve (BS 1212)

Unit 331Large cisterns: warning pipes, overflows and inlet valves

The ordinary float valve in which a float and lever close a washer on a seat. Restrictive and slow on a large cistern.

Floating extraction point

Unit 335Rainwater harvesting: collection, filtration and storage

A draw-off that floats about 100 to 150 mm below the water surface, taking water from the cleanest part of the tank.

Floating floor

Unit 333The three underfloor floor constructions compared

An underfloor construction where grooved structural insulation panels are laid loose on the sub-floor, with a transfer plate and pipe in the groove and the finish over the top.

Flood level

Unit 334Air admittance valves, stack terminations and housing sites

The level to which foul water would rise in a blocked system, taken at the highest appliance served. An air admittance valve is always fitted above it.

Floor covering resistance

Unit 333Underfloor heating faults: the manifold, the loops and a hot floor

The thermal resistance added by carpet, timber, tile or vinyl over a heated floor. The design assumes a particular covering, and changing it changes the output.

Floor loading

Unit 332Siting the cylinder: weight, clearance and the discharge route

The weight a floor has to carry at a given point. For a cylinder it is the vessel plus its full contents, reckoned at roughly one kilogram per litre.

floor plan

Unit 331Design information: manufacturer data, customer feedback and scale plans

A plan of one floor of a building, usually at 1:100 or 1:50, showing the room layout, wall thicknesses, appliance positions and horizontal pipe runs. With the bill of quantities it is used to work out the cost of a job before it starts.

Flow limiting valve

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A valve with an interchangeable cartridge that passes a set flow, between about 0.07 and 0.43 l/s, regardless of the pressure upstream.

Flow meter

Unit 333The underfloor manifold: blending, balancing and safety

A sight gauge on the flow bar of an underfloor manifold that shows the flow rate through one circuit, usually in litres per minute.

flow pressure

Unit 331Cistern sizing, float valve refill and pipe design limits

The pressure at an outlet while water is flowing, always lower than the static pressure because of friction in the pipe. BS EN 806-3 requires at least 100 kPa (1 bar) at a draw-off point; also called dynamic or running pressure.

Flow rate

Unit 333Flow rate and pipe size: from kilowatts to millimetres

The mass or volume of water passing a point each second, in kilograms or litres per second. It is found from the heat duty and the design temperature difference.

flow restrictor

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A small fitting that limits the rate at which water can pass through a tap or inlet. It saves water only on fittings that consume in proportion to flow, such as taps and showers; a WC uses a fixed volume per flush, so restricting its inlet saves nothing.

Flow sensor

Unit 331Borehole pumps: packaged sets, controls and the accumulator

A sensor in a packaged set control box that stops the pump if no water is passing, protecting a submersible in a dry borehole.

Flow switch

Unit 331Borehole pumps: packaged sets, controls and the accumulator

A switch operated by water moving through it. Found on some small direct-boosting pumps and on shower pumps, but not the normal control on a boosted private supply.

Flow temperature

Unit 335CoP and lift: why flow temperature decides efficiency

The temperature of the water leaving the heat pump to the emitters. Heat pumps are designed for low flow temperatures, typically around 35 to 45 °C.

flow velocity

Unit 331Cistern sizing, float valve refill and pipe design limits

The speed of the water along the pipe in metres per second. BS EN 806-3 bases its tables on 2.0 m/s in distribution and rising pipes and 4.0 m/s in a connection to a single fitting (the withdrawn BS 6700 allowed 3 m/s); it is kept low mainly to limit noise, and also erosion of the pipe wall.

Flow-measuring valve

Unit 333Balancing radiators to the design temperature difference

A regulating valve with a built-in flow indicator, so the circuit can be set directly to a flow rate in litres per minute instead of being inferred from temperatures.

fluid category

Unit 331Fluid categories: grading water and regrading a building

Schedule 1 of the Water Fittings Regulations grades water by the harm it could do if it flowed back into the supply: category 1 is wholesome mains water, 2 has only its aesthetic quality changed (hot or softened water), 3 is a slight health hazard (low-toxicity substances such as glycol or disinfectant), 4 a significant hazard (toxic substances such as pesticides) and 5 a serious hazard (pathogens, faecal matter, radioactive or very toxic substances). Backflow protection must match the highest category downstream.

Fluid category 1

Unit 331Direct, indirect and boosted systems: extra checks and first fill

Wholesome water supplied by the water undertaker, the only water used to fill a drinking water installation for testing.

Fluid category 1 water

Unit 332Filling and venting at normal operating pressure

Wholesome water supplied by a water undertaker, complying with the drinking water regulations. It is the only water used for filling, testing and flushing a potable system.

fluid category 2

Unit 331Backflow risk: the duty and the five fluid categories

Category 1 water whose aesthetic quality has been impaired by a change in temperature, or by substances or organisms altering its taste, smell or appearance, but which is not a health risk. Hot water, cold water that has warmed up, and hot and cold meeting in a mixer are category 2. Schedule 1 sets no temperature figure: any change is enough.

Fluid category 3

Unit 331Check valves, water hammer and the mini expansion vessel

A backflow risk from water that is a slight health hazard, such as bath water, protected against by a double check valve.

fluid category 4

Unit 331Backflow risk: the duty and the five fluid categories

A significant health hazard from toxic substances: chemicals, carcinogens, pesticides and environmental organisms of health significance. Heating primaries outside a house, sprinklers with antifreeze, porous garden hoses, commercial dishwashers and car wash plant are category 4; the highest category any mechanical device can protect against.

fluid category 5

Unit 331Backflow risk: the duty and the five fluid categories

A serious health hazard from pathogens, radioactive or very toxic substances, including faecal and other human or animal waste. WC pans, urinals, bidets, kitchen sinks in any premises, hospital basins, animal troughs, non-domestic hose union taps, rainwater and greywater are category 5, and only an air gap protects against it.

flushing

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

Passing clean water through a new or altered installation at a good velocity to clear out flux, swarf, debris and stagnant water before it is used. Schedule 2 paragraph 13 requires it before first use and BS EN 806-4 sets the method; it comes before disinfection, and a booster installation is flushed again after maintenance.

Flushing cistern

Unit 334WC flushing: volumes, devices and overflow protection

The vessel that stores and delivers the flush volume for a WC or urinal. Every one except a pressure flushing cistern carries an indelible internal line showing the flush volume.

Flushing velocity

Unit 331Flushing: the legal order and the BS EN 806-4 method

The speed of the water during a flush: at least 2 m/s for a plain water flush, or 0.5 m/s for a pulsed water/air flush.

flux

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

The paste applied to copper pipe before soldering to clean the metal and let the solder flow. Most fluxes are acidic and corrosive, so excess flux left inside new pipework is the commonest cause of internal corrosion; use the least that will make the joint and flush it out before use.

Food waste disposal unit

Unit 334Sink waste disposal units: jams, overloads and blockages

A unit fitted under a sink that grinds food waste into a paste and flushes it into the drainage system through a 40 mm outlet.

Foot of the stack

Unit 334Compression at the foot of the stack, and putting faults right

The bottom of a discharge stack, where it turns into the drain. Positive pressure is greatest here, so low branches are kept clear of it.

Formal inspection

Unit 336Work at height: ladders, harnesses and the definition

A recorded inspection of access equipment carried out at set intervals, for ladders every three months, in addition to pre-use checks.

Foul air

Unit 334Smells and slow running: what each complaint points to

The contaminated air inside a drainage system. A trap seal, an intact pipe and a correctly seating valve are what keep it out of the building.

Foul water

Unit 334Sanitary pipework: the rules and the standard sizes

Waste water from a sanitary convenience or bidet, from an appliance used for washing foul receptacles, or water used for food preparation, cooking or washing.

Four-pipe buffer

Unit 333System volume, buffers and short cycling

A buffer with separate generator and emitter connections, giving hydraulic separation between the two circuits at the cost of mixing, which lowers the temperature reaching the emitters.

Four-port buffer

Unit 333Multiple boilers, low loss headers and hydraulic separation

A buffer vessel with separate connections for the heat source and the system, adding both volume and separation, at the cost of mixing that lowers the system side temperature.

Free chlorine

Unit 331Chlorine disinfection: the figures, the people and the samples

The chlorine in the dosed water that is still available to disinfect, measured in mg/l; dosed at 50 mg/l and read as a residual at the end of the contact time.

Free residual chlorine

Unit 332Disinfection: when it is needed and the figures

The chlorine still available in the water at the end of the contact period, measured in mg/l. It shows how much chlorine the system consumed and whether the disinfection worked.

Freeboard

Unit 334The water test and the gutter test: where each one applies

The depth of gutter left above the design water level. A gutter test fills to the overflow level or to the lower level of the freeboard.

Freeze burn

Unit 336Equipment and energy: wheels, isolation and refrigerant

A cold burn caused when a liquid such as refrigerant boils on contact with skin and rapidly draws heat out of the tissue.

Frequency factor (K)

Unit 334Sanitary pipework: the rules and the standard sizes

A multiplier in BS EN 12056-2 that allows for how often the appliances are used, from 0.5 for a dwelling up to 1.2 for special use.

Friction loss

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The pressure lost as water flows through pipework, fittings and valves, which the pump must overcome on top of the static lift.

Frost heave

Unit 335Ground source heat pumps: the four collector types

The lifting of ground and pipework caused by soil freezing and expanding. In a ground array it is a symptom of an undersized collector.

Frost protection

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

Measures such as insulation or draining that stop a system standing full over winter from freezing.

Frost thermostat

Unit 333Programmers, thermostats and the wiring centre

A protection control that fires the boiler when air temperature approaches freezing, always used with a pipe thermostat, and overriding all other controls.

Full bore flow

Unit 334The six causes of trap seal loss, and how to tell them apart

Flow that fills the whole cross-section of a pipe. In a branch discharge pipe it is what makes siphonage possible, because air cannot get past the water.

Full house system

Unit 333Underfloor with radiators: mixed temperature systems and zones

An underfloor installation serving the whole dwelling from one or more manifolds, with room-by-room control and a heat source that can run at low temperature throughout.

Full load equivalent run hours (FLEQ)

Unit 335Sizing a ground collector: extraction rates and area

The number of hours a system would run at full output to deliver its annual heat. It is the run-hours assumption behind a ground collector design.

full plans

Unit 331Building Regulations Part G: notices and competent person self-certification

One of the two ways of notifying building control: drawings and a specification are deposited and approved before work starts, then the work is inspected. It suits larger or more complex jobs; a building notice is the alternative.

Full plans application

Unit 334Notifying building control: notices, full plans and competent persons

An application depositing detailed drawings and specification with the local authority so that the design can be checked before work begins.

Fully filled system

Unit 335Stagnation: the limitation designed into every solar system

A solar primary circuit that stays full of fluid at all times, in contrast to a drain-back system. Every component in it must be rated for the collector's stagnation temperature.

Fully pumped system

Unit 333S-plan and S-plan plus: two-port valves and separate zones

A system in which both the heating circuit and the hot water primary circulate by pump, so both can be controlled electrically. Required by the current standards.

Functional control

Unit 332Three levels of safety on an unvented cylinder

A control that makes the system work correctly day to day and protects the water supply, such as the strainer, reducing valve, check valve, expansion device and control thermostat. The expansion relief valve is listed with them too, although its job is safety.

Functional test

Unit 332Flow rate, pressure, balancing and the controls

A test that proves a piece of equipment is properly mounted, adjusted and installed and operates correctly, by running it through its intended operation.

Functional testing

Unit 331Balancing, mechanical controls and functional testing

Running the system through its cycle to prove that the switchgear and controls operate correctly.

Fused connection unit (FCU)

Unit 333Fused connection units: the accessory that feeds the controls

A fixed accessory by which appliances are connected to the fixed wiring, containing a replaceable cartridge fuse link. Made to BS 1363-4 and available switched or unswitched, with or without a flex outlet.

Fused spur

Unit 333Fused connection units: the accessory that feeds the controls

A fused connection unit supplied as a spur from an existing circuit rather than by its own circuit from the consumer unit. The usual way of feeding heating controls.

G half

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

A parallel pipe thread size, the half inch thread used on the tails of most basin and sink taps; G three-quarters is the three-quarter inch thread of a bath tap. The AUK2 tap gap is set by this thread size: 20 mm up to G half, 25 mm up to G three-quarters, 70 mm above G three-quarters.

galvanic corrosion

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

Corrosion that occurs when two dissimilar metals are joined in water, which acts as an electrolyte: the less noble metal corrodes away. Galvanised steel downstream of copper is the worst case because dissolved copper plates on to the zinc and sets up cells throughout the steel; an insulating connector breaks the electrical path but does nothing about copper already in solution.

Gantt chart

Unit 336Work programmes: what they are and what they show

A chart with activities listed down the side and time across the top, each activity shown as a bar spanning the period it occupies. Another name for a work programme.

Gas Safety (Installation and Use) Regulations 1998

Unit 333Boilers and cylinders: siting, access and whose rules win

The statutory regulations covering work on gas appliances and pipework in Great Britain. Positioning a boiler to the manufacturer's instructions is part of complying with them.

Gate valve

Unit 331Borehole pumps: packaged sets, controls and the accumulator

A full-bore isolating valve with a sliding gate, fitted first on the pump delivery pipe so the system can be shut off for work.

General Permitted Development Order (GPDO)

Unit 335Permitted development: what it means, and solar on a roof

The town and country planning order that grants permitted development rights and sets their conditions. It is amended from time to time.

Generic risk assessment

Unit 336The five steps of a risk assessment

A standard assessment covering a type of work a company does regularly, which must still be checked and adapted for the particular job and place.

Glycol

Unit 332Thermal stores and solar thermal: their pipework layouts

A colourless, odourless antifreeze mixed with the water in an indirect solar primary circuit to stop it freezing. The proportion is set by the manufacturer.

Gradient

Unit 334Primary ventilated stacks: the branch limits that decide the layout

The fall of a pipe, given in millimetres per metre of run. 18 mm per metre is about 1 in 55.

Gravity circulation

Unit 333Poor circulation: air locks, blockages and pump faults

Water circulating without a pump because hot water rises and cooler water falls. It can move heat upwards only.

Gravity cleaning

Unit 333Cold flushing, hot flushing and the power flush

Circulating the cleaner with the help of the system pump, then repeatedly draining and refilling the whole system with fresh water until the water runs clear.

Gravity supply

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A private supply where the source is higher than the house and water flows in from a catchment tank without a pump.

Grease trap

Unit 334Sink waste disposal units: jams, overloads and blockages

A chamber that separates grease from kitchen wastewater. Appliances discharging heavy concentrations of solid matter should not discharge into one.

Green-and-yellow sleeving

Unit 333Terminations and joints: making the connection last

Coloured sleeving fitted over a bare circuit protective conductor at a termination so that the core is identifiable, as required by Regulation 514.3.2.

greywater

Unit 331Approved contractors: certificates of compliance and other notices

Waste water from baths, showers and basins that is collected, treated and reused for WC flushing or irrigation. Like rainwater it is non-wholesome, so BS 8525-2 requires identified, separate pipework and notification to the water supplier before work starts where there is a mains supply.

Grid-supplied electricity

Unit 335Comparing the technologies: carbon, cost and customer fit

Electricity drawn from the public network, as opposed to generated on site. On today's factors (SAP 10.2) it carries less carbon per kWh than natural gas, though it is still the dearer fuel per kWh.

Grommet

Unit 333Damaged cable: recognising it and putting it right

A rubber or plastic bush fitted in a hole or knockout so a cable passing through it is not cut or abraded by the edge.

Ground array

Unit 335Sizing a ground collector: extraction rates and area

The complete buried collector serving a ground source heat pump, made up of one or more circuits of pipe.

Ground collector

Unit 333Fuel, efficiency and environmental impact of the choice

The buried pipework that takes heat from the ground for a ground source heat pump. Forms include the coiled slinky in a trench, straight horizontal loops and vertical boreholes.

Ground heat exchanger

Unit 335Ground source heat pumps: stable source, higher cost

The buried or submerged pipework through which brine collects heat from the ground or from water. Also called the ground loop or ground collector.

Ground source heat pump (GSHP)

Unit 335Ground source heat pumps: the four collector types

A heat pump that collects low-grade heat from the ground through a buried collector and raises it to a useful temperature for heating and hot water.

Group mixing

Unit 332Limiting outlet temperature: bath limits and TMV types

An arrangement where several similar appliances are served from one thermostatic mixing valve. It is not recommended where the occupants are high risk.

GS38

Unit 333Dead tests and live tests: the order and the instruments

HSE guidance on electrical test equipment for use by electricians. It covers probes, leads and the safe proving of test instruments.

GS38 voltage indicator

Unit 332Thermostats, cut-outs, programmers and motorised valves

A test instrument for proving the presence or absence of voltage, built to the HSE guidance note GS38 so that exposed metal at the probes is limited.

Guideline value

Unit 335Greywater re-use: a steadier supply, a heavier burden

A recommended water quality figure given in BS 8525-1 for treated greywater. There are no statutory water quality limits for non-potable re-use, so these guideline values are what a well-run system is judged against.

Gully

Unit 334Traps, seal depths and how a trap loses its seal

A trapped fitting at ground or basement level that receives waste water discharges before they enter the drain.

gunmetal

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A bronze alloy of copper, tin and zinc that resists dezincification and corrosion, so it is the traditional material for valves and fittings that will be buried, concealed or used on aggressive water. Schedule 2 paragraph 7 requires concealed fittings and mechanical backflow devices to be gunmetal or dezincification-resistant.

Gutter outlet

Unit 334Sizing the gutter, the outlet and the downpipe

The opening in the gutter that connects it to the rainwater pipe. It is often the part that limits the capacity of the whole system.

Habitable room

Unit 335Heat pumps and permitted development: volume, boundary and noise

A room used for sleeping or living. MCS 020 a) excludes bath and toilet facilities, service rooms, corridors, laundry rooms, hallways and utility rooms, and heat pump noise is assessed 1 m from any door or window of one in a neighbouring property.

Half round gutter

Unit 334Sizing the gutter, the outlet and the downpipe

The semi-circular gutter profile used on most domestic properties. The Approved Document H sizing table is based on nominal half round eaves gutters laid level.

Hand pump

Unit 334Setting up the air test: plugs, manometer and charged traps

The small bellows or bulb pump used to raise the air pressure inside sanitary pipework to the test figure.

handover

Unit 331Identifying non-wholesome pipework and testing for cross connections

The point at which the completed installation is passed to the client, with the tests done, the certificates and instructions given, and the system demonstrated. Tests such as the dye test must be completed and recorded before it.

Handover pack

Unit 333Functional testing, commissioning and handover

The documents left with the customer at completion: certificates and schedules, the commissioning record, manufacturer's instructions and a system schematic.

Harm

Unit 336Hazard and risk: telling the two apart

The injury or ill health that a hazard could cause, such as a fall, a burn, a laceration or a lung disease.

Hazard

Unit 336Hazard and risk: telling the two apart

Anything that has the potential to cause harm, such as a chemical, electricity, a naked flame, a wet floor or an unsupported excavation.

Head height

Unit 335Orientation, tilt and shading: judging a site for solar

The vertical distance a body of water falls in a hydro scheme. With flow rate it is one of the two criteria that decide whether micro hydro is viable.

head loss

Unit 331Accumulators on a weak main and the calculation sheet

The pressure lost to friction as water flows along a pipe, expressed as metres of head and usually read from a pipe chart as head loss per metre of pipe for a given flow and diameter. The total for a section is head loss per metre multiplied by the effective length.

Health and Safety at Work etc. Act 1974 (HASWA)

Unit 336The Health and Safety at Work Act: duties on everyone

The principal piece of health and safety legislation in the UK. It sets out the general duties of employers, employees and the self-employed, and the more detailed regulations sit under it.

Health and Safety Executive (HSE)

Unit 336The Health and Safety at Work Act: duties on everyone

The government body responsible for the regulation and enforcement of workplace health, safety and welfare law in Great Britain.

Health and safety file

Unit 331The commissioning record and the defects that go on it

The file handed over on a construction project holding installers' details, method statements and permits; on a large contract the handover documents form part of it.

Health and safety manager

Unit 336Running the job: managers, clerk of works and supervisors

The person accountable to senior management for health and safety on site, including safety inspections, records, accident investigations, training and inductions.

Health and safety policy

Unit 336The Health and Safety at Work Act: duties on everyone

The employer's written statement of its health and safety intentions and the arrangements for carrying them out. It must be written down where five or more people are employed.

Heat emission plate

Unit 333The three underfloor floor constructions compared

A profiled aluminium plate that holds the underfloor pipe and conducts the heat sideways across the floor. Also called a heat transfer or spreader plate.

Heat emitter

Unit 333One-pipe, two-pipe and reverse return layouts

Any component that gives up the heat carried by the system water to the room, such as a radiator, a convector, a skirting heater or a heated floor.

Heat gain

Unit 333Heat gains, pipework losses and what the design ignores

Heat entering a space from a source other than the heating system, such as sunlight, people, electrical equipment or a warmer adjoining room.

Heat generator

Unit 333Boilers and cylinders: siting, access and whose rules win

The standards term for the appliance that produces the heat, normally the boiler. BS EN 12828 uses it so the same rules cover boilers, heat pumps and heat exchangers.

Heat input (P)

Unit 332Sizing the cylinder: 45 litres per occupant and the storage formula

The rate at which heat is delivered into the stored water, in kilowatts. For an immersion or a direct-fired heater it is the appliance output; for an indirect cylinder it is an average value across the reheat.

Heat leak radiator

Unit 333Emitter load: correcting catalogue output to real conditions

A radiator left permanently open on a solid fuel system so that heat can escape when the pump stops or the controls close. It is connected top, bottom, opposite ends so it circulates by gravity.

Heat loss coefficient

Unit 335Collector performance: aperture area and the efficiency curve

A figure from the collector test data describing how quickly efficiency falls as the absorber becomes hotter than the surrounding air. First and second order coefficients are quoted.

Heat pipe

Unit 335Collectors: flat plate, evacuated tube and unglazed

A sealed pipe inside an evacuated tube containing a volatile liquid that vaporises, rises, condenses at a heat exchanger in the header, and drains back.

Heat pump cylinder

Unit 332Heat pump cylinders: coil area, store temperature and reheat

A hot water storage vessel designed for a low temperature heat source, with a much larger coil, typically about 3 square metres, so that it can absorb the available power across a small temperature difference.

Heat recovery

Unit 332Scale, blockages, airlocks and leaks

The time taken for the heat source to bring a full cylinder of cold water up to its set temperature after the hot water has been drawn off. Also called the recovery time.

Heat spreader plate

Unit 333Underfloor pipework: patterns, insulation, screed and testing

A shaped aluminium plate that holds the pipe and spreads its heat across the underside of a timber floor.

Heat transfer fluid

Unit 335Stagnation: the limitation designed into every solar system

The fluid circulated between collector and store, usually water with glycol antifreeze and a corrosion inhibitor package. Its condition and pH are service checks, not fit-and-forget items.

Heat-resisting flex

Unit 333Choosing and routing cable for heating controls

Flexible cable with insulation rated for higher temperatures than ordinary PVC, used where the cable must run close to a heat source such as a boiler or primary pipework.

Heating circuit

Unit 333Zoning: how many zones, and what each one controls

A pipework run serving a number of radiators that is controlled by its own zone valve. Two thermostats on one valve do not make two circuits.

heating primary circuit

Unit 331Filling loops and outside taps: protecting heating and garden connections

The pipework carrying water between a boiler and the radiators or a cylinder coil; the primaries. In a house it is fluid category 3, and outside a house category 4, which decides the backflow device on any connection to the supply.

Heating-up capacity

Unit 333Total heat load, hot water load and the boiler size

The extra output allowed so a building can be brought back to temperature after the heating has been off, rather than only held at temperature once warm.

Hierarchy of control

Unit 336Control measures and the hierarchy of control

The order in which controls are chosen: eliminate, substitute, engineering controls, administrative controls, and personal protective equipment last.

High breaking capacity (hbc) fuse

Unit 333Proving dead: the indicator, the proving unit and three readings

A fuse able to interrupt a very large fault current safely. Fitted in test leads so a wrongly set instrument cannot release the full fault energy.

High limit thermostat

Unit 332Temperature control, outlets and safety relief pipework

A second, independent temperature control, also called an energy cut-out, that removes the energy supply if the working thermostat fails. It is either manually reset or non-resettable.

High pressure switch

Unit 331Booster sets: the pressure vessel and the control switches

The pressure switch set at the cut-out pressure that stops the pumps once the required system pressure is reached.

High-limit energy cut-out

Unit 333Poor circulation: air locks, blockages and pump faults

The overheat protection that shuts the heat source down if the water temperature rises too far, for example when circulation stops.

highest single appliance

Unit 331Pipe sizing from BS EN 806-3 tables and pump duty

The column in BS EN 806-3 Table 3 giving the largest single draw-off, in loading units, that a pipe size may feed however small its total load. It stops a 4 LU bath being fed through a size rated for a 2 LU appliance.

Hold period

Unit 334Applying the air test and reading the result

The time for which the test pressure must remain constant. For sanitary pipework it is at least 3 minutes.

Horizontal ground collector

Unit 335Ground collectors: trenches, slinkies, boreholes and ponds

Ground loop pipework laid in trenches a few metres below the surface. It is the cheapest collector to install where land allows, but needs a large area of ground.

Horizontal single-stage pump

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A centrifugal pump with one impeller on a horizontal shaft, for modest heads.

hose union backflow preventer (HA)

Unit 331Backflow devices: testing check valves and maintaining the RPZ valve

A small check valve screwed onto an outside tap to stop water siphoning back up a hose. It is tested by filling the hose from the tap, closing the tap and checking that the hose drains, and is replaced if it fails.

hose union tap

Unit 331Backflow protection levels: point of use, zone and whole site

A tap with a threaded outlet that a hose can be screwed onto, usually a bib tap outside a building. Because the hose end can lie in contaminated water it is a backflow risk: fluid category 3 in a house garden, protected by a double check valve inside the building, and category 5 in non-domestic premises.

Hot flush

Unit 333Cold flushing, hot flushing and the power flush

Running the system to maximum operating temperature and then draining it while hot, so that oils, flux residues and jointing compound are carried out with the water.

Hot water heating load

Unit 333Total heat load, hot water load and the boiler size

The heat input needed to reheat a stored hot water cylinder from the incoming cold temperature to the storage temperature within a chosen recovery time.

Hot water priority

Unit 333S-plan and S-plan plus: two-port valves and separate zones

A control arrangement in which a call from the cylinder closes the heating zones so that all the available output goes to reheating the stored water.

house exception

Unit 331Regulation 5 notification: the list and the ten working days

Item 2 of the Regulation 5 table makes extensions and alterations of a water system notifiable only in premises other than a house. The exception covers only item 2: the item 4 fittings, such as a large bath, a pump over 12 litres a minute or an RPZ valve, are notifiable in a house as anywhere else.

House in multiple occupation (HMO)

Unit 331Disinfection: which jobs need it and what disinfectant is used

A house shared by more than one household. It is not a single-family dwelling, so the disinfection exception does not apply.

HSE ACOP L8

Unit 331Design information: the Regulations, notification and BS EN 806

The Health and Safety Executive's Approved Code of Practice on the control of Legionella bacteria in water systems. It sets out the duty to assess and manage the risk in stored and warm water.

HSE Approved Code of Practice L8 (ACOP L8)

Unit 331Draining down, standing water and diagnostic readings

The Health and Safety Executive’s code on the control of Legionella bacteria in water systems. It sets the duty holder’s responsibilities in non-domestic buildings for risk assessment, monitoring and record keeping, and identifies 20 °C to 45 °C as the growth range.

Hybrid system

Unit 335Sizing, back-up and cycling: turning efficiency into savings

A heat pump and a boiler under a single intelligent controller, which selects whichever source is cheaper or more efficient at the current conditions.

Hydraulic accumulator

Unit 331Direct, indirect and boosted systems: extra checks and first fill

A pressure vessel with an air or nitrogen pre-charge that stores pumped water under pressure. It usually has one pipework connection and needs a check valve on its supply side.

Hydraulic capacity (Qmax)

Unit 334Discharge units, frequency factors and the flow rate formula

The flow in litres per second that a given size of pipe or stack can carry. The chosen pipe must have a hydraulic capacity at least equal to the calculated flow rate.

Hydraulic flush control valve

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A mechanical valve on a urinal supply that opens on a drop in hydrostatic pressure when other fittings are used, passing a measured amount of water to the cistern.

hydraulic impulse

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

A pressure surge, also called water hammer, set up when moving water is stopped suddenly, for example by a check valve slamming shut. It can damage fittings and cause noise.

Hydraulic impulse control

Unit 334Urinals: flush rates, controls and pressure flushing valves

A urinal flushing control that admits water to the cistern only when water is drawn from a nearby fitting, so flushing follows use.

hydraulic power

Unit 331Pipe sizing from BS EN 806-3 tables and pump duty

The power a pump puts into the water, in watts: flow in litres per second × 9.81 × head in metres. Dividing by the pump efficiency gives the motor power needed; 0.2 l/s at 17 m is 33 W, about 56 W at 60 per cent efficiency.

Hydraulic pressure test

Unit 333The pressure test, the pour and the 21 day cure

A leak test carried out with water raised by a test pump to a set pressure and held for a stated time. Underfloor circuits are tested before the screed goes down.

Hydraulic separation

Unit 333Multiple boilers, low loss headers and hydraulic separation

An arrangement in which two circuits exchange heat through a common vessel but not flow, so the pump on one side does not affect the flow rate on the other.

Hydraulic test

Unit 332Supply pressure and flow, and where the pipes run

A soundness test carried out with water rather than air, taking the system to one and a half times the maximum working pressure and checking for pressure loss and visible leakage.

Hydraulic test pump

Unit 331Soundness testing: current standards, equipment and procedure

The hand or powered pump used to raise a water-filled system to test pressure, with a calibrated gauge accurate to 0.2 bar at the lowest point.

Hydraulically short gutter

Unit 334Terraces, outlet positions and keeping a rainwater system working

A gutter whose length is not more than 50 times its design water depth. Longer gutters have their design capacity reduced by a capacity factor.

Hydrostatic pressure test

Unit 332Soundness testing: the Water Regulations tests

A pressure test carried out with water rather than air. Water is used because a failure releases very little stored energy, unlike compressed air.

immediate history

Unit 331Sources of fault information: the end user and the manufacturer

What the end user can tell you about a fault: when it first occurred, how it was noticed, whether it is constant or intermittent, any noises, any attempted repairs and what the result was. It is gathered by verbal discussion, not by measurement.

Immersion heater

Unit 332Choosing a hot water system: people, building and appliances

An electric heating element fitted into a hot water storage vessel. Used as a main heat source, as summer or backup heating, or to run a pasteurisation cycle.

impeller

Unit 331Sources of fault information: the end user and the manufacturer

The rotating vaned wheel inside a centrifugal pump that throws the water outwards and creates the pressure. If the shaft driving it breaks, the motor runs but no water moves and the outlets run dry.

Imposed load

Unit 335Roof structure and area: load, wind uplift and calculation

Load that comes and goes, such as snow on a roof, people, or stored water. It is assessed alongside dead and wind loads.

Improvement plan

Unit 336Dealing with poor work: informal action and the formal procedure

A written record of what was wrong, what standard is required, what support is offered, and when performance will be reviewed.

in situ

Unit 331Reading drawings: elevations, sections, specifications and site surveys

In its actual place; a measurement taken in situ is taken in the building itself rather than off a drawing. Needed where there are no drawings, or where the drawing and the building disagree.

In-line blending valve

Unit 332Limiting outlet temperature: bath limits and TMV types

A mixing valve fitted in the pipework rather than at the tap, used to hold the hot water supplied to an appliance such as a bath below its maximum temperature.

In-line filter

Unit 333Cleansers, neutralisers, inhibitors and the in-line filter

A device fitted permanently in the system water circuit, commonly using a magnet, that captures and allows the removal of circulating solid particles.

In-line strainer

Unit 332Siting the cylinder: weight, clearance and the discharge route

A removable mesh filter fitted on the cold supply to an unvented cylinder to catch debris before it reaches the control valves. It has to be accessible for cleaning.

In-progress inspection

Unit 336Quality checks: allocating areas, inspecting and testing

Inspection and checking of work while it is being carried out, recorded so there is evidence of the check once the work is covered.

Independent time control

Unit 333Zoning: how many zones, and what each one controls

A separate time channel for a circuit, so that its on and off times can be set without affecting any other circuit.

Index circuit

Unit 333Pump duty: the index circuit, head and the duty point

The circuit in a system with the greatest total resistance to flow, normally the longest run to the most remote emitter. The pump is sized from it.

Indirect boosting

Unit 331Multi-storey supply: the mains limit and the break cistern

Boosting where the pumps draw from a break cistern rather than the supply pipe, so there is no limit on pump capacity.

Indirect cylinder

Unit 332Direct, indirect and combination cylinders compared

A hot water storage vessel containing a heat exchanger, so that primary water from the boiler heats the stored secondary water without mixing with it.

Indirect distribution

Unit 335Rainwater harvesting: collection, filtration and storage

Distribution in which harvested water is pumped to a cistern at high level, which then supplies the outlets by gravity and receives the mains top-up.

Indirect system

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A cold water system where the outlets, apart from the drinking tap, are fed from a storage cistern.

Induced interference

Unit 333Running the cables and wiring the control system

Unwanted electrical noise picked up by a signal cable from a nearby mains cable, which can make sensor readings drift or jump.

Induced siphonage

Unit 334Traps, seal depths and how a trap loses its seal

Loss of the seal from a trap that is not in use, caused by suction from another appliance discharging into the same branch or stack.

Informal action

Unit 336Dealing with poor work: informal action and the formal procedure

Dealing with a first or minor performance problem by private conversation, agreeing the standard and setting a review, without invoking the formal procedure.

Infra-red operated tap

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A hands-free tap whose sensor eye opens a solenoid valve when the beam is broken by the users hands. Runs on 6 V DC.

Infrared operated tap

Unit 332Specialist taps and outlet fittings: how they work

A tap opened by breaking an infrared sensor beam, which signals a solenoid valve to pass water for as long as the beam is interrupted.

inhibitor

Unit 331Filling loops and outside taps: protecting heating and garden connections

A chemical added to heating system water to slow corrosion and scale. A large system dosed with inhibitor outside a house is fluid category 4, so a permanent fill to it needs a type BA RPZ valve.

Initial heating up

Unit 333Underfloor pipework: patterns, insulation, screed and testing

The controlled first warming of a heated screed: 20 to 25 °C for at least 3 days after the curing period, then the design temperature for at least 4 more days.

Initial notice

Unit 334Notifying building control: notices, full plans and competent persons

A notice given jointly by the client and an approved inspector, transferring the building control function from the local authority to that inspector.

Initial verification

Unit 333Dead tests and live tests: the order and the instruments

The inspection and testing carried out on a new installation, or an addition or alteration, before it is put into service. It is set out in Part 6 of BS 7671.

Injector valve

Unit 333The underfloor manifold: blending, balancing and safety

A two-port valve that meters hot primary water into a recirculating manifold circuit to hold the blended temperature, as an alternative to a three-port mixer.

Inlet control group

Unit 332The unvented inlet control group and its order

The set of valves fitted in order on the cold supply to an unvented cylinder: isolating valve, line strainer, pressure reducing valve, single check valve, expansion vessel connection and expansion relief valve.

inlet group

Unit 331RPZ valves and single and double check valves

The set of controls on the cold feed to an unvented cylinder: a line strainer, pressure-reducing valve, single check valve, expansion relief valve and often the expansion vessel connection, usually in one assembly. The check valve stops expanded hot water flowing back into the supply.

Insect screen

Unit 331Large cisterns: warning pipes, overflows and inlet valves

Corrosion-resistant mesh of 0.65 mm maximum aperture over cistern vents and overflows to keep insects out.

Insolation

Unit 335The solar resource: irradiance, insolation and the seasons

The solar energy accumulated on a surface over a period, measured in kilowatt hours per square metre. Also called irradiation.

Inspection (BS 7671)

Unit 333Before commissioning: the documents, the conditions and the inspection

The visual examination of an electrical installation, carried out before testing and normally with the supply disconnected, to verify correct selection, erection and condition.

installation specification

Unit 331Design information: manufacturer data, customer feedback and scale plans

The document describing the installation to be priced and built: the materials, the appliances, any manufacturer or British Standard they must meet, and the performance the system must deliver such as flow rates and pressures at outlets. Read with the manufacturers' data it defines what the design calculation has to achieve.

Instantaneous water heater

Unit 332Centralised and localised hot water: choosing between them

A heater with no storage that heats water as it flows through. It delivers hot water for as long as the tap runs, but only while water is flowing.

Instrument calibration

Unit 333Testing the finished controls: earth continuity and polarity

The periodic checking of a test instrument against a known reference so its readings can be relied upon, and recorded so results can be defended.

Insulation resistance

Unit 333Dead tests and live tests: the order and the instruments

The resistance measured between conductors, or between conductors and earth, at a raised DC test voltage. It shows whether the insulation has broken down. Minimum 1 megohm at 500 V DC on a 230 V circuit.

Insulation resistance test

Unit 334Commissioning a WC macerator: the checks before power on

An electrical test that confirms there are no low resistance paths between circuit conductors, or between conductors and earth.

Interceptor trap

Unit 334Air admittance valves, stack terminations and housing sites

A trap built into an inspection chamber on a drain to stop sewer gases and vermin passing towards the building. A drain with one needs an open ventilating pipe, not an AAV.

Interim payment

Unit 336Cost and quantities: estimator and quantity surveyor

A payment made to a contractor during a contract, based on the work measured and valued up to that date.

Interim test

Unit 331Soundness testing: current standards, equipment and procedure

A pressure test on a section of work as it proceeds, especially work that will be concealed or buried; it does not replace the final test.

Interlinked cisterns

Unit 331Linked and sectional cisterns in the plant room

Two or more cisterns of the same size piped together to provide the total storage, arranged so water flows through all of them.

intermittent fault

Unit 331Sources of fault information: the end user and the manufacturer

A fault that comes and goes rather than being present all the time, for example a noise heard only while a WC cistern refills. It is harder to find because it may not be there when you arrive, so the user's account of when it happens matters.

Intermittent heating allowance

Unit 333Working a room: a fabric and ventilation heat loss

An addition of about fifteen per cent to a calculated heat loss to allow for the system running only at set times, so rooms can be brought back up to temperature quickly.

Internal customer

Unit 336Types of client: private, contracting and internal

A department or section within the same company or organisation that raises work for the in-house team to carry out.

Internal design temperature

Unit 333Design temperatures: inside, outside and the difference

The temperature a room must reach when the heating system is running. It is chosen from the room's use and agreed with the customer.

Internal expansion

Unit 332Expansion on an unvented system: vessel, valve and balanced cold

An arrangement in which the expansion is taken by an air pocket at the top of the cylinder, held above a floating baffle plate. Known as a bubble top cylinder.

Internal expansion bubble

Unit 332The three fault signatures and what each one means

An air gap held at the top of some unvented cylinders that takes up expansion instead of an external vessel. The air slowly dissolves into the water and the gap must be recharged by draining down and refilling.

Internal overflow

Unit 334WC flushing: volumes, devices and overflow protection

An arrangement that discharges excess water from a cistern into the pan rather than through an external warning pipe. It is accepted only where a strainer is fitted at or upstream of the float-operated valve.

Intumescent fire collar

Unit 334Fire stopping, access and notification

A collar fitted round a plastic pipe where it passes through a fire separating element. In a fire the intumescent material expands and crushes the softening pipe closed, sealing the opening.

Invert

Unit 331Large cisterns: warning pipes, overflows and inlet valves

The lowest point of the inside of a pipe; the level from which warning pipe and overflow heights are measured.

Inverter-driven compressor

Unit 335Monovalent, bivalent systems, buffers and system volume

A compressor whose speed can be varied to match the heat demand, instead of running at full output or stopping.

Invoice

Unit 336Spoken, written and drawn: choosing the right method

The document issued at the end of a contract demanding final payment for the work carried out.

Irradiance

Unit 335The solar resource: irradiance, insolation and the seasons

The rate at which solar radiation falls on a surface, measured in watts per square metre. It is an instantaneous power, not a total.

Isolating valve

Unit 333The circulating pump: position, isolating valves and unions

A valve fitted so that a component can be shut off and worked on without draining the system. Pumps have one on each side.

isolation

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

Shutting off the water — and on a boosted system the electricity — to the part of the system being worked on, making sure it stays off, and telling people why. The sequence is isolate, label, leave contact details, cap off.

isolator

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The switch that disconnects the electrical supply to a pump set or control panel. It is switched off, proved dead, locked off and labelled before any mechanical work starts.

isometric

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A three-dimensional drawing of pipework in which the three axes are drawn at 30° to the horizontal so vertical and horizontal runs can both be shown. The isometric used for pipe sizing is best drawn to scale, with each junction numbered, as the withdrawn BS 6700 (Annex D) recommended.

Isometric drawing

Unit 331Handover: the file and the demonstration

A three-dimensional projection of the pipework used for setting out; a projection, not a record of what was installed.

Job sheet

Unit 336Programmes for private work: installations and service jobs

The record of a single visit, listing the work carried out, parts used and time taken.

Job specification

Unit 336Spoken, written and drawn: choosing the right method

A written description of the installation being priced, giving the types, models and quality of materials and appliances, and often the British Standard to be met.

jointing compound

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A paste applied to screwed pipe threads to make them watertight; for drinking water it must be to BS 6956 Part 5 so it does not taint the water. PTFE tape, the thin plastic tape wound round a thread for the same purpose, is made to BS 6974.

jumper plate

Unit 331Sources of fault information: the end user and the manufacturer

The disc inside a screw-down tap that carries the washer and sits on the seat. If it is loose it chatters in the flow, so the tap vibrates and gives a poor flow.

Junction box

Unit 333Terminations and joints: making the connection last

An enclosure containing terminals for joining cables. In heating work it is used for control wiring on a circuit that already has adequate fuse protection, not to supply equipment straight from a main circuit.

Just in time supplies

Unit 336Resources: labour, materials, plant and vehicles

Materials delivered to the exact location of the work at an agreed time that coincides with the operatives starting that work, so nothing is stored on site longer than necessary.

Just-in-time delivery

Unit 336Ordering plant and materials, and checking what arrives

A method of supply in which materials arrive at the exact location of the work at a time that coincides with the operatives beginning that work.

Kelvin (K)

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

The unit used in the standards for a temperature difference; a difference of 10 K is the same as 10 degrees Celsius.

Kettling

Unit 333Emitter cold spots: air at the top, sludge at the bottom

Banging or rumbling boiler noise caused by scale or sludge on the heat exchanger, which makes water boil locally against the fouled surface.

Kilowatt hour (kWh)

Unit 332Recovery rate, reheat time and usable volume

A unit of energy: one kilowatt delivered for one hour. Dividing kilojoules by 3600 converts them to kilowatt hours.

Kinetic ram

Unit 334Blockages: where they form and how they are cleared

A gun that drives compressed air against a column of water to send a shock wave at a blockage. Used only on compacted soft material, and never where air admittance valves are permanently fixed.

Knuckle bend

Unit 334Air admittance valves: the conditions they need to work

A sharp, short-radius bend with no sweep. It restricts flow and, at the head of a stack, leaves an air admittance valve sitting off vertical.

kPa

Unit 331Cistern sizing, float valve refill and pipe design limits

Kilopascal, the SI unit of pressure used in BS EN 806. 100 kPa is 1 bar and is roughly the pressure of 10 m of water; 500 kPa is 5 bar.

Labour input

Unit 336Work programmes: what they are and what they show

The number of people, and the hours they work, allocated to an activity. A bar chart carries a space to record it.

Labour resource

Unit 336Resources: labour, materials, plant and vehicles

The people available to do the work, expressed as the number of operatives and the periods for which they are needed.

Laceration

Unit 336Manual handling: avoid, assess and reduce

A cut or tear of the skin, the typical injury from handling thin sheet metal casings, cut pipe ends and broken cast iron.

lagging

Unit 331Sources of fault information: the end user and the manufacturer

Insulation wrapped round pipework and cisterns to stop heat loss, frost damage and cold water warming up, and to stop pipes vibrating against the structure. Pipes under floorboards that are not lagged are a common source of noise.

Landing point

Unit 336Work at height: ladders, harnesses and the definition

The place a person steps off a ladder onto a platform, floor or loft. The ladder must extend at least a metre above it to give a handhold.

laser measure

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A hand-held instrument that measures a distance by bouncing a laser off a surface, accurate to about 3 mm, used by one person and unaffected by sag or obstacles. The most accurate site measuring instrument.

Latent heat

Unit 333Heat gains, pipework losses and what the design ignores

Heat involved in a change of state, such as the evaporation of moisture from skin and breath, without a change in temperature. A person at rest gives off about 50 watts of it.

Lawful development certificate

Unit 335Permitted development: what it means, and solar on a roof

A certificate from the local planning authority confirming in writing that proposed work is lawful without planning permission.

Layout drawing

Unit 332Drawings, manufacturer instructions and the customer brief

A drawing that shows components in their true physical positions on the plan of the building. Used to find where appliances and vessels are to go.

Lead time

Unit 336Materials changes: substitutions, discrepancies and damaged goods

The time between placing an order and the goods being available. A long lead time on a specified item is a common cause of programme pressure.

lead-free solder

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

Solder for joining copper pipe on water services that contains no lead, made to BS EN 29453. Lead solder is banned on drinking water pipework because lead dissolves into the water; lead-free solder is tin with a little copper or silver.

Leak detection fluid

Unit 332Expansion vessels and air gaps: checking and recharging

A soap-based solution brushed onto a joint or valve so that escaping gas or air forms visible bubbles. Used to confirm whether a Schrader valve is leaking.

Leak-detection valve

Unit 331Balancing, mechanical controls and functional testing

An automatic shut-off valve that closes on detecting a leak, functionally tested like any other control.

Legionella

Unit 331Design information: the Regulations, notification and BS EN 806

The bacteria that cause Legionnaires' disease, a serious pneumonia caught by breathing in fine water droplets. They multiply in stagnant water between about 20°C and 45°C, which is why cold water is kept below 20°C, storage is kept small and dead legs are avoided.

Legionella pneumophila

Unit 332Design temperatures: storage, flow, return and outlet

The bacterium that causes Legionnaires' disease. It is contracted by inhaling an aerosol of contaminated water and multiplies between 20 and 45 degrees C.

level 3 on the standard scale

Unit 331The Water Regulations: origin, enforcement and the five harms

The maximum fine for an offence under the Water Fittings Regulations, set by Regulation 7. The standard scale is the set of fine levels used by magistrates' courts; level 3 is currently 1,000 pounds.

Level access

Unit 334Wet rooms: tanking, falls and the floor gully

An arrangement with no step or threshold to cross, which is why a wet room suits users with limited mobility.

Level alarm device

Unit 331Large cisterns: warning pipes, overflows and inlet valves

A level-sensing device with an audible or visual alarm that may replace the warning pipe on cisterns over 5,000 litres.

Level control

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Running a private supply pump from a float switch in the roof cistern, so every outlet is cistern fed at low pressure.

Lever tap

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A tap with a long lever that can be worked with the wrist or elbow, chosen where hands must not touch the tap.

Liability

Unit 336Variation orders: pricing a change the client asks for

Legal responsibility for a cost or a loss. Where a variation results from defective workmanship, liability for the extra cost can fall on the contractor.

Lift

Unit 333Fuel, efficiency and environmental impact of the choice

The temperature gap a heat pump must bridge, from its source temperature up to the flow temperature it delivers. Widening the lift reduces efficiency.

Like for like

Unit 333Rectifying, re-commissioning and handing back

Replacing a component with one of the same specification. Where that is not possible, the manufacturer confirms the alternative is approved.

like-for-like

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

Replacing a failed part with the same make and model, or with the manufacturer’s own spare, so that the component performs exactly as designed and its approvals and warranty are unaffected.

Like-for-like replacement

Unit 332Isolating, decommissioning, rectifying and handing back

Replacing a failed component with one of the same type, rating and capacity, or with a part the manufacturer has confirmed is approved for use with that appliance.

Likelihood

Unit 336Ranking the risk: likelihood times severity

The judged chance of an accident occurring, scored on a scale running from no likelihood through unlikely and likely to certainty.

Limescale

Unit 333Emitter cold spots: air at the top, sludge at the bottom

Calcium carbonate deposited from hard water in the hottest part of the system, usually the boiler heat exchanger, where it reduces heat transfer.

Limit of mains pressure

Unit 331Multi-storey supply: the mains limit and the break cistern

The height up a building that the water main can serve on its own. Floors above it need pumping.

Limit specific thermal output

Unit 333Underfloor heating: floor temperatures, output and comfort

The maximum heat a floor heating system may give per square metre, fixed by the maximum permitted surface temperature. 100 W/m² in occupied areas and 175 W/m² in peripheral areas.

Limiting U-value

Unit 333Flow temperature: the number that governs running cost

The worst U-value a new element may have and still comply, sometimes called the backstop. It is a floor, not a target: the value actually built to is normally better.

Limits of authority

Unit 336Craft levels and allocating work: who supervises whom

The boundary of what a person at a given level of qualification and responsibility may decide or do without referring it upwards.

Line drawing

Unit 334Materials, line drawings and quotations for a dwelling

A simple diagram, not drawn to scale, showing appliances, pipe runs and their sizes as single lines. It is the industry convention for presenting a sanitary pipework design to a customer.

line strainer

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

A mesh filter fitted in the pipe immediately upstream of a category 4 backflow device such as an RPZ valve to keep grit out of its check valves. A gradual loss of flow downstream usually means the strainer is blocked.

Linear drain

Unit 334Wet rooms: tanking, falls and the floor gully

A long narrow floor gully, often set against a wall, that collects shower water across its length instead of at a single point.

Listed building

Unit 335Permitted development: what it means, and solar on a roof

A building on the statutory list because of its special architectural or historic interest. Work to it needs consent, and permitted development rights do not apply.

Live document

Unit 336Using a method statement on site

A document that is kept current and available where the work is happening, updated as the job changes rather than filed once and forgotten.

Live test

Unit 333Dead tests and live tests: the order and the instruments

A test that requires the circuit to be energised, such as earth fault loop impedance, prospective fault current and RCD operation. Only competent, skilled persons carry these out.

Load

Unit 336Manual handling: avoid, assess and reduce

The object being handled. In the regulations a load may be inanimate, such as a box or a boiler, or animate, such as a person or an animal.

Load compensation

Unit 333Weather compensation, optimum start and home automation

A control function that varies the flow temperature from the heat generator according to the measured response of the heating system.

loading unit (LU)

Unit 331Available pressure and flow, feed arrangements and loading units

A number given to each type of outlet that allows for its flow rate, how long it runs and how often it is used, so that the outlets on a pipe can be added up and converted to a design flow. In BS EN 806-3 one loading unit equals 0.1 l/s: basin and WC 1, sink and shower 2, bath 4, garden tap 5.

local authority

Unit 331The Water Regulations: origin, enforcement and the five harms

The district, borough or unitary council. In water work it enforces the Private Water Supplies Regulations, inspecting and testing private supplies, and enforces the Building Regulations through its building control department; it does not enforce the Water Fittings Regulations, which is the undertaker's job.

Local isolation

Unit 333Supplying and isolating the controls on site

A switch or fused connection unit at or beside the equipment, allowing it to be switched off for servicing without disturbing other circuits in the building.

Localised hot water system

Unit 332Centralised and localised hot water: choosing between them

A system in which a small heater is fitted at the outlet it serves. Also called a single point or point of use system.

Localised repair

Unit 331Disinfection: which jobs need it and what disinfectant is used

A small repair or an inserted junction in an existing pipe. The fitting is immersed in disinfectant before fitting rather than the whole system being disinfected (BS EN 806-4 clause 6.3.5).

Lock off

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

Securing an electrical isolator in the off position with a lock, after proving the circuit dead, so it cannot be switched on while work goes on.

Lock-off device

Unit 333Safe isolation: the seven steps in order

A proprietary fitting that holds a circuit breaker or switch in the off position so a padlock can be applied and the supply cannot be restored by anyone else.

lockable head

Unit 331Identifying non-wholesome pipework and testing for cross connections

A hose union tap on a non-wholesome supply fitted with a head that locks or can be removed, so it cannot be used by mistake. It is preferred to a label because it does not depend on anyone reading it.

Lockout

Unit 333Heat pump fault patterns: temperature difference and pressures

A protective shutdown by an appliance, which then stays off until it is reset. The code shown says which protection operated.

Lockshield valve

Unit 332Secondary circulation: pump position, balancing and controls

A regulating valve with a shielded head so its setting cannot be altered by hand, used to balance the branches of a circulating system during commissioning.

logbook

Unit 331System history: commissioning records, logbooks and inspection frequencies

The book kept on site, usually in the plant room, in which every inspection, test, maintenance visit and repair on the installation is recorded. BS 8558 expects one for a boosted installation, and PD 855468 calls the version used for Legionella control the water management logbook.

Loop

Unit 333Underfloor heating faults: the manifold, the loops and a hot floor

One continuous circuit of underfloor pipe serving an area, connected to the flow and return manifolds.

Low loss header

Unit 333Multiple boilers, low loss headers and hydraulic separation

A large-bore vessel connected across the boiler circuit and the heating circuits, giving hydraulic separation so each side can run at its own flow rate.

Low pressure switch

Unit 331Booster sets: the pressure vessel and the control switches

The pressure switch set at the cut-in pressure that starts the pumps as water is drawn and the pressure falls.

low resistance ohmmeter

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

An instrument for measuring very small electrical resistances accurately, used across disconnected motor leads to test the winding resistance. It is only used after safe isolation.

Low surface temperature (LST) radiator

Unit 333Filling the system before the controls are proved

A radiator with a casing over the heating element that keeps the touchable surface much cooler than the water inside, for locations used by children, the elderly or the infirm.

Low surface temperature radiator (LST)

Unit 333Emitter load: correcting catalogue output to real conditions

A radiator with a casing designed to stay cool enough not to burn on contact. It is used in nurseries, schools, care settings and anywhere vulnerable people may touch it.

Low-level break cistern

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A break cistern, inside or outside the house, that collects water from a source below the house or an unreliable one, from which a surface pump lifts it.

Low-level float switch

Unit 331Direct, indirect and boosted systems: extra checks and first fill

A switch in the break cistern that stops the pumps when the water is low, preventing dry running.

Low-level probe

Unit 331Borehole pumps: packaged sets, controls and the accumulator

An electrode in a borehole or cistern that senses when the water has dropped too low and stops the pump, doing the job of a float switch where a float will not fit.

Low-pressure taps

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

Taps designed for cistern-fed supplies with a full-bore waterway, fitted in place of high-pressure taps to cure poor flow on a gravity system.

Low-resistance ohmmeter

Unit 333Dead tests and live tests: the order and the instruments

An instrument that can measure very small resistances accurately, used for continuity and polarity testing. Its leads are nulled before use.

Macerator

Unit 334WC macerators: how they work and how the outlet runs

A pumped unit fitted behind a WC that shreds solids with rotating blades and pumps the liquid mixture through small bore pipework to a stack or drain.

Magnetic toggle float switch

Unit 331Booster sets: the pressure vessel and the control switches

A float switch in which repelling magnets snap a micro-switch over as the float passes the set level, so the contacts change cleanly.

Magnetite

Unit 333Filling and venting a metallic or plastic heating system

Black iron oxide sludge formed by corrosion in a heating system. It settles in low flow areas, blocks heat exchangers and seizes pumps.

Main contractor

Unit 336The chain of command: who can give you an instruction

The contractor holding the contract with the client for the building work as a whole. It appoints and co-ordinates the subcontractors.

Main drain

Unit 334Air admittance valves, stack terminations and housing sites

The drain run serving a building or a group of buildings before it reaches the sewer. Approved Document H requires a ventilating pipe at or near its head.

Main earthing terminal (MET)

Unit 333Earthing and bonding a heating control circuit

The terminal or bar in an installation to which the earthing conductor, the circuit protective conductors and the main bonding conductors are all connected.

Main protective bonding conductor

Unit 333Earthing and bonding a heating control circuit

A conductor connecting the main earthing terminal to incoming metallic services such as water and gas, so that all touchable metalwork sits at a similar potential.

mains back-up

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The wholesome water top-up that keeps a rainwater or greywater system working in dry weather. It enters the storage cistern or make-up module through a type AA or AB air gap above the water, never by a pipe-to-pipe connection, so only the water meets and the pipes never join.

Mains loss allowance

Unit 333Flow rate and pipe size: from kilowatts to millimetres

The percentage added to a pipe section's heat duty to cover the heat the pipe itself gives up on the way, typically 5 to 10 per cent depending on the length of run.

Mains pressure cleaning

Unit 333Cold flushing, hot flushing and the power flush

Circulating the cleaner, then flushing the system and each radiator in turn with mains pressure water until it runs clear, using a backflow prevention device at the mains connection.

mains-fed system

Unit 331Available pressure and flow, feed arrangements and loading units

A cold water system in which every outlet is fed direct from the supply pipe at mains pressure, with no storage cistern. Also called a direct system. A combined system puts the kitchen sink on the supply pipe and the rest on a cistern, so the cistern buffers peak demand.

maintenance

Unit 331Regulations 3 and 4: installer tests and user duties

Keeping water fittings in working order so they do not become damaged, worn or faulty. Under Regulation 3 it is the user's responsibility, and failing to maintain a fitting that then causes waste or contamination is a contravention by the user.

Maintenance log

Unit 334Manufacturer data, fault charts and documented history

The running record of maintenance work on a plant. BS EN 12056-4 clause 8.2 says a log should be kept of all maintenance work, detailing what was carried out.

Maintenance schedule

Unit 333Notifying the client, safe isolation and temporary decommissioning

The record on which maintenance and repair work is entered as it is completed, giving location, date and tests performed.

Major extension or alteration

Unit 331Disinfection: which jobs need it and what disinfectant is used

Substantial new pipework added to an existing system, treated as a new system for disinfection (PD 855468 clause 9).

Making good

Unit 334What a sanitation commissioning record must contain

Repairing the defects that testing has revealed, and restoring anything opened up to reach them, before the results are finally recorded.

Management arrangements

Unit 336Presenting a method statement: headings and format

The section of a method statement stating how supervisors and managers will make sure the working methods are actually followed, including regular team meetings.

Management of Health and Safety at Work Regulations 1999

Unit 336The regulations that sit under the Act

Regulations requiring employers to make a suitable and sufficient assessment of the risks from their work activities, and to give particular attention to young persons before employing them.

Managing agent

Unit 336Types of client: private, contracting and internal

A firm appointed to manage a property on the owner's behalf. It instructs work, agrees prices and arranges access as the owner's representative.

manifold

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The common pipe header that several pumps share on their suction side and again on their discharge side, with an isolating valve and a non-return valve for each pump.

Manifold isolation ball valve

Unit 333The underfloor manifold: blending, balancing and safety

A quarter-turn valve at the end of each manifold bar allowing the manifold to be isolated for maintenance without draining the system.

Manometer

Unit 334The air test requirement: 38 mm water gauge for 3 minutes

A U-shaped tube part filled with water, used to read very small pressures. The difference between the two water levels is the pressure in millimetres water gauge.

Manual Handling Operations Regulations

Unit 336Manual handling: avoid, assess and reduce

Regulations covering lifting, lowering, pushing, pulling and carrying. They require hazardous handling to be avoided, then assessed, then reduced so far as is reasonably practicable.

Manufacturer technical instructions

Unit 333The documents a designer works from, and which one wins

The installation, commissioning and maintenance instructions for a specific appliance. Where they demand more than a standard, they govern, unless statute requires otherwise.

Manufacturer's installation instructions

Unit 332Drawings, manufacturer instructions and the customer brief

The technical document supplied with an appliance. It carries the required supply conditions, pipe sizes, heat input, controls, discharge sizing and fault-finding data for that specific model.

Manufacturer’s installation instructions

Unit 333Checking the existing installation before you connect

The document supplied with an appliance setting out how it must be installed, supplied, commissioned and maintained. It is followed where it is more demanding than a general standard.

Manufacturer's instructions

Unit 334Interpreting the information before commissioning starts

The installation, commissioning and maintenance document supplied with an appliance. It gives the setting-up procedure and the performance figures for that model.

manufacturer’s instructions (manufacturer’s data)

Unit 331Sources of fault information: the end user and the manufacturer

The literature the manufacturer supplies with a component — installation, operating, commissioning and maintenance instructions, fault-finding charts and parts lists. It is the first document to consult when diagnosing a fault on a component, and BS EN 806-5 requires it to be kept and followed.

manufacturer's technical instructions

Unit 331Design information: manufacturer data, customer feedback and scale plans

The data sheets and installation instructions supplied with an appliance or component, giving its minimum flow rate, working pressure, connections and commissioning procedure. They give the figures for the item actually being fitted, and ignoring them voids the warranty and can put the installer in breach of the Regulations.

Manufacturers' instructions

Unit 331Visual inspection: the documents and the dry checklist

The installation, set-up and commissioning instructions supplied with each component. They must be followed; ignoring them can void the warranty.

Mark-up

Unit 336Building a price: a worked example

The percentage added to the cost of a job to produce the selling price, covering overheads and profit.

Mass flow rate

Unit 332Sizing a secondary circulation

The mass of water moving past a point each second, in kg/s. On a secondary return it is found from the heat the loop loses: kW divided by the specific heat capacity of water (4.19 kJ/kg·K) times the temperature drop.

Material alteration

Unit 334Building Regulation Parts and the notice the law requires for drain work

A change to a building or to a controlled service or fitting that affects compliance with the Building Regulations. Material alterations to drains and sewers are covered by the Regulations.

material change of use

Unit 331Fluid categories: grading water and regrading a building

A change in the purpose for which, or the circumstances in which, premises are used, so that they become a dwelling, an institution, a public building, or somewhere storing substances that would form fluid category 4 or 5. It ends the exemption for fittings installed before 1 July 1999 and is itself notifiable to the water undertaker.

Materials take-off

Unit 336Pricing methods: take-off, bills of quantities and rates

The process of measuring and counting the materials required for a job directly from the drawing, listed by type and size.

Maximum demand

Unit 333Checking the existing circuit: rating, condition and damage

The greatest current an installation or circuit is expected to draw at one time. It is assessed under BS 7671 Section 311 and is the basis for deciding whether an installation can take extra equipment.

Maximum design pressure

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

The highest pressure an appliance or fitting is made to work at; a PRV is needed where the supply can exceed it.

Maximum loss of seal

Unit 334Performance testing a branch pipe for self-siphonage

The largest reduction in trap seal depth measured across the repeats of a test. It is compared against the 25 mm criterion.

Maximum operating pressure

Unit 331Soundness testing: test pressures for metal and plastics pipework

The highest pressure the installation is designed to be subjected to in operation, normally the mains pressure after any pressure reducing valve. The test pressure is 1.5 times this.

maximum section length

Unit 331Pipe sizing from BS EN 806-3 tables and pump duty

The length limit in BS EN 806-3 Table 3 for the smaller pipe sizes: 15 mm copper carries 4 LU only up to 9 m and 6 LU only up to 7 m. Beyond the limit the section goes up a size.

Maximum storage period

Unit 335Greywater re-use: sources, treatment and storage limits

The longest time a greywater system may hold treated water, declared by the manufacturer. When it is exceeded the water must be discharged and replaced.

Maximum working pressure

Unit 332Soundness testing: the Water Regulations tests

The highest pressure the installation is designed to be subjected to in normal operation, usually the incoming mains pressure after any pressure reducing valve.

MCS 020

Unit 335Heat pumps and permitted development: volume, boundary and noise

The Microgeneration Certification Scheme planning standard used to assess noise from an air source heat pump at a neighbouring property.

Mean water temperature (MWT)

Unit 333Emitter load: correcting catalogue output to real conditions

Half the sum of the flow and return temperatures of an emitter. Subtracting the room temperature from it gives the excess temperature that sets the emitter's output.

Means of isolation

Unit 333Operational checks: the vessel, the controls and the electrical work

The device that safely disconnects the appliance and its controls from the supply for both electrical and mechanical safety. Its presence and operation are confirmed at commissioning.

measuring wheel

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A wheel on a handle that counts its turns as it is pushed along the ground to read a distance. Used for long external runs; more accurate than pacing, a folding rule or scaling off a plan.

Mechanical aid

Unit 336Manual handling: avoid, assess and reduce

Equipment used to take the weight out of a handling operation, such as a sack truck, skates, a trolley, a tail lift or a lifting device.

mechanical backflow prevention device

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

A backflow device with moving parts, such as a check valve, RPZ valve or disconnector, that puts a physical barrier in the pipe where an air gap cannot be arranged. Mechanical devices wear, need access and testing, and none of them reaches fluid category 5.

Mechanical controls

Unit 331Balancing, mechanical controls and functional testing

The float valves, servicing and stop valves, pressure reducing valves, backflow devices and booster controls that are set to the specification and manufacturer's figures at commissioning.

Mechanical damage

Unit 333Damaged cable: recognising it and putting it right

Physical injury to a cable such as crushing, cutting, abrasion or crimping of the sheath or insulation. It is one of the things a pre-installation inspection looks for.

Mechanical filter

Unit 331Direct, indirect and boosted systems: extra checks and first fill

A strainer fitted on the filling connection of a large job so that the filling water is free of particles of 150 micrometres or larger.

Mechanical isolation

Unit 334Safe isolation before working on powered sanitary components

Securing the water supply and the flow into a component or section of pipework, so nothing can discharge into it while work or testing goes on.

Meltwater drainage route

Unit 333Servicing a heat pump: coil, defrost and the water side

The path taken by water shed during defrost, from the base of the outdoor unit to a drain or soakaway. If it blocks, the water refreezes at the unit.

Method of work

Unit 336Presenting a method statement: headings and format

The section of a method statement giving the site-specific sequence of work and the actual methods used to keep work areas safe and tidy at each stage.

Method statement

Unit 331Visual inspection: the documents and the dry checklist

A written description of how a job will be done safely, held with the risk assessment and any permit to work.

mg/l (ppm)

Unit 331Chlorine disinfection: the figures, the people and the samples

Milligrams per litre, the concentration unit for chlorine; one mg/l is one part per million.

Micro bore

Unit 333Flow rate and pipe size: from kilowatts to millimetres

Small diameter heating pipework, typically 8 mm or 10 mm, run from a manifold to individual emitters. It may be sized to a velocity of up to 1.5 m/s.

Micro combined heat and power (micro-CHP)

Unit 333Multiple boilers, low loss headers and hydraulic separation

A heating appliance containing an engine or fuel cell that generates electricity while it produces heat for the dwelling.

Micro-renewable energy system

Unit 335The pre-installation survey: deciding whether a job can go ahead

A small-scale system generating heat or power from a renewable source for a single building, such as solar thermal or a heat pump.

Micro-renewable technology

Unit 335Micro-renewable technologies: what each one produces

A small-scale renewable energy system sized for a single building. It either produces heat, produces electricity, or produces both.

Micro-switch

Unit 331Booster sets: the pressure vessel and the control switches

A small snap-action electrical switch operated by a float, flow paddle or lever, used inside float switches and flow switches.

Micro-wind turbine

Unit 335Micro-renewable technologies: what each one produces

A small wind turbine, pole mounted or building mounted, that generates electricity. Siting depends on average wind speed, turbulence, height, and noise and vibration.

Microbiological contamination

Unit 331Private water supplies: sources and responsibilities

Bacteria and other micro-organisms in water, the main risk from shallow streams and springs, dealt with by disinfection.

Microbore heating system

Unit 333Microbore systems: manifolds, pipe sizes and circuit limits

A two-pipe heating system whose circulation pipework is normally 6 mm to 12 mm outside diameter, fed from a pair of manifolds. Radiator legs are usually 8 mm or 10 mm.

Microgeneration Certification Scheme (MCS)

Unit 335Law, standards and schemes: what MCS is and is not

A certification scheme for small-scale renewable technologies and their installers. It is voluntary in law but is normally required for grant funding.

Mid position

Unit 333Y-plan and W-plan: mid-position against diverter

The position of a three-port mid-position valve in which both outlet ports are partly open, so heating and hot water are served together.

Mid-position valve

Unit 333Zone valves: two-port, mid-position and diverter

A three-port valve that can direct flow to the heating, to the cylinder, or share it between both at once. Used in the Y-plan arrangement.

Mini expansion vessel

Unit 331Check valves, water hammer and the mini expansion vessel

A small vessel fitted on the closed side of a check valve, between the valve and the heater, to take up the expansion of water that warms in the closed section.

minimum flow rate

Unit 331Available pressure and flow, feed arrangements and loading units

The flow an outlet must still receive when other outlets are in use at the same time, lower than its design flow rate. BS EN 806-3 gives 0.15 l/s for a sink and 0.3 l/s for a bath, for example.

Minimum system volume

Unit 333System volume, buffers and short cycling

The least volume of water that must remain in circulation for a heat generator to run without cycling too frequently. It is stated by the appliance manufacturer.

Minor Electrical Installation Works Certificate (MEIWC)

Unit 333Certification and notification for heating control work

The BS 7671 model form issued for an addition or alteration to an existing circuit that does not extend to a new circuit or a consumer unit change. One is issued for each circuit altered.

MIS 3005

Unit 335Law, standards and schemes: what MCS is and is not

The MCS installation standard for heat pump systems, covering supply, design, installation, set to work, commissioning and handover.

misuse

Unit 331The Water Regulations: origin, enforcement and the five harms

One of the five harms: water used for a purpose it was not supplied for, such as a domestic supply used for an unauthorised industrial process.

Mixed temperature system

Unit 333Underfloor with radiators: mixed temperature systems and zones

A heating system serving emitters that need different flow temperatures, such as radiators at about 70 °C and an underfloor circuit at 40 to 45 °C.

mixer tap

Unit 331Backflow protection levels: point of use, zone and whole site

A tap or shower valve fed by both hot and cold water that blends them to a single outlet. Where the waterways join before the outlet, hot (fluid category 2) can cross into the cold supply, so each feed carries a single check valve unless the fitting is bi-flow.

Monobloc

Unit 335Installing to the standards: pipework, penetrations and insulation

A heat pump with the whole refrigeration circuit in the outdoor unit, so system water is carried outdoors between the unit and the building.

Monobloc heat pump

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

An air source heat pump in which the whole refrigerant circuit is contained, sealed and factory-charged inside the outdoor unit. Only insulated flow and return water pipes enter the building.

Monovalent system

Unit 335Monovalent, bivalent systems, buffers and system volume

A system in which one kind of heat source covers the whole heating demand at all times, even where two machines of that kind are used together.

Most remote outlet

Unit 331Flushing: the legal order and the BS EN 806-4 method

The draw-off furthest from the riser on a floor, opened first during flushing so the whole branch is scoured.

Motor overload switch

Unit 334WC macerators and lifting plants: the checks that find the fault

A protective switch that cuts the supply if the motor draws more current than its set value. Its setting is recorded at commissioning under BS EN 12056-4 clause 7.

motor winding

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

The coils of insulated copper wire inside a motor that produce its magnetic field. Their resistance, measured with a low resistance ohmmeter after safe isolation, shows whether a winding is shorting (a low reading) or going open (a high reading).

Motorised valve

Unit 332Three levels of safety on an unvented cylinder

An electrically operated valve in the primary circuit that opens to let heat reach the cylinder coil. It is switched by the cylinder thermostat and closed by the overheat thermostat.

Motorised zone valve (2-port)

Unit 333Motorised valves, isolation valves and the automatic bypass

An electrically operated valve that opens or shuts one circuit. S-plan uses one per circuit, driven by the room or cylinder thermostat.

Multi-storey building

Unit 331Multi-storey supply: the mains limit and the break cistern

For cold water design, a building with more than three floors, where the mains pressure may not reach every outlet.

Multi-zone system

Unit 333S-plan and S-plan plus: two-port valves and separate zones

A system in which several areas each have their own zone valve, room thermostat and time control, so each area is heated independently.

Multiple barrier principle

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Treating water in several stages, settling, filtering and then disinfecting, so no single stage has to remove everything.

Multipoint water heater

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

A gas fired instantaneous heater that supplies several outlets from one appliance, heating mains water on demand with no storage.

Munsen ring

Unit 333Pipework: clip spacing, expansion and insulation

A two-part brass ring clip screwed to a backplate or hung from tapped rod. It is used where pipes run in banks or are suspended from a ceiling.

MUPVC

Unit 334Locating a leak after a failed air test

Modified unplasticised PVC, a plastics material used for waste pipework. Like ABS and PVC-U it is damaged by the naphtha in chemical smoke.

Naphtha

Unit 334Locating a leak after a failed air test

A hydrocarbon present in chemical smoke that attacks plastics. It is the reason smoke testing is avoided on ABS, PVC-U and MUPVC pipework.

National Annex

Unit 334Interpreting the information before commissioning starts

A section added to a European Standard giving the practice used in one country. National Annex NG of BS EN 12056-2 gives the UK inspection, testing and maintenance methods.

Near miss

Unit 336Reviewing and reassessing: keeping it true

An event that did not cause injury but could easily have done so. It is investigated in the same way as an accident and triggers a review.

Negative head

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

An installation where the cistern is below the pump or the shower head is above the cistern, so water will not flow on its own and the pump needs a pressure vessel or transducer to start it.

Negative head pump

Unit 332Shower pumps, accumulators and shock arrestors

A shower pump designed to start and run where there is little or no head of water above it, sensing the drop in pressure rather than the flow.

Neon screwdriver

Unit 333Proving dead: the indicator, the proving unit and three readings

A screwdriver with a neon lamp in the handle. It relies on current flowing through the user, gives no reliable indication of absence of voltage, and must never be used to prove dead.

Net volume

Unit 332Recovery rate, reheat time and usable volume

The total volume a storage vessel holds, as marked on the label. Only part of it comes out hot enough to use.

Networked radiator control

Unit 333Zoning: how many zones, and what each one controls

An individual radiator control communicating with a central controller, which can be used in every room on a circuit instead of a room thermostat plus TRVs.

Neutral point

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

The position at which the cold feed and vent connect to the system, where system pressure stays the same whether the pump runs or not.

Neutraliser

Unit 333Cleansers, neutralisers, inhibitors and the in-line filter

An additive used to pacify an acid-based descaling cleanser before the system water is discharged, so the effluent is not harmful to the drain or the environment.

Neutralising agent

Unit 331Chlorine disinfection: the figures, the people and the samples

An approved chemical added to spent chlorinated water to remove the chlorine before discharge, where the sewerage undertaker requires it.

New-build installation contract work

Unit 336Programmes for contract work: new build and maintenance

Installation work carried out as part of the construction of a new building, programmed inside the main contractor's overall site programme.

Night setback

Unit 333Weather compensation, optimum start and home automation

Holding a reduced room temperature overnight or during unoccupied periods instead of switching the heating off, which limits condensation risk and speeds recovery.

No connection zone

Unit 334Joining branches to the stack: cross-flow and the no connection zone

The shaded area on a discharge stack opposite a branch connection, given in BS EN 12056-2, inside which no other branch centre line may be placed.

Nominal diameter (DN)

Unit 334Sizing a discharge stack: a worked example

The size designation used for a pipe in the European standards. It is a reference number, close to but not always identical to the actual internal or external diameter.

Nominated subcontractor

Unit 336The chain of command: who can give you an instruction

A subcontractor named by the architect in the original contract, who must then be used with the client's permission.

Non-concussive tap

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A self-closing tap with a spring-loaded plunger that runs for a set time, up to about 20 seconds, then closes itself. Named for cushioning the closure against hammer.

Non-condensable gases

Unit 335Air source heat pumps: frost, defrost and fault finding

Air or other gases that will not condense at circuit conditions. They raise pressures, reduce performance and usually indicate poor evacuation or a leak.

Non-conformity

Unit 336Certificates, records and handover: what you leave behind

A finding at audit or inspection that something required has not been done or not been recorded.

Non-contact voltage detector

Unit 333Proving dead: the indicator, the proving unit and three readings

A single-pole detector that senses a live conductor without touching it. GS38 permits its use for identifying live equipment only, never for proving dead.

non-mechanical backflow prevention

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

Backflow protection that works by an arrangement rather than a moving device: the air gaps (types AA, AB, AD, AG, AUK1, AUK2, AUK3) and the permanently vented pipe interrupter (type DC). The Regulations and BS 8558 prefer it to mechanical devices wherever practicable.

Non-potable water

Unit 335Rainwater harvesting: collection, filtration and storage

Any water other than potable water, sometimes called unwholesome water. Harvested rainwater and treated greywater are non-potable.

Non-return valve (NRV)

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A valve that lets water flow one way only, fitted on a pump delivery so the column cannot run back through the pump.

Non-self-resetting energy cut-out

Unit 332Three levels of safety on an unvented cylinder

A safety device that disconnects the supply of heat if the store overheats and stays off until it is reset by hand. Also called the overheat thermostat, thermal cut-out or high limit thermostat.

non-verifiable check valve (EB, ED)

Unit 331System history: commissioning records, logbooks and inspection frequencies

A single (EB) or double (ED) check valve without a test point. Because it cannot be tested in place, BS EN 806-5 has it replaced every 10 years.

non-wholesome water

Unit 331Approved contractors: certificates of compliance and other notices

Water that does not meet drinking water standards: rainwater, greywater, recycled water or water from an untested private source. It may be used for WC flushing and irrigation, but its pipes must be clearly identified and never cross-connected with the wholesome supply.

Normal operating pressure

Unit 331Direct, indirect and boosted systems: extra checks and first fill

The pressure a system runs at in service: mains pressure, cistern head or pump working pressure. The initial fill is made at this pressure, not the test pressure.

Not drinking water label

Unit 331Identifying non-wholesome pipework and testing for cross connections

The label, or the equivalent prohibition sign from BS EN 806-2, fixed at every outlet on a non-wholesome supply in premises other than a house. On a site where most outlets are non-potable the few potable ones may be marked instead, as long as one convention is used throughout.

Notch

Unit 334Sanitary appliances: how many, how much space, which type

A cut in the top or bottom edge of a joist to let pipework pass. Approved Document A limits its depth to one eighth of the joist depth.

notice

Unit 331Regulation 5 notification: the list and the ten working days

The written information a person proposing notifiable work must give the water undertaker before starting: their name and address, a description of the work, the location and use of the premises, and in most cases a plan of the premises and a diagram of the pipework. It is normally given on the undertaker's notification form.

Notice of completion of commissioning

Unit 332Handover: the file, the demonstration and the notices

The notice given to the building control body confirming that commissioning has been carried out to an approved procedure. It is due within 5 days under a building notice, or 30 days for scheme-registered work.

Notifiable building work

Unit 332Handover: the file, the demonstration and the notices

Work that must be notified to a building control body. Installing an unvented hot water system is notifiable, in advance unless the installer is scheme-registered.

Notifiable fitting

Unit 331Multi-storey supply: the mains limit and the break cistern

Work that must be notified to the water undertaker before it starts under Regulation 5, such as a pump drawing more than 12 litres per minute from a supply pipe.

notifiable work

Unit 331Regulation 5 notification: the list and the ten working days

Work that the law says must be reported to an authority before it starts: to the water undertaker under Regulation 5 of the Water Fittings Regulations for the operations in its table, and to the building control body under the Building Regulations for building work. Doing notifiable work without notice and consent is an offence.

Nulling

Unit 333Polarity and earth continuity: what each test proves

Setting a low-resistance ohmmeter to ignore the resistance of its own test leads, so the reading is of the conductor alone.

Occupancy

Unit 332Choosing a hot water system: people, building and appliances

The number of people living in a dwelling. It is the main driver of hot water demand and the basis of most storage sizing figures.

Occupancy pattern

Unit 333Where a heating design starts: the customer's brief

When and for how long a building is occupied, and by how many people. It affects control choices, the intermittent heating allowance and the hot water load.

Occupied area

Unit 333Underfloor heating: floor temperatures, output and comfort

The part of a heated floor where people normally stand or walk. Its surface temperature is limited to 29 °C at a room temperature of 20 °C.

Occupied property

Unit 336Programmes for private work: installations and service jobs

A property in use by its occupants while the work is carried out, which limits working hours, access and the services that can be taken out of use.

Off-peak pressure

Unit 331Performance tests: measuring flow and pressure at every outlet

The higher static pressure in the main at night when demand falls; a split float-valve washer lets by under it.

Offset

Unit 334Discharge stacks: sizes, the base, offsets and stub stacks

A change of direction in a discharge stack. In the wet part of the stack it causes suction below and positive pressure above, so it is avoided where possible.

Ogee gutter

Unit 334Terraces, outlet positions and keeping a rainwater system working

An ornamental gutter profile with an S-shaped front face, common on Victorian buildings and often required on period terraces.

One-pipe system

Unit 333One-pipe, two-pipe and reverse return layouts

A heating layout in which a single ring of pipe leaves the boiler and returns to it, with both tails of every radiator connected to that ring. Water cools progressively round the loop.

Open circuit

Unit 333Testing the finished controls: earth continuity and polarity

A break in a conductor or winding, so no current can flow. An instrument shows it as infinity or OL.

Open loop system

Unit 335Ground source heat pumps: the four collector types

A system that abstracts water from a well, borehole or watercourse, takes heat from it through a heat exchanger, and returns or discharges it. It normally needs an abstraction licence.

Open safety vent

Unit 333Expansion: sizing the vessel and the feed and expansion cistern

The open pipe from an open vented system that rises above the feed and expansion cistern and turns over it, providing a permanent path to atmosphere. It rises at least 450 mm above the water level.

Open vent

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

The safety pipe that rises from the system and discharges over the feed and expansion cistern. It gives steam and expanding water an unrestricted path to atmosphere and may never contain a valve.

Open vent pipe

Unit 332Vented hot water storage: cold feed, vent and layout

The pipe from the top of the hot water storage vessel or draw-off to a point above and over the cistern water level. It keeps the system at atmospheric pressure and acts as a safety device.

Open ventilation

Unit 334Air admittance valves: checks when foul air gets in

Ventilation of a drainage system by a pipe open to the outside air, which can both admit and release air. It is what relieves positive pressure in the below-ground system.

Open-loop system

Unit 335Ground collectors: trenches, slinkies, boreholes and ponds

A water source system that abstracts water from a borehole or watercourse, takes heat from it through a heat exchanger, and then returns or discharges it, rather than circulating brine in a sealed loop.

Operating instructions

Unit 334Handing over: the documents and the demonstration

The manufacturer's document telling the user how to run an appliance, what it will accept, how to isolate it and what maintenance it needs.

operation and maintenance instructions (O&M manual)

Unit 331Sources of fault information: the end user and the manufacturer

The document set that explains how a component or system is operated, serviced and fault-found. It holds the fault-finding chart and parts list, and at handover it forms the operation and maintenance manual given to the user.

Operation and maintenance manual (O&M manual)

Unit 331Handover: the file and the demonstration

The file of manufacturers' installation, operating and servicing instructions for every item of equipment, which BS EN 806-5 clause 5 requires to be available, retained and followed.

Operational checks

Unit 333Operational checks: the vessel, the controls and the electrical work

The checks required by BS EN 14336 clause 5.8 that every component of the system works correctly, made before the system is set to work and balanced.

Operative

Unit 336Craft levels and allocating work: who supervises whom

A person carrying out the work on site. Craft operatives are skilled tradespeople; building operatives carry out labouring and specialist support tasks.

Operator

Unit 334Telling the client, isolating safely and decommissioning

The person or organisation responsible for running a plant, such as a managing agent or facilities manager. Faults that cannot be corrected are notified to them in writing.

Optimum start

Unit 333Weather compensation, optimum start and home automation

A control function that calculates the heat-up time needed and starts the system at the latest moment that still reaches the setpoint at the start of occupancy.

Order of operations

Unit 336Work programmes: what they are and what they show

The sequence in which activities must be carried out, because each one depends on those before it.

Orientation (azimuth)

Unit 335Orientation, tilt and shading: judging a site for solar

The compass direction a collector faces. Due south gives the most annual solar energy in the UK.

over-rim bidet

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

A bidet filled by taps discharging over its rim, like a basin, so a tap gap protects it and it is treated as fluid category 3. A bidet with an ascending spray or submerged inlet is fluid category 5 and is notifiable.

Over-seven-day injury

Unit 336Permits, reporting and the people your work affects

An injury that leaves a worker unable to do their normal duties for more than seven consecutive days, not counting the day of the accident. It is reportable to the HSE within 15 days.

Overall area

Unit 335Collector performance: aperture area and the efficiency curve

The full outside area of a solar collector, including its frame. It determines the roof space required and the wind loading, but overstates output if used in the energy calculation.

Overcurrent protection

Unit 333Checking the existing installation before you connect

Protection of a circuit against currents higher than the conductor can safely carry, provided by a fuse or circuit breaker of the correct rating.

Overcurrent protective device

Unit 335The electrical supply and the DNO: settle it at survey

The fuse or circuit breaker that disconnects a circuit when the current exceeds a safe value for the cable.

Overflow pipe

Unit 331Large cisterns: warning pipes, overflows and inlet valves

A pipe fitted above the warning pipe on cisterns over 1,000 litres to carry away the full inlet flow if the float valve fails.

Overflowing level

Unit 334Performance testing a branch pipe for self-siphonage

The level at which an appliance being filled would start to overflow. Performance tests fill to this level so the discharge is the worst case.

Overheads

Unit 336Cost and quantities: estimator and quantity surveyor

The indirect costs of running a job or a business, such as site offices and site and administration salaries, added as a percentage when a job is priced.

P trap

Unit 334Branch discharge pipes: diameter, length and gradient

A trap whose outlet leaves horizontally, or nearly so, suiting a branch that runs to a stack on the same level.

pacing out

Unit 331Reading drawings: elevations, sections, specifications and site surveys

Estimating a distance by counting strides of a known length. A rough check only, never a design measurement.

Package (unvented)

Unit 332Units, packages, approval and commissioning records

A proprietary unvented hot water storage system supplied with the safety devices factory fitted to the vessel and the remaining controls loose, for the installer to fit.

Package label

Unit 335SCOP, SPF and system efficiency: the honest figures

An energy label produced for a heating system as installed, reflecting the combined performance of the heat pump and its controls rather than the appliance alone.

Packaged booster set

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A booster set assembled and wired at the factory on one skid, with pumps, manifolds, control panel and accumulator, needing only final connections on site.

Packaged treatment works

Unit 334Cesspools and septic tanks: how they work and what they need

A prefabricated plant that treats effluent to a higher standard than a septic tank, normally allowing direct discharge to a watercourse.

Panel radiator

Unit 333Radiators: fixing height, brackets and valve connections

A pressed steel heat emitter, usually with convector fins welded to the back. It gives most of its output by convection and the rest by radiation.

Parallel grid absorber

Unit 335Collectors: flat plate, evacuated tube and unglazed

An absorber in which fluid flows through parallel tubes between two headers, giving balanced flow across the plate. Also called a harp.

Parallel path

Unit 333Polarity and earth continuity: what each test proves

An alternative route for the test current, such as bonded pipework, which lowers a continuity reading and can hide a broken conductor. Avoided by disconnecting one end of the conductor under test.

Parasitic circulation

Unit 332Vented hot water storage: cold feed, vent and layout

Unwanted gravity circulation of hot water up the vent or draw-off pipe, which drains heat from the store. Also called one pipe circulation.

Part G

Unit 331Building Regulations Part G: notices and competent person self-certification

The section of the Building Regulations dealing with sanitation, hot water safety and water efficiency. Requirement G1 demands wholesome water for drinking, food preparation and washing and water of suitable quality for WC flushing; G2 and Regulation 17K limit new dwellings to 125 litres of water per person per day.

Part L

Unit 333Floor insulation and the layers before the screed

The part of the Building Regulations for England and Wales covering conservation of fuel and power. Northern Ireland uses technical booklet F and Scotland uses section 6.

part number

Unit 331Sources of fault information: the end user and the manufacturer

The manufacturer’s reference for an individual spare part, taken from the parts list in the instructions. When ordering, quote it together with the equipment model number so that the right part for that model arrives.

Part P

Unit 333Checking the existing installation before you connect

The part of Schedule 1 to the Building Regulations covering electrical safety in dwellings. It creates the legal duty; BS 7671 gives the technical means of meeting it.

Partially separate system

Unit 334Combined, separate and partially separate drainage

A drainage system that is mainly separate but where the sewerage undertaker permits one or two rainwater connections into the foul drain.

passing (let-by)

Unit 331Booster set controls: accumulator, pressure switch and float switch

A valve that is passing lets water through when it should be shut — a check valve leaking backwards, or a stopvalve that will not close fully. A float valve that lets by overflows the cistern.

Passing valve

Unit 331Soundness testing: current standards, equipment and procedure

An isolating valve that lets water by when closed, so the gauge falls into an unfilled section as if there were a leak.

Passive system

Unit 335Solar thermal: what it delivers and how the circuit works

A solar thermal system in which the heat transfer fluid circulates by natural circulation, with no pump.

Passive trap

Unit 334Testing a range of appliances for induced siphonage

A trap belonging to an appliance that is not being used while another appliance discharges. It is the trap that loses its seal to induced siphonage.

Pasteurisation cycle

Unit 332Heat pump cylinders: coil area, store temperature and reheat

A periodic heating of the whole stored volume to 60 degrees or above to kill legionella, usually driven by a second heat source such as an immersion heater on a timer.

pathogen

Unit 331Backflow risk: the duty and the five fluid categories

A micro-organism that causes disease, such as the bacteria and viruses found in sewage and animal waste. Any fluid that may contain pathogens is fluid category 5, because a single exposure can cause infection and the organisms multiply rather than dilute.

Pattern of use

Unit 332Choosing a hot water system: people, building and appliances

When and how a household draws hot water across the day. Two homes with the same daily total can need very different systems if one takes its water in a single peak.

Payback period

Unit 335Air source heat pumps: the benefits and where they struggle

The time taken for the savings a system produces to equal the extra cost of installing it. It is shortest where the system displaces an expensive fuel such as electricity, coal or oil.

PD 855468

Unit 331Approved contractors: certificates of compliance and other notices

A published document giving UK guidance on the flushing and disinfection of water services in buildings, complementing BS EN 806-4. It covers the consents needed before disinfectant is discharged to a sewer.

peak demand

Unit 331Available pressure and flow, feed arrangements and loading units

The busiest time of day for the water supply, when the most outlets in the area are drawing and mains pressure is at its lowest. The design pressure for a mains-fed system is the minimum pressure measured at peak demand or given by the water undertaker.

Peak flow

Unit 334The stack performance test: choosing appliances from Table NG.1

The highest flow rate a system is expected to carry in normal use. Table NG.1 is based on a criterion of satisfactory service of 99 per cent of that loading.

Penalty

Unit 336Project delays and contingency planning

A sum a contract allows to be recovered when work is not completed within the agreed time without agreement to an extension.

Perched aquifer

Unit 331Private water supplies: sources and responsibilities

A pocket of ground water held above the main water table, the least reliable source because it dries up in a long dry spell.

Performance estimate

Unit 333Handover: the demonstration, the pack and the notices

The statement of expected performance given to the customer before the contract was agreed. It is the reference point against which later claims about performance are judged.

Performance test

Unit 331Performance tests: measuring flow and pressure at every outlet

The operational check that measures pressure and flow rate at every outlet against the specification (BS 8000-15 clause 4.5).

Peripheral area

Unit 333Underfloor heating: floor temperatures, output and comfort

The strip of floor next to an outside wall or window where pipes are laid closer together. Its surface may reach 35 °C and its limit output is 175 W/m².

Peripheral insulating strip

Unit 333Underfloor pipework: patterns, insulation, screed and testing

The compressible strip fixed round the perimeter of a heated screed before it is laid, allowing at least 5 mm of expansion. Also called an edge joint.

Permanent level control

Unit 334Waste water lifters and sink waste disposal units

The level sensing device in a lifting plant that triggers an alarm when the tank contents rise above the working level.

Permanent live

Unit 333Wiring centres, programmers, pump overrun and frost protection

A live conductor that remains energised whatever the controls are doing. It supplies the programmer and any boiler circuit, such as pump overrun, that must work after the switched live has gone.

Permit to work

Unit 336Site procedures: inductions, toolbox talks and safety memos

A formal written authorisation to carry out a defined higher-risk task under stated conditions, used for work such as hot works, confined spaces and work on live services.

Permitted development

Unit 335Orientation, tilt, shading and permitted development

Development allowed without a planning application, subject to conditions. Solar equipment has dimensional limits and is excluded on listed buildings.

Persistent venting

Unit 333Pumping over and persistent venting on open vented systems

The repeated need to release gas from the same emitters. It indicates aeration or corrosion in the system rather than ordinary trapped air.

Personal protective equipment (PPE)

Unit 336Control measures and the hierarchy of control

Equipment worn or held by a person to protect them against risks, such as eye protection, gloves, respirators, footwear and harnesses. It is the last resort in the hierarchy.

Persons affected

Unit 336Hazard and risk: telling the two apart

Everyone who could be harmed by a work activity: the operatives, other trades, the client and occupants, the public, and those who use or maintain the building later.

pH

Unit 331System history: commissioning records, logbooks and inspection frequencies

A scale from 0 to 14 of how acidic or alkaline water is, 7 being neutral. It affects corrosion and how well chlorine works, but it has no direct effect on flow rate and is barely changed by a softener. pH indicator strips change colour to show the value.

Photovoltaic (PV)

Unit 335Solar thermal: what it delivers and what it cannot

A separate technology that converts sunlight directly into electricity using semiconductor cells. It is frequently confused with solar thermal, which produces heat instead.

pillar tap

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

A tap with a vertical inlet that stands up from the appliance. A high-neck pillar tap raises the outlet so the AUK3 tap gap over a sink is achieved.

Pillar terminal

Unit 333Terminations and joints: making the connection last

A terminal in which the conductor is pushed into a hole in a metal pillar and clamped by a grub screw from the side. Used for the supply cable in a standard fused connection unit.

Pipe centres

Unit 333Underfloor pipework: patterns, insulation, screed and testing

The centre-to-centre spacing of the underfloor pipe runs, typically 100, 200 or 300 mm. Closer centres give more output per square metre.

pipe chart

Unit 331Accumulators on a weak main and the calculation sheet

A chart or table, published for each pipe material, that relates flow rate, pipe diameter, velocity and head loss per metre, so that any two known values give the other two. It is the reference for the tabular sizing method.

pipe clip

Unit 331Sources of fault information: the end user and the manufacturer

The bracket that fixes a pipe to a wall or joist. Pipework that is insufficiently clipped moves and knocks when a valve closes and becomes noisy at high pressure.

Pipe freezing kit

Unit 332Isolating, decommissioning, rectifying and handing back

Equipment that forms an ice plug in a pipe so a section can be worked on without draining or isolating the whole system.

Pipe interrupter (type DC)

Unit 334Urinals: flush rates, controls and pressure flushing valves

A permanently vented backflow prevention device with no moving parts, fitted at least 300 mm above the spill-over level of a WC pan or urinal served by a pressure flushing valve.

pipe section

Unit 331Pipe sizing from BS EN 806-3 tables and pump duty

A length of pipe between two junctions, numbered from the source, that carries the same flow along its whole length. Each section is sized on the loading units it carries and, for the small sizes, on its length.

Pipe shoe

Unit 334Terraces, outlet positions and keeping a rainwater system working

A curved fitting on the bottom of a downpipe that throws the discharge away from the wall onto a lower roof or paved area.

Pipe thermostat

Unit 332Secondary circulation: pump position, balancing and controls

A thermostat clamped to a pipe that senses the water temperature inside it and switches the circulating pump. Also called an aquastat.

pipe-freezing kit

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

Equipment that freezes a plug of ice inside a pipe with a refrigerant spray or an electric unit, so that a section can be opened where there is no valve, without draining the whole building.

Pipeline level switch

Unit 331Multi-storey supply: the mains limit and the break cistern

A level switch on a drinking water header that starts the pumps as the header empties.

Pipework heat loss

Unit 333Heat gains, pipework losses and what the design ignores

Heat given up by the flow and return pipes on their way to the emitters. It is useful where the pipe runs through a heated room and wasted where it runs through an unheated void.

PIR

Unit 333Floor insulation and the layers before the screed

Polyisocyanurate rigid insulation board. It has a lower thermal conductivity than EPS, so about 75 mm does the job of 110 mm of EPS.

PIR detector

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A passive infra-red movement sensor that opens a solenoid valve on a urinal supply for a short period when it senses a person.

Pitch

Unit 334Effective roof area: pitch, walls and the two accepted methods

The angle of a roof slope from the horizontal. It decides the factor applied to the plan area when the effective roof area is worked out.

plan

Unit 331Design information: manufacturer data, customer feedback and scale plans

A drawing that looks straight down on a site, building or room. Block plans, site plans, floor plans and part plans are all plans, each drawn at a scale suited to what it shows.

Plan area

Unit 334Effective roof area: pitch, walls and the two accepted methods

The area of a roof as seen from directly above, ignoring the slope. It is the starting figure for every effective area calculation.

Planned preventative maintenance

Unit 333Notifying the client, safe isolation and temporary decommissioning

Maintenance arranged in advance at set intervals to keep a system working, rather than in response to a breakdown.

Planned preventive maintenance (PPM)

Unit 336Programmes for contract work: new build and maintenance

Maintenance carried out at set intervals to prevent failure, rather than in response to it.

Planning engineer

Unit 336Who does what: responsibilities on a building services job

The person responsible for pre-contract planning and for identifying the most economic and efficient use of labour, plant and materials.

Planning permission

Unit 335Permitted development: what it means, and solar on a roof

Official permission from the local authority for a new building, an alteration or an addition to an existing building.

Plant

Unit 336Ordering plant and materials, and checking what arrives

The machinery and equipment used to carry out construction work, such as access towers, pumps, lifting gear and power tools, whether owned or hired.

Plant hire

Unit 336Building a price: a worked example

The cost of hiring machinery for the days an activity occupies, plus consumables such as blades and discs.

plant room

Unit 331Identifying non-wholesome pipework and testing for cross connections

The room in a larger building that houses the boilers, pumps, cisterns, booster sets and treatment equipment. Pipe identification matters most here, where someone years later may add a connection to the wrong pipe.

Plate heat exchanger

Unit 332Combination boilers, heat exchangers and mixing valves

A water-to-water heat exchanger built from corrugated plates carrying two separated circuits, used in a combination boiler to heat mains water instantly from the primary circuit.

Plug of water

Unit 334Why trap seals are performance tested: siphonage and compression

A slug of discharge that fills the bore of a branch pipe completely as it flows. The pressure behind it drops, which is what pulls trap seals out.

Pneumatic pressure vessel

Unit 331Booster sets: the pressure vessel and the control switches

A vessel on a booster set holding a small reservoir of water under a cushion of compressed air, which keeps the system at design pressure while the pumps are off.

Pneumatic test

Unit 331Soundness testing: current standards, equipment and procedure

Testing with compressed air or gas instead of water; not recommended because of the risk of explosion (BS 8558 clause 5.1.9.1).

Point of delivery

Unit 331Chlorine disinfection: the figures, the people and the samples

The point where the undertaker's supply becomes the customer's installation; the supplier is told if disinfectant could reach it.

Point of isolation

Unit 333Safe isolation: the seven steps in order

The device that actually disconnects the circuit being worked on, usually the protective device at the consumer unit. It is the device that gets locked off and labelled.

point of use protection

Unit 331Backflow protection levels: point of use, zone and whole site

Backflow protection at or close to an individual fitting or outlet: the tap gap over a basin, a single check valve on each feed to a mixer, a double check valve serving a garden tap. It is the primary protection every outlet must have; zone and whole site protection are added to it, not instead of it.

Polarity

Unit 333Polarity and earth continuity: what each test proves

The correct arrangement of line and neutral throughout a circuit, with every fuse and single-pole switching or protective device in the line conductor only.

Polybutylene

Unit 331Soundness testing: test pressures for metal and plastics pipework

A flexible plastics pipe material that expands under test pressure and so needs Test A or Test B rather than the metal one-hour test.

Pond loop

Unit 335Ground collectors: trenches, slinkies, boreholes and ponds

A ground heat exchanger submerged in a pond or lake. It needs a minimum water depth of 3 m and roughly 9 square metres of water surface per kW of output.

Ponding

Unit 334The water test and the gutter test: where each one applies

Water standing in a low spot in a gutter instead of running to the outlet. It shows the gutter has not been fixed to even falls.

porous hose

Unit 331Filling loops and outside taps: protecting heating and garden connections

A garden irrigation hose that weeps water along its whole length, also called a permeable or mini-irrigation hose. Because it lies in soil it is fluid category 4 in a house garden, protected by a type DB pipe interrupter in addition to the tap's double check valve, and category 5 elsewhere.

Port AB

Unit 333Y-plan and W-plan: mid-position against diverter

The common connection of a three-port valve, taking the flow from the boiler. Port A serves the heating and port B the cylinder heat exchanger.

Positive head

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

An installation where the cistern base is above the shower head and pump, so water flows on its own to lift the flow switch.

Positive pressure

Unit 334The air test requirement: 38 mm water gauge for 3 minutes

A pressure above atmospheric. The air test applies a positive pressure inside the pipework so that any leak pushes air outwards.

Powerflushing

Unit 333Cold flushing, hot flushing and the power flush

A cleaning and flushing procedure using an external pump and tank to circulate water or cleaner at increased velocity and turbulence through the whole system and each radiator in turn.

Practical completion

Unit 336Accepting finished work: snagging, records and handover

Acceptance of the works at the end of a project, at which point the building is usable and the defects period begins.

pre-charge

Unit 331Accumulators on a weak main and the calculation sheet

The air pressure put into an accumulator or expansion vessel before it is connected, so the bladder is already under pressure. It must be below the incoming water pressure or the vessel never fills; for an accumulator the usual rule is about half the supply pressure, with a pressure-reducing valve upstream to protect the bladder.

Pre-charge pressure

Unit 331Booster sets: the pressure vessel and the control switches

The air pressure in a vessel or accumulator with no water in it, set to about 90 per cent of the pump cut-in pressure.

Pre-commissioning checks

Unit 333Before commissioning: the documents, the conditions and the inspection

The inspections and tests in BS EN 14336 clause 5 that bring a system to static completion before it is set to work. They include the state of the system, water tightness, pressure test, flushing, filling and venting.

Pre-construction information

Unit 336CDM 2015: duty holders, domestic clients and induction

Information about the site and the project provided by the client to designers and contractors so that risks can be identified and planned for before work begins.

Pre-flush

Unit 333Cold flushing, hot flushing and the power flush

A flush carried out before the chemical clean where a system is heavily fouled, or with a disinfectant where microbiological fouling is suspected.

Pre-installation checklist

Unit 335The pre-installation survey: deciding whether a job can go ahead

A list of conditions confirmed before installation begins. Every item is a condition, and its output is a decision on whether work can start.

Pre-use check

Unit 336Work at height: ladders, harnesses and the definition

The check made by the person about to use access equipment, carried out every time and in addition to any formal inspection.

Precaution

Unit 336The five steps of a risk assessment

A measure decided at step three of the assessment to remove a hazard or reduce the risk from it before the work is carried out.

Premises other than a house

Unit 331Regulation 5 notification and the certificates of compliance

The Regulation 5 wording that makes extensions and alterations notifiable everywhere except in a private house.

Preparatory work

Unit 336Sequencing with other trades and site readiness

The work by other trades that must be complete before an activity can start, such as chases, screeds, openings and wall finishes.

Prescribed zone

Unit 333Checking the existing circuit: rating, condition and damage

A permitted route for a cable buried less than 50 mm deep in a wall: within 150 mm of the top of the wall or of a corner, or running vertically or horizontally to the accessory it serves.

Presetting data

Unit 333Balancing radiators to the design temperature difference

Manufacturer's tables giving the number of turns from closed a valve needs for a given flow rate at a given pressure drop, allowing a circuit to be set without measurement.

Pressure (pilot) operated valve

Unit 331Large cisterns: warning pipes, overflows and inlet valves

A large inlet valve in which a small float-operated pilot valve controls a diaphragm chamber that opens and closes the main valve.

Pressure control

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Running a private supply pump from a pressure switch or transducer so it charges an accumulator and the sink can be fed at pressure.

Pressure drop

Unit 334Applying the air test and reading the result

A fall in the manometer reading during the test period. Any steady drop means air is escaping and the system has failed the test.

Pressure filter

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A sand bed sealed in a cylinder so the supply keeps its pressure through the filter; backwashed like a rapid filter.

Pressure flushing cistern

Unit 334WC flushing: volumes, devices and overflow protection

A WC flushing device that uses the pressure of water in the supply pipe to compress air, increasing the pressure of the water available for the flush.

Pressure flushing valve

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A valve that flushes a urinal or WC direct from the supply pressure without a cistern, limited on a urinal to 1.5 litres per flush.

pressure gauge

Unit 331Available pressure and flow, feed arrangements and loading units

An instrument, usually screwed onto an outside tap, that reads the pressure in the pipe in bar or kPa. Read at a busy time of day it gives the minimum mains pressure for the design.

Pressure limiting valve

Unit 332The unvented inlet control group and its order

A coarser pressure control used on stronger stainless steel vessels, set higher than a close-control reducing valve. It is not interchangeable with a reducing valve.

Pressure loss per metre

Unit 333Flow rate and pipe size: from kilowatts to millimetres

The resistance a pipe offers to flow, in pascals per metre of run. It is read from the sizing table alongside the pipe size and used to work out the pump duty.

Pressure reducing valve (PRV)

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A valve to BS EN 1567 that gives a lower, steady downstream pressure by balancing the pressure on a diaphragm against a spring.

Pressure relief valve (PRV)

Unit 333Sealed systems: expansion vessel, filling loop and safety valve

The safety valve on a sealed system. Non-adjustable, spring loaded and pre-set to lift at a gauge pressure not exceeding 3 bar, with a manual test device and a full-bore discharge pipe.

pressure surge

Unit 331Galvanic corrosion and the seven steps to handover

A sudden rise in pressure in a pipe caused by water being stopped or started abruptly, for example refilling a drained system with the valves fully open. Refilling slowly, with the stopvalve partly open and the taps cracked open to vent, prevents it.

Pressure switch

Unit 331Booster sets: the pressure vessel and the control switches

A switch in which a diaphragm works electrical contacts at a set pressure, used to start and stop booster pumps.

Pressure transducer

Unit 331Multi-storey supply: the mains limit and the break cistern

An electronic sensor that turns pipe pressure into an electrical signal a control panel can read, so the panel can start the pumps when the pressure falls.

Pressure zone

Unit 331Multi-storey supply: the mains limit and the break cistern

A section of a tall building served by its own break cistern and pumps, so the pressure on each section stays within the limits its fittings can take.

pressure-reducing valve (PRV)

Unit 331Design information: manufacturer data, customer feedback and scale plans

A valve that lowers the pressure on its outlet side to a set value whatever the inlet pressure. Fitted where the static pressure at an outlet would exceed 500 kPa (5 bar), in the inlet group of an unvented cylinder, and upstream of an accumulator to protect its bladder.

Pressurisation unit

Unit 333Multiple boilers, low loss headers and hydraulic separation

A packaged pump and vessel assembly that fills a large sealed system and maintains its pressure automatically, used instead of a filling loop.

Primary

Unit 333Underfloor heating faults: the manifold, the loops and a hot floor

The pipework between the heat source and the manifold, carrying water at the heat source temperature before it is blended down.

Primary circuit

Unit 333Underfloor with radiators: mixed temperature systems and zones

The flow and return between the heat source and the things it serves, such as the cylinder coil and the underfloor manifold. Its heat cannot be switched off by a room control.

Primary circulation pipe

Unit 333Pipework: clip spacing, expansion and insulation

Pipework carrying water between the heat source and the emitters or the cylinder coil. Part L sets where and how it must be insulated.

Primary ventilated stack system

Unit 334Primary ventilated stacks: the branch limits that decide the layout

A layout in which appliances are closely grouped around one discharge stack and the stack, extended to atmosphere, provides all the ventilation. Formerly called the single stack system.

Primary water

Unit 332Direct, indirect and combination cylinders compared

The water circulating between the heat source and the heat exchanger. It is never drawn off at a tap, so it may be treated with inhibitor in a double feed system.

Prime cost

Unit 336Contract types: fixed cost, variable cost and cost plus

The actual cost of the labour, materials and plant used on a job, before overheads and profit are added.

priming

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

Filling a pump body and its suction pipe with water to drive out the air so that the impeller can move water. An air-locked pump is primed through its priming plug with the suction valve opened first.

Principal contractor

Unit 336CDM 2015: duty holders, domestic clients and induction

The contractor appointed to plan, manage and monitor the construction phase where there is more than one contractor. It prepares the construction phase plan, provides welfare and ensures site inductions are given.

Principal designer

Unit 336Running the job: managers, clerk of works and supervisors

The duty holder appointed to plan, manage and monitor the pre-construction phase, advising and assisting the client and team with their health and safety responsibilities.

Printed circuit board

Unit 334WC macerators: how they work and how the outlet runs

The board on which manufacturers mount the electronic components that control an appliance.

Priority flow arrangement

Unit 333Y-plan: the mid-position valve and how it differs

A design in which one circuit, usually the hot water cylinder, is served before the other, so heating is suspended while the cylinder reheats.

Private customer

Unit 336Types of client: private, contracting and internal

An individual who engages a plumbing firm directly for work on their own property, such as a homeowner or a landlord.

Private installation work

Unit 336Programmes for private work: installations and service jobs

Installation work carried out for a private customer in their own property, such as replacing a bathroom with a wet room.

private supply

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

Water from a source other than the water undertaker, such as a borehole, well or spring. Where it shares a building with the mains it is treated like any other non-wholesome fluid: entirely separate pipework and clear identification.

Private Water Supplies Regulations

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The regulations that set the quality standards for water not supplied by a water undertaker and require each supply to be risk-assessed, sampled and tested by the local authority. England had the 2009 Regulations, replaced by the 2016 Regulations; Wales has its 2010 Regulations.

Private Water Supplies Regulations 2016

Unit 331Private water supplies: sources and responsibilities

The regulations that govern private supplies in England, enforced by the local authority through risk assessment, sampling and notices.

private water supply

Unit 331Scope of the Regulations: mains supplies in, private supplies out

Any water supply not provided by a water undertaker: a borehole, well, spring, stream, river, lake or pond serving one house or a small private network. The owner or user is responsible for it, the Water Fittings Regulations do not apply to it (apart from the ban on cross-connection to a mains supply), and its quality is policed by the local authority under the Private Water Supplies Regulations.

Profit margin

Unit 336Resources: labour, materials, plant and vehicles

The proportion of the price that remains as profit once the costs of the work have been met.

Programmable room thermostat

Unit 333Programmers, thermostats and the wiring centre

A single unit that holds a time schedule and senses room temperature, providing time and temperature control together.

Programme holder

Unit 336Monitoring progress: readiness, slippage and who to tell

The person or organisation responsible for the overall work programme on a project, normally the principal or main contractor.

Programmer

Unit 332Thermostats, cut-outs, programmers and motorised valves

The time control that decides when the hot water and heating circuits call for heat. Faults include a lost or wrong time setting, failed boost functions and failed switching.

Project manager

Unit 336Running the job: managers, clerk of works and supervisors

The person responsible for the overall co-ordination and delivery of a project and for ensuring the project team works together effectively.

Projection effect

Unit 335The solar resource: irradiance, insolation and the seasons

The spreading of a fixed amount of radiation over a larger area as a surface is tilted away from the beam, reducing the energy received per square metre.

Propylene glycol

Unit 336Substances on site: data sheets, glycol and spills

A glycol used as a heat transfer fluid. It is much less toxic if swallowed than ethylene glycol, which is why it is normally specified near domestic water supplies.

Protective covering

Unit 334Handing over: the documents and the demonstration

The wrapping or tape fitted to a sanitary appliance to guard it against damage on site. It is kept in place as long as practically possible, up to handover.

Protective device

Unit 333Operational checks: the vessel, the controls and the electrical work

The fuse or circuit breaker protecting the circuit. Commissioning verifies that it is of the correct type and rating for the circuit and the appliance.

Proving unit

Unit 333Proving dead: the indicator, the proving unit and three readings

A small battery-powered source of a known voltage used to prove that a voltage indicator is working, both before and after testing a circuit dead.

Provision and Use of Work Equipment Regulations (PUWER)

Unit 336The regulations that sit under the Act

Regulations setting minimum standards for work equipment: it must be suitable, fit for purpose, maintained, guarded and used only by people who have been trained.

Provision and Use of Work Equipment Regulations 1998 (PUWER)

Unit 336Safety management on site: induction, competence and training

The regulations governing work equipment. They require equipment to be suitable, maintained and inspected, and everyone who uses it to have had adequate training.

Pump control unit

Unit 333The underfloor manifold: blending, balancing and safety

The factory-assembled module carrying the manifold circulating pump and blending valve, which mixes and circulates water to the floor circuits.

Pump curve

Unit 333Pump duty: the index circuit, head and the duty point

The manufacturer's chart of the flow a pump delivers against the head it develops, usually with one curve per speed setting.

Pump cycle

Unit 334Running the macerator: cycle, leaks, faults and handover

The run of a macerator from starting on a discharge, through shredding and pumping, to stopping when the chamber is empty. It is timed at commissioning as a baseline.

pump cycling

Unit 331Accumulators on a weak main and the calculation sheet

A booster pump switching on and off repeatedly because every small draw-off drops the pressure enough to start it. It wears the pump and the switch; an accumulator stores enough water to cover small draw-offs and stop it.

pump delivery pipe

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The pipe on the outlet side of a pump. Schedule 2 paragraph 14 names it alongside supply and distributing pipes as a pipe that must never be able to convey non-wholesome water.

Pump duty

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The flow rate and pressure a pump must deliver, found from static lift, friction losses and residual pressure.

Pump overrun

Unit 333Zone valves: two-port, mid-position and diverter

A boiler circuit that keeps the pump running after the burner has shut down so that residual heat is carried away from the heat exchanger.

Pumping over

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

A fault in which the pump forces water up the open vent and into the feed and expansion cistern, aerating the system water and causing corrosion.

Purchase order

Unit 336Ordering plant and materials, and checking what arrives

The document by which a company formally orders goods from a supplier at an agreed price and delivery date.

Purge rig

Unit 333Filling and venting underfloor circuits and ground collectors

A powered pump and tank unit connected to a filled circuit to circulate the fluid at high velocity, sweeping trapped air out of pipework that cannot be vented from a high point.

PVT collector

Unit 335Collectors: flat plate, evacuated tube and unglazed

A hybrid collector that produces both thermal energy and electricity from one panel.

Qualitative method

Unit 336Ranking the risk: likelihood times severity

Ranking a risk by placing it in a category such as low, medium or high rather than on a long numeric scale.

Quantitative approach

Unit 336Ranking the risk: likelihood times severity

Ranking a risk with a number, using scales for likelihood and consequence and multiplying them together.

quantity surveyor

Unit 331Reading drawings: elevations, sections, specifications and site surveys

The construction professional who measures and prices building work, prepares the bill of quantities from the architect's drawings and controls the cost of a project.

Quarter turn tap

Unit 332Specialist taps and outlet fittings: how they work

A tap opened fully by a quarter turn of a lever, needing a push rather than a grip and so suited to users with limited hand strength.

quotation

Unit 331Design information: manufacturer data, customer feedback and scale plans

A fixed price offered for a described piece of work; once accepted it cannot be increased without agreement. It is one of the two things, with the drawings, a client needs before work starts on a dwelling.

R1+R2

Unit 333Polarity and earth continuity: what each test proves

The combined resistance of a circuit's line conductor and its circuit protective conductor, measured with the two linked at the origin and read at the far point of the circuit.

Rainfall intensity

Unit 334Sizing the gutter, the outlet and the downpipe

The rate at which rain falls, in litres per second per square metre. It is taken from a local map or, where no data exists, from the minimum values in BS EN 12056-3 multiplied by a risk factor.

rainwater harvesting

Unit 331Approved contractors: certificates of compliance and other notices

Collecting rain from roofs, storing it and pumping it to WCs, washing machines and gardens in place of mains water. The water is not wholesome, so the pipework must be identified and kept separate from the mains, and on a mains-fed site the water supplier is notified before work starts (BS 8515).

Rainwater pipe

Unit 334Sizing the gutter, the outlet and the downpipe

The vertical pipe carrying water from a gutter outlet to a drain or gully. In domestic round systems it is 68 mm; the square section equivalent is 65 mm.

RAMS

Unit 335Refrigerant, waste and the handover pack

Risk assessment and method statement. Internal documents about how work will be carried out safely, not part of the customer's handover pack.

Range of appliances

Unit 334Testing a range of appliances for induced siphonage

Several appliances of the same kind connected in a row to one common branch discharge pipe, such as a line of basins in a washroom.

Rapid sand filter

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A physical filter of coarse silica sand, 0.5 to 1 mm, that removes turbidity, algae, iron and manganese and is cleaned by backwashing. The preferred sediment removal on a small supply.

Rapid turnover

Unit 331Multi-storey supply: the mains limit and the break cistern

Sizing a cistern so the stored water is used and replaced quickly, so it does not stagnate.

re-commissioning

Unit 331Galvanic corrosion and the seven steps to handover

Putting a repaired section back into service: refilling slowly from the service stopvalve, venting, flushing, pressure testing altered pipework at 1.5 times working pressure, disinfecting where needed, then re-checking pressures and flows against the record and inspecting for leaks.

Re-sequence

Unit 336Monitoring progress: readiness, slippage and who to tell

Changing the order or timing of activities on a programme so that the work can carry on after a delay.

Reasonably practicable

Unit 336The Health and Safety at Work Act: duties on everyone

A legal test in which the size of a risk is weighed against the time, trouble and cost of controlling it. The control must be taken unless it is grossly disproportionate to the risk.

reclaimed water

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

Water that is not wholesome but is put to use, such as harvested rainwater or treated greywater; also called recycled or non-wholesome water. BS 1710 identifies its pipes with green, black, green colour bands.

Record drawing

Unit 333Laying the underfloor pipe: centres, fixing and joints

The as-installed drawing kept in the building log book. Every repair coupling in a floor construction must be located and designated on it.

Recovery rate

Unit 332Sizing the cylinder: 45 litres per occupant and the storage formula

The rate at which a heating source can bring stored water back up to temperature, expressed either as litres per hour at a stated temperature rise or as the time to reheat the vessel.

Recovery time

Unit 333Total heat load, hot water load and the boiler size

The time allowed for a hot water cylinder to reach its storage temperature from cold. Shortening it sharply increases the kilowatts required.

reduced pressure zone valve (RPZ, type BA)

Unit 331RPZ valves and single and double check valves

A verifiable backflow preventer with two check valves, a differential relief valve between them and three test points; the middle chamber is held below supply pressure and is dumped to drain if the pressure difference falls or a check valve leaks. Rated fluid category 4 for both back pressure and back siphonage, the highest of any mechanical device. It is notifiable, needs a line strainer, servicing valves and a tundish to a type AA air gap 300 mm above the floor, and is tested annually by an accredited tester.

Reed bed

Unit 335Greywater re-use: sources, treatment and storage limits

A planted bed through which greywater infiltrates. Oxygen from the reed roots supports bacteria that break down organic matter. It needs land and expertise.

Reference room

Unit 333Programmers, thermostats and the wiring centre

The room whose thermostat acts as the main temperature control for a heating circuit, and in which no other form of system temperature control is fitted.

Reflective foil system

Unit 333Joisted floors: emission plates, foil and output figures

A joisted underfloor system where the pipe sits above a reflective foil layer instead of in a metal plate. It relies on a still layer of air below the boards.

Refractometer

Unit 333Filling and venting underfloor circuits and ground collectors

A hand instrument that measures the concentration of a mixture from how it bends light. It is used to confirm the antifreeze strength in a collector.

Refrigerant

Unit 333Fuel, efficiency and environmental impact of the choice

The working fluid of a heat pump. It evaporates at low pressure while absorbing heat from the source, is compressed to raise its temperature, and condenses to release that heat into the heating system.

Refrigeration cycle

Unit 335Heat pumps: how the refrigeration cycle moves heat

The vapour compression cycle used by a heat pump: evaporate, compress, condense, expand. It moves heat from a cold place to a warmer one using work from a compressor.

Registered operative identity card

Unit 332Commissioning records and dealing with defects

The card carried by an operative registered to work on unvented hot water systems. Its number is entered on the commissioning record and on paperwork sent to the local authority.

Regulating valve

Unit 331Balancing, mechanical controls and functional testing

A valve on a floor branch used to throttle flow during balancing so that other outlets receive their share.

Regulation 3

Unit 331Regulations 3 and 4: installer tests and user duties

The regulation that sets out the five harms (waste, misuse, undue consumption, contamination and erroneous measurement) and forbids anyone to install, alter, disconnect or use a water fitting in a way that causes or is likely to cause them. Regulation 3(3) adds that no damaged, worn or faulty fitting may be used, so it binds users as well as installers.

Regulation 4

Unit 331Regulations 3 and 4: installer tests and user duties

The regulation that sets the two quality tests for water fittings, appropriate quality and standard and suitability for the circumstances, and requires installation in a workmanlike manner. Regulation 4(2) says quality is shown by a British Standard or a regulator-approved specification; 4(5) and 4(6) define workmanlike work.

Regulation 5

Unit 331Regulation 5 notification: the list and the ten working days

The part of the Water Fittings Regulations that lists the operations for which the water undertaker must be notified before work starts: erecting a building, extending or altering a water system anywhere other than a house, a material change of use, a bath over 230 litres (to the centre line of the overflow), a bidet with an ascending spray or flexible hose, a pump drawing more than 12 litres a minute, reverse osmosis, a water treatment unit with a waste or needing regeneration, an RPZ valve or other device for fluid category 4 or 5, an automatic garden watering system, pipe laid outside a building less than 750 mm or more than 1,350 mm deep, and an automatically refilled pond or pool over 10,000 litres. The notice must give names, addresses, a description of the work and the premises, and usually a plan and pipework diagram.

Regulation 6

Unit 331Approved contractors: certificates of compliance and other notices

The regulation requiring an approved contractor, on completing work, to give a signed certificate of compliance to the person who commissioned it and, where the work was notifiable, to send a copy to the water undertaker.

regulator

Unit 331The Water Regulations: origin, enforcement and the five harms

In the Water Fittings Regulations, the Secretary of State for England and the Welsh Ministers for Wales, not Ofwat. The regulator approves specifications that count as appropriate quality, specifies the bodies that can certify approved contractors, and is the only person who can relax a Schedule 2 requirement, on an undertaker's application.

Reheat time

Unit 332Heat pump cylinders: coil area, store temperature and reheat

The time taken to bring a cylinder from cold, or from a drawn-down state, back to its storage temperature. It is set by the energy needed and the power the coil can pass.

relief port

Unit 331Backflow devices: testing check valves and maintaining the RPZ valve

The discharge opening on an RPZ valve through which the relief valve dumps water when the pressure in the middle chamber gets too close to the inlet pressure. A port that keeps dripping points to a failed upstream check valve or a ruptured diaphragm.

Replacement parts list

Unit 332Manufacturer instructions, flow charts and service history

The manufacturer's schedule of the components of an appliance that can be replaced, each with a part number to be quoted alongside the model number when ordering.

Reporting line

Unit 336Quality checks: allocating areas, inspecting and testing

The formal route through which an operative takes instructions and reports problems, normally to their own supervisor.

Reporting of Injuries, Diseases and Dangerous Occurrences Regulations (RIDDOR)

Unit 336The regulations that sit under the Act

Regulations requiring the employer to record and report certain work-related deaths, injuries, diseases and dangerous occurrences to the enforcing authority.

Reporting of Injuries, Diseases and Dangerous Occurrences Regulations 2013 (RIDDOR)

Unit 336Permits, reporting and the people your work affects

The regulations requiring specified injuries, occupational diseases and dangerous occurrences to be reported to the enforcing authority.

Requisition

Unit 336Ordering plant and materials, and checking what arrives

The internal request from site to the company for materials or plant, giving quantities, sizes and the date they are needed.

Resealing trap

Unit 334Traps, seal depths and how a trap loses its seal

A trap designed for unventilated small bore branches that restores its own water seal after siphonage. Anti-vacuum traps do a similar job by admitting air.

Residual

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

The small amount of disinfectant, such as chlorine, left in the water after treatment to go on protecting it in the pipes. UV leaves none.

Residual charge

Unit 333Servicing a heat pump: coil, defrost and the water side

Stored electrical energy remaining in components after isolation, which must be allowed to discharge for the time the manufacturer states before work begins.

Residual chlorine

Unit 331Chlorine disinfection: the figures, the people and the samples

The free chlorine left at the end of the contact time, measured at the furthest outlet; not less than 30 mg/l is a pass.

Residual current device (RCD)

Unit 333Checking the existing installation before you connect

A device that compares the current flowing out along the line conductor with that returning in the neutral and disconnects quickly if the difference shows current leaking to earth.

Residual disinfectant

Unit 335Greywater re-use: sources, treatment and storage limits

The chlorine or bromine left in the treated water after disinfection. BS 8525-2 sets limits on it for each end use.

residual head

Unit 331Accumulators on a weak main and the calculation sheet

The pressure left at the end of a pipe section after the rise and the friction losses have been taken from the available head. It must be at least what the outlet or appliance needs, or the pipe goes up a size.

Residual pressure

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The pressure still needed at the outlet after static lift and friction have been overcome, so the tap or float valve works properly.

Residual risk

Unit 336Control measures and the hierarchy of control

The risk that remains after all the chosen control measures have been applied. It must be small enough to accept and must be made known to those doing the work.

Resin anchor

Unit 336Equipment and energy: wheels, isolation and refrigerant

A fixing made by injecting a two-part resin into a drilled hole and setting a stud into it. Eye protection is required because the resin is ejected under pressure.

Responsible person

Unit 333Notifying the client, safe isolation and temporary decommissioning

The person accountable for the building or the system, such as the householder, the landlord or a site manager, who must be kept informed of isolations.

Rest bend

Unit 334Discharge stacks: sizes, the base, offsets and stub stacks

The large radius bend at the foot of a discharge stack where it turns into the drain, with a centre line radius of at least 200 mm.

Retaining ring

Unit 331Check valves, water hammer and the mini expansion vessel

A ring that holds a shower hose so the head cannot reach below the rim of the bath.

Retest

Unit 331The commissioning record and the defects that go on it

Repeating a test after a defect has been corrected; nothing is handed over until the retest passes.

Retrofit

Unit 335The pre-installation survey: deciding whether a job can go ahead

Installing a system into an existing building. Retrofit work is harder than new build because the building, the drainage and the occupants are already there.

Return period

Unit 334Combined, separate and partially separate drainage

The average interval between storms of a given severity, used to set how heavy a rainfall a system is designed for. A one in ten year return period means a storm of that size is expected on average once a decade.

Return temperature limiter

Unit 333Underfloor with radiators: mixed temperature systems and zones

A self-acting control on a single-zone underfloor circuit that throttles flow when the return water is too hot, holding the floor temperature down without room-by-room control.

Reverse osmosis (RO)

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Treatment that forces water through a semi-permeable membrane to remove salts, nitrates and pesticides, wasting about 3 litres per litre made. Notifiable under Regulation 5.

Reverse return

Unit 333One-pipe, two-pipe and reverse return layouts

A two-pipe variation in which the return runs away from the boiler alongside the flow before looping back. Total circuit lengths are almost equal, so the system is close to self-balancing.

Reversing valve

Unit 335Air source heat pumps: frost, defrost and fault finding

A valve that reverses the direction of refrigerant flow so the roles of the evaporator and condenser swap. It is used for defrosting and, on reversible units, for cooling.

Review

Unit 336Reviewing and reassessing: keeping it true

The planned or triggered re-examination of a risk assessment to check that it still describes the work, the place and the people, and to update it where it does not.

Right to be accompanied

Unit 336Dealing with poor work: informal action and the formal procedure

An employee's right to be accompanied at a formal disciplinary or capability meeting, normally by a colleague or trade union representative.

Rigid pipework

Unit 331Soundness testing: test pressures for metal and plastics pipework

Metal pipework such as copper, stainless steel and low carbon steel that does not stretch appreciably under pressure, so any fall in the gauge means a leak.

Ring final circuit

Unit 335The electrical supply and the DNO: settle it at survey

A final circuit wired as a ring serving socket outlets, protected by a 30 A or 32 A device under BS 7671.

Ring test

Unit 336Equipment and energy: wheels, isolation and refrigerant

A pre-use check on an abrasive wheel: the wheel is tapped with something non-metallic and listened to. A sound wheel rings clearly and a cracked one sounds dull.

Rising main

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

The supply pipe that rises through a building to feed a storage cistern or high-level outlets.

Risk

Unit 336Hazard and risk: telling the two apart

The chance that somebody could be harmed by a hazard, together with an indication of how serious that harm could be.

risk assessment

Unit 331Scope of the Regulations: mains supplies in, private supplies out

A written review of what could go wrong, how likely it is and how serious it would be. Every private water supply must have one covering the source, storage, treatment and premises, and Approved Document G requires one before an alternative (non-mains) water source is used in a dwelling.

Risk assessment and method statement (RAMS)

Unit 336Method statements: what they are and contain

The pair of documents normally issued together for a job: the assessment identifying the hazards and controls, and the statement setting out the safe sequence of work.

Risk assessment form

Unit 336Writing it down: forms, formats and who signs

The standard document a company uses to record an assessment, with columns for the hazards, the harm, the people at risk, existing controls, the rating and the further action.

Risk calculation formula

Unit 336Ranking the risk: likelihood times severity

A method of ranking risk by multiplying likelihood by consequence to give a number that quantifies the level of risk for a particular job.

Risk factor

Unit 336Ranking the risk: likelihood times severity

The number produced by multiplying likelihood by consequence, used to place the risk in a band that determines the action required.

Rodding point

Unit 334Fire stopping, access and notification

An access fitting on discharge pipework or a stack that allows rods to be passed into the pipe to clear a blockage.

Room thermostat

Unit 333Programmers, thermostats and the wiring centre

A control that senses the air temperature of one room and calls for heat. Mounted about 1.5 m above the floor away from sunlight, draughts and other heat sources.

Root cause

Unit 333Gathering information from the end user before you test

The underlying reason a fault occurred, as opposed to the part that failed. Curing only the failed part leaves the fault to return.

RPZ valve (reduced pressure zone valve)

Unit 331Regulation 5 notification: the list and the ten working days

A mechanical backflow prevention device with two check valves and a relief valve between them that opens to drain if the pressure in the middle zone rises towards the inlet pressure, so backflow can never reach the supply. It is the highest mechanical protection, used against fluid category 4, must be tested annually by an approved tester, and is notifiable under item 4(g).

run-off

Unit 331Design information: the Regulations, notification and BS EN 806

Water drawn from an outlet and sent straight to drain, such as a tap left running or water run off while waiting for hot to arrive. Limiting it, for example with flow regulators or self-closing taps, deals with the undue consumption part of Regulation 3.

Running cost

Unit 335Comparing the technologies: carbon, cost and customer fit

The ongoing cost of fuel, electricity and maintenance once a system is installed, as distinct from the capital cost of installing it. Micro-renewable systems trade a high capital cost for a low running cost.

Running dry

Unit 333Filling the system before the controls are proved

Operating a pump with no water passing through it, so the bearings and seal lose their lubrication and cooling and are damaged.

Running outlet

Unit 334Terraces, outlet positions and keeping a rainwater system working

An outlet fitted part way along a gutter run, receiving water from both directions. It can drain almost twice the area of an outlet at a stop end.

Runoff coefficient

Unit 334Sizing the gutter, the outlet and the downpipe

A factor in the flow equation allowing for water that does not reach the gutter. It is taken as 1.0 unless national or local practice states otherwise.

S-plan

Unit 333S-plan and S-plan plus: two-port valves and separate zones

A fully pumped heating system with a separate two-port motorised zone valve on the hot water primary and on the heating circuit, each opened by its own thermostat.

S-plan plus

Unit 333S-plan and S-plan plus: two-port valves and separate zones

An S-plan with an additional two-port zone valve, so the space heating is divided into two independently controlled zones as well as the hot water.

Sacrificial anode

Unit 332Composite valves, vacuum relief and anti-legionella valves

A rod of a more reactive metal fitted inside a storage vessel. It corrodes in preference to the vessel, protecting it.

safe isolation

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The procedure for making electrical equipment safe to work on: switch off, lock off the isolator, prove the circuit dead with a voltage indicator that has itself been tested, and label it. Every electrical test on a pump or panel follows it.

Safe system of work

Unit 336Method statements: what they are and contain

A formal procedure resulting from an assessment of a task, which identifies the hazards and defines the method and controls to be used so that the work is done safely.

Safety data sheet

Unit 331Chlorine disinfection: the figures, the people and the samples

The manufacturer's sheet for a chemical that states its hazards and the PPE required to handle it.

Safety device

Unit 332Three levels of safety on an unvented cylinder

A device that protects the user and acts only when the functional controls have failed. On an unvented system the two Approved Document G requires are the non-self-resetting thermal cut-out and the temperature relief valve. The expansion relief valve does a safety job against pressure, though it is listed with the functional controls.

Safety harness

Unit 336Work at height: ladders, harnesses and the definition

A body harness attached to an anchor by a lanyard, used as a last resort to restrain a person from a fall zone or to arrest a fall. Used only by trained people and inspected before and after every use.

Safety management system

Unit 336Safety management on site: induction, competence and training

The set of arrangements, procedures, records and checks a business uses to manage health and safety, and to show that it has done so.

Safety memo

Unit 336Site procedures: inductions, toolbox talks and safety memos

A short written notice issued to everyone affected, recording a safety message such as a newly found hazard or a change to site arrangements.

Safety valve

Unit 333The safety valve and the pressure gauge

The spring-loaded valve that opens automatically if the system pressure exceeds its setting, releasing water safely. On domestic sealed systems it is set at not more than 3 bar.

Sanitary appliance

Unit 332Choosing a hot water system: people, building and appliances

A fitting that takes a water supply and discharges to drainage, such as a bath, shower, washbasin, sink or WC. The number and type of these sets the demand on a hot water system.

Sanitary convenience

Unit 334Occupancy, provision and the information a design starts from

In the Building Regulations, a closet or a urinal. Every sanitary convenience must have an associated hand washing facility.

Sanitary pipework

Unit 334Sanitary pipework: the rules and the standard sizes

The above ground pipework that carries discharges from sanitary appliances to the drain. It covers traps, branch discharge pipes, stacks and ventilating pipes.

Scalding

Unit 332Design temperatures: storage, flow, return and outlet

A burn caused by hot water or steam. Water at 60 degrees C can cause a partial thickness burn in about five seconds, which is why outlet temperatures are limited.

Scale

Unit 332Scale, blockages, airlocks and leaks

Hard deposit, mainly calcium carbonate, that forms out of hard water on the hottest surfaces of a system. It insulates heating surfaces and narrows pipe bores.

scale drawing

Unit 331Design information: manufacturer data, customer feedback and scale plans

A drawing in which every length on paper is a fixed fraction of the real length, so distances can be measured off it: at 1:50, 10 mm on paper is 500 mm in the building; at 1:100 it is 1 m; at 1:500 it is 5 m. A not-to-scale sketch shows what goes where but cannot be measured.

scale rule

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A ruler with several scales marked along its edges, such as 1:50 and 1:100, so a real length can be read directly off a scale drawing. Pick the edge that matches the drawing's scale; reading the wrong edge is the commonest mistake.

Schedule 1

Unit 331Backflow risk: the duty and the five fluid categories

The part of the Water Supply (Water Fittings) Regulations 1999 that defines the five fluid categories, from category 1 (wholesome water) to category 5 (serious health hazard).

Schedule 2

Unit 331The Water Regulations: origin, enforcement and the five harms

The part of the Water Fittings Regulations that holds the technical requirements, in numbered paragraphs: materials and substances (2 to 7), design and installation (8 to 13), backflow prevention (14 and 15), cisterns (16), WCs and urinals (25) and water economy (29), among others. Being part of the Regulations it is law, and where the guidance and Schedule 2 differ, Schedule 2 governs.

Schedule 2 paragraph 10

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The requirement that every supply or distributing pipe to separate premises has a stopvalve that shuts off that supply without shutting off any other premises, and that every occupier of a shared pipe has access to a stopvalve.

Schedule 2 paragraph 11

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The requirement that water systems can be drained down, with enough servicing valves and drain taps to minimise the water discharged when fittings are maintained or replaced, and enough stopvalves to isolate parts of the pipework.

Schedule 2 paragraph 12

Unit 331Galvanic corrosion and the seven steps to handover

The Water Regulations requirement that a water system withstands an internal pressure of not less than 1.5 times the maximum pressure it is designed to work at, together with the descriptions of the tests that satisfy it.

Schedule 2 paragraph 13

Unit 331Flushing: the legal order and the BS EN 806-4 method

The paragraph of the Water Regulations requiring every water system to be tested, flushed and where necessary disinfected before first use.

Schedule 2 paragraph 14

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

The rule that any water fitting carrying rainwater, recycled water or any fluid that is not wholesome must be clearly identified so it cannot be mistaken for a supply or distributing pipe, and that no supply, distributing or pump delivery pipe may convey, or be connected so that it can convey, such a fluid, unless a backflow device meeting paragraph 15 is fitted.

Schedule 2 paragraph 16

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

The requirement for a servicing valve on the inlet of every storage or flushing cistern and on the outlet of every storage cistern.

Schedule 2 paragraph 24

Unit 331Filling loops and outside taps: protecting heating and garden connections

The paragraph of the Water Fittings Regulations that forbids a permanent connection between a primary heating circuit and the supply pipe unless an approved backflow prevention device is fitted.

Schedule 2 paragraph 25

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

The paragraph of the Water Fittings Regulations on WC and urinal flushing. Paragraph 25(1)(b) bans a pressure flushing valve in a house or where 1.2 litres per second is not available, and 25(1)(c) requires the type DC interrupter not less than 300 mm above the spill-over level.

Schedule 2 paragraph 3

Unit 331Galvanic corrosion and the seven steps to handover

The Water Regulations requirement that every water fitting is of an appropriate quality and standard, suitable for the water and conditions it meets, and immune to or protected from corrosion by galvanic action.

Schedule 2B

Unit 331Building Regulations Part G: notices and competent person self-certification

The list in the Building Regulations of minor work that need not be notified to building control at all: replacing part of, or adding a control to, an existing cold water supply, or replacing a WC, basin, sink, bath or shower with one that uses no more water, provided no underground drainage or health-affecting work is involved. The requirements still apply; only the need to notify is removed.

Schedule of inspections

Unit 333Certification and notification for heating control work

The list of inspected items issued alongside an Electrical Installation Certificate or a condition report. It does not form part of a minor works certificate.

Schedule of rates

Unit 336Pricing methods: take-off, bills of quantities and rates

A list of agreed unit prices for defined operations, used where the type of work is known but the quantity is not. Work is measured on completion and paid at those rates.

Schedule of test results

Unit 333Testing the finished controls: earth continuity and polarity

The record of the measured values from inspection and testing: continuity, insulation resistance, polarity, earth fault loop impedance and RCD results, issued with the certificate.

schematic

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A line drawing of the pipework itself, showing every pipe, junction, valve and appliance in order but usually not to scale. It is the drawing used to explain how a system works and, with its junctions numbered, to lay out a pipe sizing calculation.

Schematic drawing

Unit 332Drawings, manufacturer instructions and the customer brief

A drawing that shows how a system connects and in what order, without representing true position, scale or route.

Schrader valve

Unit 331Borehole pumps: packaged sets, controls and the accumulator

The tyre-type air valve on an accumulator or expansion vessel through which the air charge is checked and topped up.

Scope of work

Unit 336Variation orders: pricing a change the client asks for

What the contract requires the team to do, and the constraints it must work within. A variation changes the scope.

Screed

Unit 333Underfloor pipework: patterns, insulation, screed and testing

The layer of cement, calcium sulphate or asphalt laid over the underfloor pipes, forming the heat-conducting mass and the load-bearing surface.

Scum

Unit 334Cesspools and septic tanks: how they work and what they need

The layer of grease and light material that floats on the surface of a septic tank and must not be disturbed by the inlet or outlet.

sealed heating system

Unit 331Filling loops and outside taps: protecting heating and garden connections

A heating circuit that is closed to the atmosphere and pressurised, with an expansion vessel instead of a feed and expansion cistern. Its connection to the supply pipe is a backflow risk: a temporary filling loop through a double check valve in a house, or a permanent connection through a type CA (category 3) or type BA (category 4) device.

Sealed primary circuit

Unit 332Unvented hot water: mains pressure and the overheating hazard

A heating circuit with no feed and expansion cistern or vent, filled through a filling loop and using an expansion vessel. It is separate from whether the hot water is vented or unvented.

Sealed system

Unit 333Sealed systems: expansion vessel, filling loop and safety valve

A heating system with no feed and expansion cistern, filled from the mains through a filling loop, with expansion taken up in a diaphragm expansion vessel and protected by a pressure relief valve.

Seasonal coefficient of performance (SCoP)

Unit 335CoP and lift: why flow temperature decides efficiency

The annual quantity of heat delivered divided by the annual electrical energy consumed. It reflects real performance across a heating season.

Seasonal performance factor (SPF)

Unit 332Efficiency, carbon and cost: what the heat source decides

The average efficiency of a heat pump across a whole year, taking in all its operating conditions. Running frequent high temperature hot water cycles pulls the SPF down.

Second fix

Unit 333Running the cables and wiring the control system

The stage when accessories and equipment are fitted and cables are terminated, after the building finishes are complete.

Secondary circulation

Unit 332Secondary circulation: pump position, balancing and controls

A pumped loop that returns hot water from the far end of the distribution pipework to the storage vessel, keeping the pipework hot and removing the dead leg.

Secondary flow

Unit 332Secondary circulation: pump position, balancing and controls

The hot water draw-off pipe carrying water out from the storage vessel to the outlets on a circulating system.

Secondary return

Unit 332Secondary circulation: pump position, balancing and controls

The pipe carrying circulated hot water back from the far end of the distribution system into the storage vessel.

Secondary ventilated stack system

Unit 334Ventilated branches and secondary ventilated stack systems

A layout with closely grouped appliances in which a separate ventilating stack is cross-connected to the discharge stack to control pressure within the stack.

Secondary water

Unit 332Direct, indirect and combination cylinders compared

The stored water in the cylinder that is drawn off at the hot taps. It must remain wholesome, so nothing may be added to it.

section drawing

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A drawing that cuts vertically through a building to show what is inside: floor-to-floor heights, the loft, the thickness of floors and the position of a cistern. It gives the vertical rises a floor plan cannot.

Section testing

Unit 334Applying the air test and reading the result

Testing a completed part of an installation on its own, rather than the whole system, because of its size or because that part is about to be enclosed.

Sectional cistern

Unit 331Linked and sectional cisterns in the plant room

A large cistern bolted together on site from 1 square metre GRP or protected steel panels, so it can be built to any capacity and to fit the space.

Sedentary

Unit 333Where a heating design starts: the customer's brief

Seated and inactive. A sedentary occupant gives off less heat than an active one, so activity level affects the heat gains allowed for in a design.

Seldom-used outlet

Unit 331After handover: signing off and the routine user checks

A tap or draw-off that is rarely run, flushed weekly under BS EN 806-5 clause 6 so water does not stand in its branch.

Selective surface

Unit 335Collectors: flat plate, evacuated tube and unglazed

An absorber coating that decreases radiative emission from the plate while keeping a high absorptance for solar radiation, so the plate holds the heat it gains.

Self siphonage

Unit 334When a branch is too long: ventilating pipes and air admittance valves

Loss of a trap seal caused by the appliance's own discharge filling the branch pipe and drawing a partial vacuum behind the moving water.

Self-assembled set

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A booster set built on site from separately bought pumps, valves, switches, vessel and controls, for which the installer matches and sets the parts.

self-certification

Unit 331Building Regulations Part G: notices and competent person self-certification

Certifying your own work as compliant instead of having it inspected. Under the Water Fittings Regulations an approved contractor does this with a certificate of compliance; under the Building Regulations a competent person scheme member does it under Schedule 2A.

Self-cleansing

Unit 334Primary ventilated stacks: the branch limits that decide the layout

A pipe laid so that the flow through it scours the bore and carries solids away, rather than letting them settle.

Self-cleansing velocity

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

The flow speed a waste pipe needs to carry solids away; the small discharge from a self-closing tap may fall below it.

Self-regulating heating cable

Unit 332Long dead legs: the limits, trace heating and upgrades

Trace heating cable whose output rises where the pipe is cold and falls where it is warm, so it cannot overheat any part of the run.

Self-sealing valve

Unit 334Compression at the foot of the stack, and putting faults right

A waste valve that replaces a water trap with a flexible membrane. It opens to let waste out, closes when flow stops, and stays tightly closed under back pressure.

Self-siphonage

Unit 334Traps, seal depths and how a trap loses its seal

Loss of the seal from the trap of the appliance that is discharging, caused by the vacuum behind a plug of water running full bore in the branch.

Semi-gravity system

Unit 333Open-vented systems: cistern, vent, feed and the neutral point

A heating system with a pumped heating circuit and gravity-circulated hot water primaries, usually in 28 mm pipe. Now regarded as a system to upgrade.

Sensible heat

Unit 333Heat gains, pipework losses and what the design ignores

Heat that changes the temperature of a substance and can be measured with a thermometer. A person at rest gives off about 115 watts of it.

Sensor cable

Unit 333Running the cables and wiring the control system

The small cable carrying the signal from a temperature sensor back to a controller. It works at extra-low voltage and carries almost no current, but is sensitive to interference and to its environment.

Sensor eye

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

The infra-red emitter and receiver on a sensor tap that projects a beam of 200 to 260 mm and signals the solenoid when it is broken.

Separate system

Unit 334Sanitary pipework: the rules and the standard sizes

A below ground drainage arrangement with two sewers. The foul water is treated and the surface water is discharged untreated to a watercourse or soakaway.

separately occupied premises

Unit 331Backflow protection levels: point of use, zone and whole site

Parts of one building or site occupied by different people or businesses, such as flats fed from a common supply pipe or units in a shared building. Schedule 2 paragraph 15(4) requires backflow protection where necessary to stop backflow passing between them.

Septic tank

Unit 334Cesspools and septic tanks: how they work and what they need

A multi-chamber underground tank in which solids settle and partly decompose, and the separated liquid passes on to secondary treatment.

Sequence of work

Unit 336Method statements: what they are and contain

The order in which the stages of a job are carried out, set so that each stage leaves the site safe for the next and so that trades are not put at risk by each other.

Series pattern

Unit 333Underfloor pipework: patterns, insulation, screed and testing

An underfloor pipe layout running back and forth across the room at set centres, with the flow taken first to the coldest part. Also called the meander or serpentine pattern.

Serpentine absorber

Unit 335Collectors: flat plate, evacuated tube and unglazed

An absorber in which a single continuous S-shaped tube carries the fluid across the plate, lengthening its path.

Service and maintenance contract

Unit 336Programmes for contract work: new build and maintenance

An agreement to keep a building's plant and systems functional, safe and in working order over a period, through scheduled visits and agreed response times.

Service history

Unit 332Manufacturer instructions, flow charts and service history

The record of what has been done to a system since it was commissioned, including dates, tests, readings and parts replaced. It shows whether a fault has occurred before and how the system has been drifting.

service pipe

Unit 331Draining down, standing water and diagnostic readings

The pipe from the water main to the building, made up of the undertaker’s communication pipe and the customer’s supply pipe. A service pipe unused for a year or more should be disconnected from the main.

Service record

Unit 332Relief valves, strainers and pressures: the annual service

The written record of a maintenance visit, giving the date, location, tests performed, readings taken and parts replaced. BS EN 806-5 requires it to be stored so the data is auditable.

Service schedule

Unit 333Service histories and the commissioning record as your baseline

The manufacturer's list of the checks a particular appliance needs and the interval at which each is due.

Services clash

Unit 336The chain of command: who can give you an instruction

A point where two trades' installations are shown in the same place on the drawings, so one of them has to move.

Servicing clearance

Unit 332Siting the cylinder: weight, clearance and the discharge route

The free space that must be left around an appliance so that routine maintenance can actually be carried out and the appliance can be removed and replaced.

servicing valve

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

A small isolating valve fitted close to an appliance or float-operated valve so it can be shut off for repair without draining the system. Schedule 2 requires one on the inlet to every cistern, and one upstream and downstream of every category 4 mechanical backflow device.

Setting to work

Unit 332Commissioning: the documents and the running order

The first stage of commissioning, in which the system is started up and run for the first time under its designer's intended conditions.

Settlement tank

Unit 331Private water supplies: sources and responsibilities

A tank fed from the intake where suspended solids drop out before the water goes on to the filters, with a raised, screened outlet.

sewerage undertaker

Unit 331Approved contractors: certificates of compliance and other notices

The company responsible for the public sewers in an area, usually the same company as the water undertaker. It must be told and give approval before used disinfectant is discharged to a drain or sewer, and may require the disinfectant to be neutralised first.

Shading

Unit 335Orientation, tilt, shading and permitted development

Obstruction of the collector by trees, chimneys, aerials or other buildings. It removes radiation outright and is worst in the spring and autumn months.

Sheath

Unit 333Choosing and routing cable for heating controls

The outer covering of a cable. It holds the cores together and provides mechanical protection; it is not the insulation and is not a conductor.

Shock arrestor

Unit 331Check valves, water hammer and the mini expansion vessel

A vessel with a piston or diaphragm cushioned by inert gas or air that absorbs the energy of a water hammer wave.

Short cycling

Unit 331Booster sets: the pressure vessel and the control switches

A pump starting and stopping repeatedly at short intervals, which the pressure vessel is fitted to prevent.

Short retention system

Unit 335Greywater re-use: sources, treatment and storage limits

A greywater system that skims debris and lets particles settle, stores a small volume, and purges it if it is not used within about 24 hours.

Short-circuiting

Unit 331Linked and sectional cisterns in the plant room

Water passing straight from inlet to outlet without flowing through the whole cistern, leaving the rest to stagnate.

Shoulder seasons

Unit 335Orientation, tilt, shading and permitted development

Spring and autumn. The sun is low, shadows are long, and these months carry a large share of the annual solar yield.

Shower booster pump

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A pump fitted to a gravity shower that has less than about 1 m of head, to raise the pressure at the shower head.

Shower former

Unit 334Wet rooms: tanking, falls and the floor gully

A preformed sloping panel set into the floor of a wet room that builds in the fall to the outlet. On solid floors a screed can do the same job.

shower hose

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

The flexible hose between a bath mixer and a hand-held shower head. If it can lie below the bath's spill-over level the head becomes a submerged outlet and the tap gap is lost.

Shunt pump

Unit 332Secondary circulation: pump position, balancing and controls

A pump that circulates water within a large storage vessel during periods of low demand, evening out the temperature so no cool layer is left for bacteria to grow in.

Sight glass

Unit 335Air source heat pumps: frost, defrost and fault finding

A small window in the liquid line that shows the state of the refrigerant. Clear liquid is normal at steady state; persistent bubbles suggest undercharge or non-condensables.

Sign-off procedure

Unit 336Writing it down: forms, formats and who signs

The signatures recording that the assessment was completed, checked by the supervisor and approved, each with a name and a date.

Significant findings

Unit 336Writing it down: forms, formats and who signs

The important hazards, the people at risk and the control measures, which are what a written risk assessment has to record.

Significant result

Unit 334Performance testing a branch pipe for self-siphonage

The figure taken as the outcome of a repeated test. For performance testing it is the maximum loss of seal measured in any one of the repeats.

simplified method

Unit 331Cistern sizing, float valve refill and pipe design limits

The BS EN 806-3 pipe sizing method used for dwellings and similar buildings: starting at the last draw-off point, add the loading units section by section back to the source and read the pipe size for the material from Table 3, which builds in simultaneous demand and limits the length of the smaller sizes.

simultaneous demand

Unit 331Available pressure and flow, feed arrangements and loading units

The flow a pipe has to carry when several of the outlets it serves are in use at once. Not every outlet is used together, so the loading unit tables build in an allowance, sometimes called diversity, rather than adding every design flow rate.

Simultaneous discharge

Unit 334Testing a range of appliances for induced siphonage

Discharging two or more appliances at the same moment, as a performance test requires, so the pipework sees the flow it would at peak use.

single check valve (type EA/EB)

Unit 331RPZ valves and single and double check valves

A spring-loaded one-way valve that lets water flow downstream only and closes when flow stops or reverses. Type EA has a test point, type EB does not. Rated fluid category 2 both ways; used on each feed to a mixer, in the inlet group of an unvented cylinder and on each pump outlet in a booster set.

Single impeller pump

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A shower pump with one impeller fitted on the outlet of the mixer to boost the blended water.

Single impeller shower pump

Unit 332Shower pumps, accumulators and shock arrestors

A pump fitted after the shower mixing valve that boosts the mixed water to the outlet. Also used to boost an individual hot or cold outlet.

Single-family private dwelling

Unit 331Disinfection: which jobs need it and what disinfectant is used

A house occupied by one family. New installations and major extensions in one are flushed but not usually disinfected; the exception does not cover suspected contamination.

single-phase

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

An electrical supply from one live conductor and a neutral at 230 V, as in a house. A single-phase pump motor needs a capacitor to start and run; three-phase motors do not.

Sink waste disposal unit

Unit 334Macerators and waste disposal units: what commissioning must prove

A motorised grinder fitted under a kitchen sink that reduces food waste to a paste and flushes it to the drain through a 40 mm waste.

Siphon

Unit 334WC flushing: volumes, devices and overflow protection

A valveless flushing device that starts the flush by lifting water over a weir into the down leg. It cannot leak past a seat, but it needs physical effort to operate.

Siphonic WC

Unit 334Sanitary appliances: how many, how much space, which type

A WC pan that clears its contents by setting up a siphon in the trapway, so a difference in air pressure draws the contents out.

Siphonic WC pan

Unit 334Traps, seals and appliances: the checks before you test

A pan with a double or restricted trapway that fills on flushing and starts a siphon, which pulls the contents out.

Site conditions

Unit 336Project delays and contingency planning

The physical circumstances of the site: ground conditions, access, storage, occupancy and anything else that limits how and when work can be done.

Site diary

Unit 336Project delays and contingency planning

The daily record kept on site of what happened, including weather, stoppages and visitors, used as evidence if a delay is disputed.

Site engineer

Unit 336The design team: architect, engineers and surveyor

A site-based engineer responsible for setting out the works and controlling levels so that the building is constructed in the correct position.

Site induction

Unit 336Site procedures: inductions, toolbox talks and safety memos

The briefing every person receives before first working on a site, covering the site's hazards, rules, traffic routes, welfare facilities and emergency arrangements.

Site instruction

Unit 336Variation orders: pricing extra time and extra cost

A written instruction issued on site telling the contractor to do something differently. It is one of the acceptable written forms for instructing a change.

Site management team

Unit 336The chain of command: who can give you an instruction

The people responsible for running the site day to day, to whom the trade supervisors report and who co-ordinate the trades against the programme.

site plan

Unit 331Design information: manufacturer data, customer feedback and scale plans

A plan of the building on its plot, usually at 1:500 or 1:1000, showing the incoming main, the boundary stop valve for each dwelling, the drains and any external pipe runs. It is where the connection point for each dwelling is found.

Site readiness

Unit 336Sequencing with other trades and site readiness

The state of the building's preparation for a following trade: whether the preceding work, openings, fixings and finishes needed are actually complete.

Site supervisor

Unit 336Who does what: responsibilities on a building services job

The building contractor's main representative on site, responsible for the day-to-day running of the site including budgets, staffing and deliveries. Also called the construction manager or project manager.

Site survey

Unit 335The pre-installation survey: deciding whether a job can go ahead

The visit at which the building, its services and its surroundings are measured and assessed against the conditions a proposed installation needs.

Site-specific risk assessment

Unit 336The five steps of a risk assessment

An assessment written for one job at one location, taking account of the actual hazards, people and conditions found there.

Sleeve

Unit 335Installing to the standards: pipework, penetrations and insulation

A tube built into an opening through which a pipe passes, allowing movement and protecting the pipe from the structure.

Slinky

Unit 335Ground source heat pumps: the four collector types

A continuous overlapping coil of collector pipe laid in a trench, so that more pipe fits into each metre of trench.

Slippage

Unit 336Monitoring progress: readiness, slippage and who to tell

The amount by which an activity is behind the date the programme shows for it.

Slow sand filter

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

A filter of fine sand, 0.15 to 0.30 mm, on which a biological layer removes micro-organisms; cleaned by scraping the top layer.

Sludge

Unit 334Cesspools and septic tanks: how they work and what they need

The settled solids at the bottom of a septic tank. Most is removed when the tank is desludged, but some is left as an anaerobic seed.

Small bore

Unit 333Flow rate and pipe size: from kilowatts to millimetres

Conventional domestic heating pipework, typically 15 mm to 28 mm, run as a two-pipe circuit and sized to a maximum velocity of about 1 m/s.

Smallbore heating system

Unit 333Microbore systems: manifolds, pipe sizes and circuit limits

A heating system whose circulation pipework is normally 15 mm to 35 mm outside diameter. The ordinary domestic two-pipe system is smallbore.

Smoke machine

Unit 334Locating a leak after a failed air test

The equipment that generates smoke under pressure for a smoke test, as an alternative to a chemical smoke cartridge.

Smoke test

Unit 334Locating a leak after a failed air test

A leak location method in which smoke is introduced into pressurised pipework and leakage is seen where it escapes. It must be avoided on plastics.

Snagging

Unit 336Site procedures: inductions, toolbox talks and safety memos

Identifying and listing defects or unfinished items so that they can be put right before the work is accepted.

Snagging list

Unit 336Accepting finished work: snagging, records and handover

The list of outstanding items and defects recorded at inspection, to be corrected before work is fully accepted.

Snail pattern

Unit 333Underfloor pipework: patterns, insulation, screed and testing

An underfloor pipe layout spiralling inward and returning between its own runs, so flow and return alternate and the surface temperature is very uniform. Also called bifilar or spiral.

Soakaway

Unit 334Combined, separate and partially separate drainage

A pit or trench that lets collected surface water infiltrate into the ground rather than run to a sewer or watercourse.

Soda crystals

Unit 334Blockages: where they form and how they are cleared

Sodium carbonate crystals dissolved in hot water to clear grease and soap residues from waste pipes. They are not caustic soda, which must not be used for this purpose.

Sodium hypochlorite

Unit 331Disinfection: which jobs need it and what disinfectant is used

The usual chlorine disinfectant, to BS EN 901; at 5 per cent available chlorine, 1 litre per 1,000 litres of system water gives 50 mg/l.

Soil water

Unit 334Occupancy, provision and the information a design starts from

The discharge from WCs and urinals, containing human waste. It is kept separate in design terms from waste water, which is the discharge from basins, baths, showers and sinks.

Sol-air temperature

Unit 333Heat gains, pipework losses and what the design ignores

The combined effect of air temperature and solar radiation on a surface. It explains why a building gains heat from sun-warmed surrounding air as well as from direct sunlight.

Solar collector

Unit 332Thermal stores and solar thermal: their pipework layouts

The panel or tube array that absorbs solar radiation and passes the heat to the transfer fluid. Made as a flat plate or as evacuated tubes.

Solar fraction

Unit 335Solar thermal: what it delivers and how the circuit works

The share of the annual hot water demand met by the solar system. A well-designed UK system achieves about 60 per cent.

Solar gain

Unit 333Heat gains, pipework losses and what the design ignores

Heat gained from direct sunlight through glazing and onto the fabric. It varies with orientation, season and time of day, and is largest on south-facing surfaces.

Solar irradiation

Unit 335Orientation, tilt and shading: judging a site for solar

The solar energy falling on a surface over a period, measured in kilowatt hours per square metre. It varies with orientation, tilt, location and shading.

Solar photovoltaic (PV)

Unit 335Micro-renewable technologies: what each one produces

Silicon cells that convert solar radiation directly into d.c. electricity. Entirely different from solar thermal despite looking similar on a roof.

Solar pre-heat

Unit 332Solar and twin-coil cylinders: which coil takes which source

The role solar thermal plays in a hot water system. It raises the temperature of the store as far as the sun allows, leaving the auxiliary source to make up the rest.

Solar thermal system

Unit 335Micro-renewable technologies: what each one produces

A system that uses solar radiation to heat a fluid in a roof collector, and transfers that heat to stored hot water. It produces heat only.

Solder creep

Unit 333Terminations and joints: making the connection last

The gradual flow of solder under the pressure of a clamped joint, which loosens a connection over time. It is why tinned conductor ends are not permitted in screw terminals.

Solenoid valve

Unit 331Large cisterns: warning pipes, overflows and inlet valves

An electrically operated valve in which an electromagnet lifts a plunger to open the valve and a spring closes it when the coil is de-energised. On a cistern it is signalled by a float switch.

Solvent weld

Unit 334WC macerators: how they work and how the outlet runs

A jointing method for plastic pipe in which cement chemically fuses the pipe and fitting. It is the only plastic jointing allowed on macerator discharge pipework.

Sound power level

Unit 335SCOP, SPF and system efficiency: the honest figures

A measure of the acoustic energy a unit emits, quoted on the energy label. It is a property of the machine, and is used with distance and siting to judge the noise a neighbour will actually hear.

Soundness test

Unit 331Soundness testing: test pressures for metal and plastics pipework

The pressure test that proves the pipework will hold water at more than its working pressure without leaking, required by Schedule 2 paragraph 12.

Soundness testing

Unit 336The job specification and the method statement

Testing an installation for leaks under pressure, in accordance with the procedure named in the specification.

Source-to-emitter naming

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

The convention by which heat pumps are named: the first word is where the heat is collected from, the second is what the heat is delivered into. Ground-to-water collects from the ground and heats a wet system.

Space heating zone

Unit 333The building: layout, size and the order of the work

A part of a dwelling served by its own heating circuit with its own time and temperature control, normally through a motorised valve driven by a thermostat.

sparge pipe

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

The perforated pipe along the top of a slab urinal that spreads the flush water down the wall. Older guidance placed the pipe interrupter 150 mm above it; the Regulation figure is 300 mm above the spill-over level.

Special location

Unit 333Certification and notification for heating control work

For Part P, the zone around a bath tub or shower tray, extending to 2.25 m above floor level and 0.6 m horizontally, or a room containing a swimming pool or sauna heater. A kitchen is not one.

Specific heat capacity

Unit 332Recovery rate, reheat time and usable volume

The energy needed to raise one kilogram of a substance by one degree. For water it is about 4.18 to 4.2 kilojoules per kilogram per degree.

Specific heat extraction rate

Unit 335Sizing a ground collector: extraction rates and area

The heat that can be taken from each metre of collector, or each square metre of ground, without the ground cooling out. Quoted in W per metre or W per square metre.

Specification

Unit 331Visual inspection: the documents and the dry checklist

The design document giving pipe sizes, materials, storage volumes, pump duties and design pressures. A component that does not match it is reported to the manager.

spill-over level

Unit 331Backflow risk: the duty and the five fluid categories

The level at which water would run over the rim of an appliance, cistern or vessel. Every air gap is measured vertically from the lowest point of the outlet down to this level.

Spillover level

Unit 334Walking the finished system: the visual inspection on site

The level at which an appliance would overflow, normally the top of its overflow or the rim. Rodding points and branch vent connections are taken above it.

Split system

Unit 335Installing to the standards: pipework, penetrations and insulation

A heat pump split between an outdoor unit and an indoor unit, with refrigerant pipework between them, so system water stays inside the building.

Split system heat pump

Unit 335Monobloc, split, air-to-air and exhaust air: choosing the type

A heat pump with the evaporator outdoors and the condenser indoors, joined by refrigerant pipework that is run and connected on site. Site refrigerant work brings an F-Gas competence requirement.

Split washer

Unit 331Performance tests: measuring flow and pressure at every outlet

A damaged float-valve washer that seals at daytime pressure but lets by under the higher night-time pressure, causing a cistern to overflow at off-peak times.

Spray tap

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A tap that breaks the flow into a fine spray, cutting water use by about 20 per cent; rated at 0.04 l/s for sizing.

Spring

Unit 331Private water supplies: sources and responsibilities

A point where the water table meets the surface and ground water flows out. Deep-fed springs are reliable; shallow ones dry up in summer.

Spring return

Unit 333Stuck TRVs, motorised valves and heat with no demand

The spring in a motorised valve that closes it when the electrical supply to the actuator is removed.

Square entry

Unit 334Sizing a discharge stack: a worked example

A branch connection made square into a stack, without a sweep in the direction of flow. It gives a stack less hydraulic capacity than a swept entry.

Stabilise

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

To let a newly filled system settle: float valves shut, pressure settles and the water reaches the temperature of its surroundings before inspection and testing.

Stack effect

Unit 333Heat loss: the fabric route and the ventilation route

The movement of air caused by warm, less dense air escaping upward through flues and openings, drawing cold air in at lower levels. It increases the air change rate.

Stack vent

Unit 334Discharge stacks: sizes, the base, offsets and stub stacks

The dry part of a discharge stack above the highest branch connection, carried to atmosphere. It may be reduced to 75 mm in one and two storey houses.

Staged filling

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

Filling a large system section by section, proving each leak-free before the next is opened.

Staged limit

Unit 331Soundness testing: test pressures for metal and plastics pipework

A pass criterion applied at more than one point in time, as in Test B's 0.6 bar at 30 minutes and 0.8 bar at 150 minutes; each stage must be met on its own.

stagnation

Unit 331Cistern sizing, float valve refill and pipe design limits

Water standing still in a cistern or pipe for long enough to warm, lose its disinfectant and grow bacteria. Cisterns are not oversized and dead legs are avoided so that water is held for as short a time as possible.

Stagnation temperature

Unit 335Stagnation: the limitation designed into every solar system

The maximum temperature a collector reaches with no heat being removed. Flat plates reach roughly 150 to 200 °C and evacuated tubes exceed 250 °C, and components are rated against this figure.

Standard Assessment Procedure (SAP)

Unit 332Working out the daily hot water demand for a dwelling

The government method for assessing the energy performance of dwellings. Its hot water demand formula is 25 times the number of occupants plus 36 litres a day at 52 degrees.

Standard test conditions

Unit 335Selecting a heat pump: output, emitters, pipe and volume

Fixed laboratory conditions used to quote heat pump performance, commonly written A7/W35 for air at 7 °C and water at 35 °C.

Standby cistern

Unit 331Linked and sectional cisterns in the plant room

A spare cistern or compartment, required over 1,000 litres, that keeps the supply going while another is isolated for cleaning.

Standing heat loss

Unit 332Long dead legs: the limits, trace heating and upgrades

Heat lost from a store or from pipework to the surrounding air while nothing is being drawn off. It is limited by insulation and by keeping pipe runs short.

Starts per hour

Unit 333System volume, buffers and short cycling

The number of times a manufacturer permits a heat generator to start in an hour. It is the figure behind a minimum system volume requirement.

Static completion

Unit 332Commissioning: the documents and the running order

The state of an installation when all the pipework, appliances and wiring are physically finished but the system has not yet been set to work, tested and adjusted.

Static completion records

Unit 333The commissioning record: what to write down and why

The records of the pre-commissioning checks, required by BS EN 14336 before a system is set to work, showing the installation is complete, sound and safe.

Static head

Unit 333The expansion vessel: position, charge pressure and size

The pressure produced by the height of water above a point, roughly 0.1 bar for every metre. It sets the minimum charge pressure for the vessel.

Static lift

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

The vertical height the pump must raise the water, in a building the height from pump to the highest outlet or cistern.

static pressure

Unit 331Cistern sizing, float valve refill and pipe design limits

The pressure in a pipe when no water is flowing. BS EN 806-3 limits it to 500 kPa (5 bar) at any draw-off point; above that a pressure-reducing valve is fitted.

Statutory

Unit 332Statutory rules, standards and guidance: which document does what

Made or required by law. Statutory documents such as the Building Regulations and the Water Supply (Water Fittings) Regulations can be enforced in court; a voluntary standard cannot.

Statutory cancellation rights

Unit 336Quotation, estimate and tender: presenting the price

The customer's legal right to cancel a contract within a set period after signing, normally without penalty if confirmed in writing.

statutory defence

Unit 331Approved contractors: certificates of compliance and other notices

The protection Regulation 7(2) gives an owner or occupier who is prosecuted for a contravention: it is a defence to show that the work was done by an approved contractor and that the contractor certified it complied. Both halves are needed; approval without a certificate, or a certificate from someone who is not approved, fails.

Statutory inspection

Unit 331Visual inspection: the documents and the dry checklist

An inspection or test the water undertaker is entitled to make. BS 8000-15 clause 4.1.1 requires prior notice of it.

Statutory nuisance

Unit 335Heat pumps and permitted development: volume, boundary and noise

A nuisance, including noise, that a local authority can act against under environmental protection law. It is separate from planning control.

statutory regulation

Unit 331Design information: the Regulations, notification and BS EN 806

A rule made under an Act of Parliament, so it is law and breaking it is an offence. The Water Supply (Water Fittings) Regulations 1999 and the Building Regulations are statutory; a British Standard is not.

Statutory regulations

Unit 333The documents a designer works from, and which one wins

Requirements that carry the force of law, such as the Building Regulations, the Water Supply (Water Fittings) Regulations and the Gas Safety (Installation and Use) Regulations. They cannot be overridden by a standard or an instruction.

Steady-state conditions

Unit 333Setting the controls: flow temperature, hot water and defrost

The settled condition a system reaches once warm-up is over and temperatures have stopped changing. Commissioning readings are only valid when taken here.

Stirling engine

Unit 335Micro-renewable technologies: what each one produces

An external combustion engine driven by heating and cooling a sealed working gas. It is the engine used in domestic micro-CHP units.

Stock rotation

Unit 336Cost monitoring: storage, wastage and the monthly payment

Using older stored material before newer, so that nothing exceeds its storage life before it is fitted.

Stop end outlet

Unit 334Terraces, outlet positions and keeping a rainwater system working

An outlet fitted at the end of a gutter run, receiving water from one direction only.

stopvalve

Unit 331Materials and standards: dezincification, galvanic corrosion and flux

A screw-down valve used to shut off the water supply to a building or a section of pipework. Underground stopvalves of 15 to 50 mm are made to BS 5433; those above ground to BS 1010.

Storage capacity

Unit 332Sizing the cylinder: 45 litres per occupant and the storage formula

The volume of hot water a vessel holds, quoted in litres. It is set from the likely consumption and the recovery rate together.

Storage water heater

Unit 332Centralised and localised hot water: choosing between them

A heater that holds a quantity of heated water ready for use. The store is replenished with cold water as hot water is drawn off.

Store

Unit 335Solar thermal: what it delivers and what it cannot

The cylinder or thermal store into which a solar thermal system puts its collected heat. Without a store there is nowhere for the energy to go, which rules out an instantaneous-only hot water supply.

Stored energy

Unit 331Borehole pumps: packaged sets, controls and the accumulator

The work the pump has done compressing the air in an accumulator, released as flow when a tap opens.

Strain relief

Unit 333Visual inspection of the completed controls

Any arrangement, such as a cable gland, clamp or a length of slack, that stops the weight or movement of a cable pulling on its terminations.

Strainer

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A mesh filter fitted upstream of a valve to keep grit off its seat.

Stratification

Unit 332Direct, indirect and combination cylinders compared

The layering of water in a store by temperature, with the hottest water at the top. It lets the hottest water be drawn off first and is why the cold feed enters at the bottom.

Structural engineer

Unit 336The design team: architect, engineers and surveyor

The engineer responsible for the structure of a building, including loads, the frame and the foundations. Consulted on any question of load-bearing capacity.

Stub stack

Unit 334Discharge stacks: sizes, the base, offsets and stub stacks

A short unventilated stack, closed at the top, connecting ground floor appliances to a ventilated drain or ventilated discharge stack within set height limits.

stud partition

Unit 331Reading drawings: elevations, sections, specifications and site surveys

An internal wall built of vertical timber or metal studs covered with plasterboard. It is hollow, so heavy appliances need a timber fixing board behind the board.

Sub-base

Unit 335Siting outdoor plant: air source units and ground loops

The compacted layer of stone prepared beneath a concrete slab so the slab is supported evenly and does not settle.

Subcontractor

Unit 336The chain of command: who can give you an instruction

A smaller firm engaged by the main contractor to carry out a specific or specialised part of a contract, such as plumbing, heating or electrical work.

submerged outlet

Unit 331Backflow risk: the duty and the five fluid categories

An outlet, hose end or tap spout that sits below the water level of the appliance or vessel it discharges into. Because it is under water it gives a path for back siphonage, so it needs a backflow device.

Submersible pump

Unit 331Private water supplies: sources and responsibilities

A sealed centrifugal pump hung below the water in a borehole that pushes the water up, so it has no suction-lift limit.

Substitution

Unit 336Control measures and the hierarchy of control

Replacing something hazardous with something less hazardous that does the same job, such as a press fitting instead of a soldered joint.

suction and discharge

Unit 331Replacing faulty fittings: gauges, pressure reducing valves and pumps

The two sides of a pump: suction (inlet), where water enters, and discharge (outlet), where it leaves under pressure. Gauges on both sides show whether the pump is doing its job — the suction reading falls and the discharge reading rises to the figure on the data plate.

Suction and discharge pressure

Unit 331The commissioning record and the defects that go on it

The pressures on the inlet and outlet sides of a booster pump, recorded on the commissioning record.

Suitable and sufficient

Unit 336The five steps of a risk assessment

The legal standard a risk assessment must meet: it must identify the significant risks, be proportionate to them, and set out what will be done about them.

suitable for the circumstances

Unit 331Regulations 3 and 4: installer tests and user duties

The second Regulation 4 test: a fitting must be right for where and how it will be used, judged against temperature, corrosion, compatibility with other materials, ageing and fatigue, and permeability. An approved fitting can still fail this test, so only the installer, who knows the installation, can decide it.

Superheated water

Unit 332Unvented hot water: mains pressure and the overheating hazard

Water held as a liquid above its normal boiling point because it is under pressure. If the pressure is lost it flashes instantly to steam.

supply pipe

Unit 331Backflow protection levels: point of use, zone and whole site

The pipe carrying water at mains pressure from the water undertaker's main into and around the premises, up to the point where it feeds a cistern or an outlet. A common supply pipe is one shared by several separately occupied premises.

Support centres

Unit 334Primary ventilated stacks: the branch limits that decide the layout

The maximum spacing between pipe clips or brackets, set in BS 8000-13 by pipe material, size and whether the run is vertical or near horizontal.

Surcharge

Unit 334Air admittance valves, stack terminations and housing sites

The condition where the water level in a sewer or manhole rises above the top of the pipe, usually in heavy rainfall, which interrupts the air flow in a connected stack.

Surcharging

Unit 334When a branch is too long: ventilating pipes and air admittance valves

A drain running full and under pressure, so that it can back up into the pipework connected to it.

Surface pump

Unit 331Private water supplies: sources and responsibilities

A pump installed above the water, in a pump house or the building, that has to draw the water up by suction.

Surface water

Unit 331Private water supplies: sources and responsibilities

Water taken from streams, rivers, springs or lakes rather than from below ground. It varies with the weather and always needs filtration and disinfection.

Swarf

Unit 331Flushing: the legal order and the BS EN 806-4 method

Metal filings and cuttings left in pipework from cutting and deburring, removed by flushing.

Swept connection

Unit 334The visual inspection: what a completed system must show

A branch fitting whose entry is curved in the direction of flow, so discharge joins the main pipe smoothly instead of striking the opposite wall.

Swept entry

Unit 334Joining branches to the stack: cross-flow and the no connection zone

A branch connection curved in the direction of flow so the discharge joins smoothly, reducing blockage and suction. The opposite is a square or knuckle entry.

Swept tee

Unit 332Insulation, dead legs and secondary circulation

A tee fitting with a curved branch that lets water join the main flow smoothly, used where a secondary return joins the cold feed of an unvented cylinder.

Switched fused spur

Unit 333Electrical faults on the controls: supply, fuses and wiring

The switched, fused connection unit through which a heating control system is supplied, fitted with a 3 A fuse.

Switched live

Unit 333Zone valves: two-port, mid-position and diverter

A live conductor that is only energised when a control has called for heat, as distinct from the permanent live that is always energised.

Symptom

Unit 332Questioning the end user before you touch anything

What the system does that shows something is wrong, such as cold water at the taps or a dripping discharge pipe. The symptom is what you observe; the fault is what causes it.

System boiler

Unit 333Sealed systems: expansion vessel, filling loop and safety valve

A boiler containing the pump, expansion vessel and sealed system safety controls inside its own casing, so they do not have to be installed separately.

System design

Unit 335Law, standards and schemes: what MCS is and is not

The calculated scheme for an installation, including heat loss, emitter sizes, flow temperatures, pipe sizes and controls. It is one of the three strands an installation is built from.

System designer

Unit 333Filling the system before the controls are proved

The person who determines the system's parameters, including expansion vessel size and charge pressure, so that all components work together.

System efficiency

Unit 335SCOP, SPF and system efficiency: the honest figures

The efficiency of the whole heating installation: the heat pump plus its auxiliaries, distribution pipework, controls and storage losses. It is what the customer actually pays for.

system history

Unit 331System history: commissioning records, logbooks and inspection frequencies

Everything recorded about a system since it was handed over — the commissioning record, logbook entries, previous call-outs, parts replaced and alterations. It is the fourth source of fault-finding information after the end user, the manufacturer’s data and flow charts.

System III

Unit 334System types: primary ventilated, ventilated branch and secondary ventilated

The single stack system used in the United Kingdom, described in BS EN 12056-2. Each appliance has its own individually sized branch discharge pipe, running only partly full.

System labelling

Unit 336Using a method statement on site

Durable labels fitted to a completed installation carrying the information the next person needs, such as the fluid type, fill pressure, isolation points and hot surface warnings.

System not in regular use

Unit 331Disinfection: which jobs need it and what disinfectant is used

An installation with low or no turnover, such as a school over the summer, where standing water is a contamination risk and disinfection is triggered.

System schematic

Unit 333Functional testing, commissioning and handover

A drawing of the system showing its circuits, components, valves and isolation points, so that anyone servicing it later can understand it without tracing pipes.

System volume

Unit 333Heat pump fault patterns: temperature difference and pressures

The total quantity of water in circulation. A heat pump needs enough volume in circuit to run steadily rather than cycling.

Table 3 (BS EN 806-3)

Unit 331Pipe sizing from BS EN 806-3 tables and pump duty

The pipe sizing tables of the simplified method, one per material, giving for each size the maximum loading units, the highest single appliance and the maximum section length. Table 3.2 is the copper table.

tabular method

Unit 331Accumulators on a weak main and the calculation sheet

The traditional UK pipe sizing method in BS 8558 Annex C (formerly BS 6700 Annex D), used for buildings other than dwellings. For each numbered section the loading units are converted to a design flow, a size is assumed, head loss and velocity are read off the pipe chart, the equivalent length of fittings is added, and the residual head is checked; if it is too low the size goes up and the section is repeated.

Tabulation method

Unit 333Working a room: a fabric and ventilation heat loss

Setting out a heat loss calculation in a table, one row per element and one table per room, so the figures can be checked and presented.

Tank-in-tank cylinder

Unit 332Heat pump cylinders: coil area, store temperature and reheat

A cylinder in which an inner potable vessel sits inside an outer body of primary water, so heat transfers through the whole surface of the inner tank rather than through a coil.

Tanking membrane

Unit 334Wet rooms: tanking, falls and the floor gully

The continuous waterproof layer, in sheet or liquid form, applied to the floor and lower walls of a wet room before the tiling goes on.

tap gap

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

The air gap between the lowest part of a tap, combination fitting or fixed shower head and the spill-over level of the appliance below it. It protects against back siphonage only: type AUK2 over domestic basins and baths, type AUK3 over sinks and hospital basins.

Task, individual, load, environment

Unit 336Manual handling: avoid, assess and reduce

The four headings of a manual handling assessment: what is being done, who is doing it, what is being moved and the conditions it is moved in.

Technical Handbooks

Unit 333The documents a designer works from, and which one wins

The Scottish equivalent of the Approved Documents. Section 6 covers energy, including U-value standards for new and existing dwellings.

Technical printout

Unit 333Starting up and balancing an underfloor manifold

The design output for the project listing each loop with its length, flow rate and the number of turns from closed its regulating valve should be opened.

Technical Product Information (TPI)

Unit 332Manufacturer instructions, flow charts and service history

The manufacturer's own documentation for an appliance covering its operation, servicing and repair. BS EN 806-5 requires it to be available, retained and followed.

Technical support

Unit 331The commissioning record and the defects that go on it

The manufacturer's help line, contacted when a pump set or accumulator still fails after the set-up procedure has been followed.

Tee piece

Unit 334Setting up the air test: plugs, manometer and charged traps

A three-way fitting used on a test connection, with a cock on each branch, so the pump and the manometer can both be connected and the air inlet closed.

Temperature and pressure relief valve (T&P)

Unit 332Temperature control, outlets and safety relief pipework

A valve fitted directly on an unvented storage vessel that opens on excess temperature or pressure, so that the stored water cannot exceed 100 degrees. No valve may be fitted between it and the vessel.

Temperature difference (delta T)

Unit 333Design temperatures: inside, outside and the difference

The difference between two temperatures, written with the Greek letter delta. In heat loss it is the internal design temperature minus the external design temperature.

Temperature drop

Unit 332Sizing a secondary circulation

The fall in temperature between the flow and the return of a circulation, written Δt. On a secondary hot water circulation it may not exceed 10 K, because the flow leaves at 60 °C and the return must arrive at not less than 50 °C.

Temperature equilibrium

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

The state where the water and the surrounding air are at the same temperature. BS EN 806-4 allows 30 minutes to reach it where they differ by more than 10 K.

Temperature lift

Unit 332Efficiency, carbon and cost: what the heat source decides

The difference between the temperature a heat pump takes heat from and the temperature it delivers heat at. The wider the lift, the lower the efficiency.

Temperature limiter

Unit 333The safety valve and the pressure gauge

The safety device that shuts the appliance down if the water temperature exceeds the maximum operating temperature. Most boilers have one built in.

Temperature maintenance

Unit 332Long dead legs: the limits, trace heating and upgrades

Holding water already at temperature in the distribution pipework, rather than reheating it, so that hot water is available at the outlet without running the tap.

Temperature relief valve

Unit 332Three levels of safety on an unvented cylinder

A safety device fitted directly on an unvented storage vessel that opens between 90 and 95 degrees C to discharge hot water, ensuring the stored water cannot reach 100 degrees C.

Temperature rise (T)

Unit 332Sizing the cylinder: 45 litres per occupant and the storage formula

The difference between the incoming cold water temperature and the temperature the water is heated to, in degrees Celsius. It appears in every heating calculation.

Tempering valve

Unit 332Thermal stores and solar thermal: their pipework layouts

An in-line blending valve on the outlet of a store that can exceed 80 degrees C, holding the temperature sent to the distribution pipework to no more than 60 degrees C.

Temporary decommissioning

Unit 332Commissioning records and dealing with defects

Isolating a system and taking it out of service until a faulty part can be replaced, so that it cannot be used in an unsafe condition in the meantime.

Temporary filling connection

Unit 333The filling loop, backflow protection and the cold fill pressure

A filling loop is a temporary connection only. While it is coupled the verifiable double check valve protects the main; as soon as filling is finished the loop is uncoupled, so no connection remains. The named air gaps — AA, AB, AUK1, AUK2, AUK3 — are tap and cistern arrangements, and none of them describes a filling loop.

temporary supply

Unit 331Scope of the Regulations: mains supplies in, private supplies out

A supply of undertaker's water for non-domestic purposes that is metered, lasts no more than one month (or three months with the undertaker's written consent) and cannot return water through the meter, such as a contractor's standpipe. Regulation 2(2) puts it outside the Water Fittings Regulations.

ten working days

Unit 331Regulation 5 notification: the list and the ten working days

The period the water undertaker has, from the day a Regulation 5 notice is given, to respond. If it has not consented, refused or attached conditions by then, Regulation 5(5) deems consent granted unconditionally and work may start.

tender

Unit 331Accumulators on a weak main and the calculation sheet

A formal priced offer to carry out a described contract, submitted in competition with other contractors. It is supported by the calculation sheet, scale drawings, the specification and a bill of quantities so the price can be checked.

Term contract

Unit 336Pricing methods: take-off, bills of quantities and rates

An agreement to carry out work of a defined kind over a period, usually paid against a schedule of rates rather than a single fixed price.

Terminal fitting

Unit 331Performance tests: measuring flow and pressure at every outlet

The tap, shower or valve at the end of a pipe where water is drawn off and flow is measured.

Termination point

Unit 332Siting the cylinder: weight, clearance and the discharge route

The place where a discharge pipe ends and releases water, outside the building and where the discharge is visible but cannot scald anyone.

Test A

Unit 331Soundness testing: test pressures for metal and plastics pipework

The Water Regulations plastics test: pump 30 minutes at test pressure, reduce to one third, and the pressure must not fall below one third over 90 minutes.

Test B

Unit 331Soundness testing: test pressures for metal and plastics pipework

The Water Regulations plastics test: pump 30 minutes at test pressure, then a drop of under 0.6 bar in the next 30 minutes and under 0.8 bar over 150 minutes, each stage met on its own.

Test condition notation

Unit 335Coefficient of performance: measuring what a heat pump saves

The shorthand attached to a quoted efficiency figure, giving the source and output temperatures. A7/W35 is air in at 7 °C, water out at 35 °C; B0/W45 is brine in at 0 °C, water out at 45 °C.

Test nipple

Unit 334Setting up the air test: plugs, manometer and charged traps

The small connection point built into a test plug or cap to which the test hose is attached.

Test plug

Unit 334Setting up the air test: plugs, manometer and charged traps

A mechanical or inflatable stopper fitted into the open end of a pipe to seal it for testing. An inflatable one is often called a drain bag or test bag.

test point

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

A small tapping on a backflow device to which a gauge can be connected so the device can be tested in place. A device with test points is verifiable; a type EA check valve has one, a type EC double check valve two and an RPZ valve three.

Test pressure

Unit 331Soundness testing: test pressures for metal and plastics pipework

The pressure a system is tested at: not less than 1.5 times the maximum pressure it is designed to be subjected to in operation.

Test record

Unit 333The pressure test, the pour and the 21 day cure

The document stating the test pressure used and that no leaks were found, required by BS EN 1264-4 before the screed is laid.

Thermal actuator

Unit 333The underfloor manifold: blending, balancing and safety

The electrically operated head on the return bar of a manifold that opens or closes one circuit in response to that room's thermostat.

Thermal conductivity (k-value)

Unit 333Heat loss: the fabric route and the ventilation route

How readily a material conducts heat, in watts per metre kelvin. It is a property of the material regardless of how thick it is.

Thermal cut-off device

Unit 334Sink waste disposal units: jams, overloads and blockages

A protective device that switches a motor off when it overheats, for example when the grinding blades jam. It must be accessible so it can be reset after the cause is cleared.

Thermal disinfection

Unit 332Disinfection: when it is needed and the figures

Disinfecting a hot water system with heat instead of chemicals, by raising the stored water so outlets stay at or above 65 degrees C and flushing every outlet at that temperature.

Thermal expansion

Unit 333Pipework: clip spacing, expansion and insulation

The increase in length of a pipe as it heats up. Plastic heating pipe grows about 10 mm per metre at 60 °C where it is free to move.

Thermal lag

Unit 333The underfloor heat-up, final balancing and set-back

The delay between a heating system starting and the room reaching temperature, caused by the mass of the floor that has to be warmed first.

Thermal mass

Unit 333Underfloor heating: floor temperatures, output and comfort

The heat stored in the floor structure. It steadies room temperature and evens out the heat output, but it also makes the system slow to respond.

Thermal resistance (R-value)

Unit 333Heat loss: the fabric route and the ventilation route

The resistance of a layer of material to heat flow, found by dividing its thickness in metres by its k-value. R-values of the layers are added together to find a U-value.

Thermal shock

Unit 333Multiple boilers, low loss headers and hydraulic separation

The rapid cooling or heating of a component, such as a boiler heat exchanger, which can lead to failure of the material.

Thermal shut-off test

Unit 332Combination boilers, heat exchangers and mixing valves

A test on a thermostatic mixing valve in which the cold supply is isolated and the mixed water monitored. The outlet flow should stop quickly, proving the valve fails safe.

Thermal store

Unit 332Thermal stores and solar thermal: their pipework layouts

A vessel storing primary water heated by a boiler, through which mains cold water passes in heat exchangers to be heated on demand. Also called a water jacketed tube heater.

Thermal transmittance (U-value)

Unit 333Heat loss: the fabric route and the ventilation route

The rate of heat transfer through an element of a building, in watts per square metre kelvin. The lower the U-value, the better the element keeps heat in.

Thermostatic blending valve

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A valve that mixes hot and cold to a set safe temperature before the tap, so a sensor tap cannot scald.

Thermostatic mixing valve (TMV)

Unit 331Balancing, mechanical controls and functional testing

A mixing valve that holds a set outlet temperature. BS 8558 notes it may not need balanced hot and cold pressures; the manufacturer's instructions decide.

Thermostatic radiator valve (TRV)

Unit 333Programmers, thermostats and the wiring centre

A self-acting valve that senses the air around it and throttles the water into its own radiator. It cannot switch the boiler off, so it may never be the sole control.

Thermosyphon

Unit 335Solar thermal: what it delivers and how the circuit works

Natural circulation caused by density difference, hot fluid rising and cool fluid falling. It requires the store to be above the collector.

Three-port mixing valve

Unit 333Y-plan: the mid-position valve and how it differs

A valve that blends cooler return water into the flow to control the temperature of a circuit, for example an underfloor circuit. It does not select between circuits.

Tilt

Unit 335Orientation, tilt and shading: judging a site for solar

The angle of a collector from the horizontal. A fixed collector uses a compromise angle, about 35° in the UK.

timber fixing board

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A length of timber fixed between or across the studs of a partition wall so that a wall-hung basin or bracket has something solid to screw into. Needed on plasterboard partitions; solid brick, blockwork and concrete take fixings directly.

Time switch

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A clock-controlled switch that opens a solenoid valve on a urinal supply only during the hours the building is occupied.

Timesheet

Unit 336Resources: labour, materials, plant and vehicles

The weekly record each employee completes of hours worked and jobs carried out, used to calculate wages and to inform future estimates.

title block

Unit 331Reading drawings: elevations, sections, specifications and site surveys

The panel, usually in the corner of a drawing, giving the project, the drawing number, the date, the revision and the scale. Read the scale from it before measuring anything off the drawing.

TMV2

Unit 332Limiting outlet temperature: bath limits and TMV types

The certification class for thermostatic mixing valves in domestic installations, tested against BS EN 1111 and BS EN 1287.

TMV3

Unit 332Limiting outlet temperature: bath limits and TMV types

The certification class for thermostatic mixing valves in healthcare and commercial installations, tested against NHS specification D08.

TN-C-S (PME)

Unit 333Earthing and bonding a heating control circuit

An earthing system in which the distributor combines neutral and earth in one conductor up to the cut-out, and the installation takes its earth from that combined conductor. Also called protective multiple earthing.

TOG rating

Unit 333Underfloor heating: floor temperatures, output and comfort

A measure of the thermal resistance of a floor covering. Coverings over underfloor heating should be below 1 TOG and never above 1.5, covering and underlay together (BS EN 1264).

Toolbox talk

Unit 336Site procedures: inductions, toolbox talks and safety memos

A short informal meeting held on site, usually before the day's work, to deal with one matter of health and safety or safe working practice.

Total floor area

Unit 333Zoning: how many zones, and what each one controls

The floor area within the insulated envelope of the dwelling, including internal cupboards and stairwells. It is the figure compared with 150 m² for zoning.

Total flow rate (Qtot)

Unit 334Discharge units, frequency factors and the flow rate formula

The design flow rate where continuous flows or pumped discharges are also connected. These are added to Qww without any reduction.

Trace heating

Unit 332Long dead legs: the limits, trace heating and upgrades

An electric heating cable run along a pipe, under its insulation, to keep the water inside at a set temperature. It removes the need for a secondary return.

Traceability

Unit 334What a sanitation commissioning record must contain

The ability to trace a recorded result back to the person, date and equipment that produced it, so a later query can be answered.

Trade supervisor

Unit 336Running the job: managers, clerk of works and supervisors

The person who runs one trade's work on a site, allocating duties to the operatives under their direct control and co-ordinating with other trades.

traditional loading units

Unit 331Cistern sizing, float valve refill and pipe design limits

The older UK loading unit scale kept in BS 8558 Annex C for buildings other than dwellings: WC 2, basin 1.5 to 3, bath 10, shower 3, sink 3. The numbers differ from the BS EN 806-3 scale, so the two are never mixed in one calculation.

Trail-off

Unit 334Rectifying, re-commissioning and handing back

The last dribble of water at the end of an appliance discharge, which runs back into the trap and refills the seal. It is why baths and sinks siphon less readily than basins.

Trap

Unit 334Traps, seal depths and how a trap loses its seal

A pipe fitting, or part of an appliance, that holds liquid to stop foul air passing from the drainage system into the building.

Trap seal

Unit 334Traps, seal depths and how a trap loses its seal

The depth of water held in a trap, measured in millimetres. Seals are 75 mm or 50 mm depending on the appliance, and at least 25 mm must remain after use.

Trapped gully

Unit 332Discharge pipework: the tundish, D1 and D2

A drainage fitting with a water seal. A discharge pipe terminating in one ends below the fixed grating and above the water seal.

Trend

Unit 333Service histories and the commissioning record as your baseline

The direction a reading moves across successive service visits. A trend can show a fault developing long before the system fails.

Trickle controller

Unit 331Specialist taps: infra-red, non-concussive, spray and urinal controls

A urinal control that lets the cistern fill only very slowly if no movement is detected for a set time.

Tubular trap

Unit 334Checking traps, branch pipes, gradients and falls

A trap formed from a bend of tube of the same bore as the waste pipe, so there is no reduction in flow area. An S trap has a vertical outlet, a P trap a near-horizontal one.

tundish

Unit 331RPZ valves and single and double check valves

An open funnel-shaped fitting that receives a discharge through a visible air gap and carries it to drain. The relief port of an RPZ valve or type CA disconnector discharges through a tundish giving a type AA air gap at least 300 mm above the floor.

Turbidity

Unit 335Greywater re-use: sources, treatment and storage limits

A measure of the cloudiness of water, in nephelometric turbidity units (NTU). Treated greywater for most uses must be below 10 NTU.

Twin and cpc cable

Unit 333Choosing and routing cable for heating controls

Flat sheathed cable containing an insulated line core, an insulated neutral core and a bare circuit protective conductor between them. The standard cable for domestic fixed wiring.

Twin coil cylinder

Unit 332Thermal stores and solar thermal: their pipework layouts

A cylinder with two heat exchanger coils: a lower one for the solar circuit and an upper one for the auxiliary heat source.

Twin impeller pump

Unit 331Flow limiting valves, pressure reducing valves and shower pumps

A shower pump with two impellers that boosts the hot and cold supplies separately on the inlet side of the mixer.

Twin impeller shower pump

Unit 332Shower pumps, accumulators and shock arrestors

A pump fitted before the mixing valve with one motor driving two impellers, boosting the hot and cold supplies separately.

Twin-coil cylinder

Unit 332Solar and twin-coil cylinders: which coil takes which source

A storage vessel with two separate primary coils, one low and one high, so that two heat sources can serve different parts of the store.

Twin-entry radiator valve

Unit 333Microbore systems: manifolds, pipe sizes and circuit limits

A radiator valve that takes both the flow and the return into a single radiator tapping through a concentric spigot, used with microbore legs.

Two-pipe buffer

Unit 333System volume, buffers and short cycling

A buffer connected in series with the circuit, so all the flow passes through it and the emitters receive the generator's flow temperature.

Two-pipe system

Unit 333One-pipe, two-pipe and reverse return layouts

A heating layout with a separate flow main and return main. Every emitter draws from the flow and discharges into the return, so all emitters receive water at nearly the same temperature.

Two-port zone valve

Unit 333Zone valves: two-port, mid-position and diverter

A motorised valve that opens or closes one circuit. It is driven open by a motor and closed by a return spring, and carries an auxiliary switch.

Type AA air gap

Unit 331Linked and sectional cisterns in the plant room

An unrestricted air gap between a discharge pipe and the water it discharges into, so nothing can flow back.

type AB air gap

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

An air gap with weir overflow: as type AA, but measured to the critical level of a rectangular weir overflow cut in the wall of a cistern that can be closed with a lid and screened against insects. The gap is twice the inlet diameter. Rated category 5 both ways, and the usual mains back-up arrangement for a rainwater or greywater cistern.

type AD air gap

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

An air gap with injector: a horizontal jet, sometimes called a jump jet, throws water across a gap of 20 mm or twice the inlet diameter into the appliance. Rated category 5 both ways; found inside commercial washing and dishwashing machines and catering equipment.

type AF air gap

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

An air gap with a circular overflow, rated to fluid category 4. Used with type AB on large storage cisterns where the critical level of a small overflow cannot be predicted. Type AC, a submerged feed with air inlet, is rated category 3.

Type AG air gap

Unit 331Large cisterns: warning pipes, overflows and inlet valves

The air gap between a cistern inlet and the overflow level, at least twice the inlet diameter, that prevents backflow into the inlet.

type AUK1 air gap

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

An air gap with interposed cistern: a cistern with a type AG gap and overflow stands between the supply and a receiving vessel whose spill-over level is at least 300 mm below the overflow pipe and 15 mm below the bottom of the cistern. Rated category 3 for back pressure and 5 for back siphonage. A conventional WC suite is the everyday example and needs no further backflow device.

type AUK2 tap gap

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

The tap gap over a domestic wash basin, bath, shower tray or over-rim bidet, where the risk is fluid category 2 or 3. Back siphonage only, to category 3. Minimum gap by tap size: 20 mm up to G half, 25 mm up to G three-quarters, 70 mm above G three-quarters.

type AUK3 tap gap

Unit 331Tap gaps: AUK2, AUK3 and bath mixers with shower hoses

The tap gap over any sink, domestic or not, and over any appliance in premises needing a higher level of protection such as a hospital basin, where the risk is fluid category 4 or 5. Not less than 20 mm or twice the bore of the tap inlet, whichever is greater. Back siphonage only, to category 5.

type CA device

Unit 331Backflow devices: testing check valves and maintaining the RPZ valve

A backflow preventer with non-verifiable reduced pressure zones, rated for fluid category 3. It is tested by closing the upstream stopvalve and checking that nothing discharges from its port, and is replaced if it fails.

Type CA disconnection device

Unit 333The filling loop, backflow protection and the cold fill pressure

A backflow prevention device with an integral tundish, allowing a permanent connection to a fluid category 3 system such as a domestic heating primary.

type CA disconnector

Unit 331Filling loops and outside taps: protecting heating and garden connections

A non-verifiable disconnector: a small RPZ without test points, with two check valves and a chamber between them that opens to atmosphere through a tundish when upstream pressure is lost. The pressure zones differ by not more than 10 per cent. Rated category 3 both ways; used for a permanent connection between a sealed heating system and the supply pipe.

type DB pipe interrupter

Unit 331Filling loops and outside taps: protecting heating and garden connections

A pipe interrupter with atmospheric vent and moving element: water leaves through side holes covered by a rubber membrane, and when supply pressure is lost the membrane closes the holes and vents open to air. Back siphonage only, to fluid category 4. Used at the hose union tap or 300 mm above a porous irrigation hose in a house garden, fitted vertically with no valve downstream.

type DC pipe interrupter

Unit 331Mechanical backflow devices: type DC, installation rules and ratings

A pipe interrupter with permanent atmospheric vent: a brass fitting with no moving parts whose air holes are always open, so if back siphonage starts air is drawn in and the siphon breaks. Back siphonage only, to fluid category 5. Fitted vertically, discharging downwards, with no valve or restrictor downstream, at least 300 mm above the spill-over level of a WC pan or urinal served by a pressure flushing valve.

type HA hose union backflow preventer

Unit 331Filling loops and outside taps: protecting heating and garden connections

A small device that screws onto the outlet of a hose union bib tap; a spring and membrane close against backflow and admit air to the hose when pressure drops. Rated category 2 for back pressure and 3 for back siphonage. Permitted only, fitted continuously, on an existing unprotected hose union tap in a house.

Type HC diverter

Unit 331Check valves, water hammer and the mini expansion vessel

A diverter with automatic return built into modern bath/shower mixers that provides backflow protection for the hose.

type HUK1 hose union tap

Unit 331Filling loops and outside taps: protecting heating and garden connections

A hose union bib tap with two single check valves built in, one at the inlet and one at the outlet, and a test point on the body. Rated category 3 both ways. Because mechanical devices belong inside the building it is permitted only as a replacement for an existing unprotected outside tap; a new tap gets a double check valve inside.

Type of use

Unit 334The stack performance test: choosing appliances from Table NG.1

The classification used by Table NG.1 to set the number of appliances discharged: domestic, commercial or public, or congested.

U-value

Unit 333Floor insulation and the layers before the screed

The rate at which heat passes through a building element, in watts per square metre per kelvin. A lower number means better insulation; a ground floor target is 0.25 W/m²K.

ultrasonic measure

Unit 331Reading drawings: elevations, sections, specifications and site surveys

A hand-held instrument that measures distance by timing a pulse of sound reflected off a wall. Quick to use, but any obstruction between it and the wall gives a false reading.

Ultraviolet (UV) degradation

Unit 333Running the cables and wiring the control system

The embrittling and cracking of cable sheathing caused by sunlight. Any part of a cable run outdoors must be UV resistant or protected from sunlight.

Ultraviolet (UV) disinfection

Unit 331Private supply treatment: filtration, ultraviolet and house layouts

Disinfection by a 254 nm mercury lamp in a quartz sleeve that changes the cellular structure of micro-organisms so they cannot reproduce. Needs clear water and leaves no residual.

Un-boosted supply pipe

Unit 331Multi-storey supply: the mains limit and the break cistern

The supply pipe serving the lower floors of a tall building straight from the main, with no pump.

unbalanced pressures

Unit 331RPZ valves and single and double check valves

Hot and cold supplies to a mixer arriving at different pressures, for example mains cold and cistern-fed hot. The higher pressure can push water across into the lower pressure supply, so BS 8558 asks for comparable pressures and single check valves on each feed.

Unbalanced supply

Unit 332Looking before testing: classic installation defects

An arrangement in which the hot and cold supplies to a mixer are at different pressures. Mixers and thermostatic mixing valves may not blend correctly, and there is a risk of backflow or scalding.

Underfloor control pack

Unit 333Emitter load: correcting catalogue output to real conditions

A blending valve and dedicated pump that mix return water into the underfloor flow to hold it at the lower temperature underfloor circuits need, while radiators run hotter from the same generator.

Underfloor heating (UFH)

Unit 333Underfloor heating: floor temperatures, output and comfort

A wet heating system in which pipe circuits embedded in or under the floor make the floor itself the heat emitter, running at low water temperature.

Undersized riser

Unit 331Balancing, mechanical controls and functional testing

A riser too small to carry the design total flow. It cannot be balanced out and is referred to the designer.

Undersizing

Unit 335Air source heat pumps: the benefits and where they struggle

Selecting a heat source with less output than the building's design heat loss. An undersized heat pump runs continuously in cold weather, still fails to hold temperature, and leans on expensive back-up heat.

Undisturbed ground temperature

Unit 335Ground source heat pumps: stable source, higher cost

The temperature of the ground before any heat is drawn from it. Below the zone of seasonal variation it sits close to the annual average air temperature for the site.

undue consumption

Unit 331The Water Regulations: origin, enforcement and the five harms

One of the five harms: water used for its proper purpose but in far greater quantity than the job needs, such as a urinal cistern that goes on flushing all weekend in an empty building.

Unit (unvented)

Unit 332Units, packages, approval and commissioning records

A proprietary unvented hot water storage system supplied with all its components already fitted at the factory.

Unoccupied set-back

Unit 333The underfloor heat-up, final balancing and set-back

A control strategy that lowers the target room temperature by about 4 K during unoccupied periods instead of switching the heating off, so warm-up from the next occupied period is faster.

Unplanned maintenance

Unit 333Notifying the client, safe isolation and temporary decommissioning

Work carried out in response to a failure or an emergency, where the system has already stopped performing.

Unswitched fused spur

Unit 334WC macerators: how they work and how the outlet runs

A fixed electrical connection point with a fuse and no switch, used so an appliance such as a macerator cannot be casually switched off.

unvented cylinder

Unit 331RPZ valves and single and double check valves

A hot water storage cylinder fed directly from the supply pipe at mains pressure, with no vent pipe or cistern. Its expanded water would back into the supply, so its inlet group carries a single check valve.

Unvented hot water storage cylinder

Unit 333Boilers and cylinders: siting, access and whose rules win

A hot water storage vessel fed directly at mains pressure with no open vent or feed cistern. Its safety devices discharge through a D2 pipe to a safe, visible place outside.

Unvented hot water storage system

Unit 332Unvented hot water: mains pressure and the overheating hazard

A stored hot water system with no open vent pipe, fed directly from the cold water main so that the stored water is above atmospheric pressure.

Upstand

Unit 331Multi-storey supply: the mains limit and the break cistern

The vertical pipe rising from a drinking water header on which the automatic air inlet valve is fitted.

upstream

Unit 331Backflow risk: the duty and the five fluid categories

Towards the water undertaker's main, the direction water comes from. Downstream is the opposite direction, away from the main and towards the outlets; a backflow device protects everything upstream of it from whatever is downstream.

Upstream end

Unit 334Testing a range of appliances for induced siphonage

The end of a branch discharge pipe furthest from the stack. Discharges from appliances here pass every other junction, giving the worst pressure conditions.

Urinal slab

Unit 334Urinals: flush rates, controls and pressure flushing valves

A continuous urinal surface without individual bowls. It is counted for flushing purposes as one position for each 700 mm of width.

Usable volume

Unit 332Recovery rate, reheat time and usable volume

The portion of a cylinder contents that can be drawn off at a useful temperature before the delivery cools. Typically 70 to 80 per cent of net volume in a well-designed vessel.

user

Unit 331Regulations 3 and 4: installer tests and user duties

In Regulation 3, anyone who uses a water fitting on an undertaker's supply, including the owner and occupier of the premises. The user must not use a fitting in a way likely to cause one of the five harms, must not use a damaged, worn or faulty fitting, and is liable to prosecution where the installer cannot be traced.

UV disinfection

Unit 331Chlorine disinfection: the figures, the people and the samples

Ultraviolet water treatment fitted to deal with contamination in an incoming supply such as a private supply; it does not clean an already contaminated installation.

UV unit

Unit 331Cross connections: keeping rainwater and greywater apart from the mains

An ultraviolet lamp in a tube that disinfects water passing through it, used in rainwater and greywater treatment. Treatment does not change the fluid category: treated rainwater or greywater is still category 5.

Vacuum relief valve

Unit 332Composite valves, vacuum relief and anti-legionella valves

A valve that admits air when the pressure inside a vessel falls below atmospheric, preventing the vessel from collapsing inwards.

Valuation date

Unit 336Cost monitoring: storage, wastage and the monthly payment

The fixed date, usually monthly, on which the work completed and materials on site are measured so that an application for payment can be made.

Valve diagram

Unit 331Handover: the file and the demonstration

A diagram fixed in the building identifying every valve, an alternative to individual valve labels under BS EN 806-4 clause 4.9.4.

Valve exercise

Unit 331After handover: signing off and the routine user checks

Operating a stop valve at least once a year so it does not seize (BS 8558 clause 6.2.2.3).

Valve identification label

Unit 331Visual inspection: the documents and the dry checklist

The label BS EN 806-4 clause 4.9.4 requires on each valve so that what it isolates can be identified.

Variable cost contract

Unit 336Contract types: fixed cost, variable cost and cost plus

A contract where agreed rates are applied to the quantity of work actually carried out, so the final sum is not known at the outset.

Variable height control valve

Unit 331Large cisterns: warning pipes, overflows and inlet valves

An inlet valve whose shut-off level can be adjusted so the stored volume is reduced when occupancy is low.

Variation

Unit 333Presenting the design: schedules, quotations and tenders

A change to the work agreed after the quotation was accepted. It should be recorded in writing, with its price, before it is carried out.

Variation clause

Unit 336Variation orders: pricing a change the client asks for

A clause in a construction contract that allows the works to be changed after the contract has been signed, and sets out how such changes are valued.

Variation order

Unit 336Variation orders: pricing a change the client asks for

The document that records an agreement made with a client to alter the work specified in a building contract, stating the change in cost and in time.

VAT

Unit 336Building a price: a worked example

Value Added Tax, added to the price at the rate in force where the business is registered for it. It is shown separately from the price of the work.

Velocity

Unit 332Flushing hot and cold systems, and in what order

The speed at which water travels along a pipe, in metres per second. Flushing needs at least 2 m/s to lift and carry debris out of the system.

Ventilated branch discharge system

Unit 334System types: primary ventilated, ventilated branch and secondary ventilated

An arrangement in which individual branch discharge pipes are given their own ventilating pipes, used where a branch is too long, too steep or has too many bends to run unventilated.

Ventilated branch system

Unit 334Ventilated branches and secondary ventilated stack systems

A layout in which each appliance has its own branch ventilating pipe, used where appliances are in ranges or widely dispersed from the stack. Previously the ventilated or modified single stack system.

Ventilated void

Unit 333Joisted floors: emission plates, foil and output figures

The through-ventilated space under a suspended ground floor. Air moving through it disrupts a reflective foil system, so foil must not be used over one.

Ventilating stack

Unit 334Ventilated branches and secondary ventilated stack systems

A vertical dry pipe that carries ventilating air. It either collects branch ventilating pipes or cross-connects to a discharge stack, and terminates at atmosphere or into the stack vent.

Ventilation heat loss

Unit 333Heat loss: the fabric route and the ventilation route

Heat lost as warm air leaves the room and cold air replaces it, whether by infiltration or by mechanical ventilation. Calculated from room volume, air change rate, temperature difference and the 0.33 factor.

Venting

Unit 332Filling and venting at normal operating pressure

Releasing air from a system as it fills, by opening the highest draw-off points so that the air is pushed out ahead of the water.

Venturi

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

A deliberate narrowing in a waterway that speeds the flow and lowers the pressure, used in a gas instantaneous heater to operate the gas valve.

verbal discussion

Unit 331Sources of fault information: the end user and the manufacturer

Talking the fault through with the end user, face to face or by telephone, then asking follow-up questions to narrow the cause down. It is the recognised way of gathering the immediate history of a fault.

Verbal feedback

Unit 331Handover: the file and the demonstration

Asking the customer in conversation whether the installation meets their expectations, the right way to obtain feedback on a new system.

verifiable

Unit 331Backflow risk: the duty and the five fluid categories

Describes a backflow device that has test points, so its check valves can be tested in place without removing it. A non-verifiable device has no test points and can only be checked by taking it out.

verifiable check valve (EA, EC)

Unit 331System history: commissioning records, logbooks and inspection frequencies

A single (EA) or double (EC) check valve fitted with a test point, so that its operation can be proved in place. Under BS EN 806-5 it is inspected and maintained once a year.

Vertical borehole heat exchanger

Unit 335Ground collectors: trenches, slinkies, boreholes and ponds

Ground loop pipework installed in one or more drilled boreholes. Used where land area is limited, it reaches deeper and more stable ground at a significantly higher drilling cost.

Vertical lift

Unit 334Macerators and waste disposal units: what commissioning must prove

The rise in a pumped discharge pipe from a macerator or lifter. One lift is recommended, at the start of the run, before the pipe falls to the stack.

Vertical multi-stage pump

Unit 331Booster sets: duplicate pumps, packaged units and annual servicing

A centrifugal pump with several impellers stacked in a vertical column, each adding pressure, used on most booster sets.

Visco-elastic material

Unit 332Soundness testing to BS EN 806-4: procedures A, B and C

A plastics pipe material such as PE, PP, PEX, PA or PB that both stretches and creeps under pressure, so its pressure reading falls over time even without a leak.

Visible leakage

Unit 332Soundness testing: the Water Regulations tests

Water that can be seen escaping from the installation during a test. Any visible leakage fails the test regardless of what the gauge reads.

Visitable toilet

Unit 334Sanitary appliances: how many, how much space, which type

A toilet on the entrance level of a dwelling planned with enough space for most people to use it, including a wheelchair user, so the activity space in front of the pan is deeper than the standard.

Visual inspection

Unit 331Visual inspection: the documents and the dry checklist

The first commissioning activity: a walk of the whole installation with the pipes empty, comparing what has been built with the specification, drawings and manufacturers' instructions.

Voltage band

Unit 333Running the cables and wiring the control system

BS 7671's grouping of circuits by voltage. Band I covers extra-low voltage such as sensor and signalling circuits; Band II covers normal low voltage mains circuits.

Voltage indicator

Unit 333Proving dead: the indicator, the proving unit and three readings

A two-pole instrument used to establish the presence or absence of voltage. For safe isolation it must be made and maintained in accordance with HSE guidance GS38.

Volumiser

Unit 333Multiple boilers, low loss headers and hydraulic separation

A two-port buffer vessel fitted in series on the return purely to add system volume. One pump still serves both sides, so it does not separate the circuits.

Vulnerable component

Unit 331Soundness testing: current standards, equipment and procedure

A fitting that cannot take the test pressure, removed and replaced with temporary pipe for the test.

W-plan

Unit 333Y-plan and W-plan: mid-position against diverter

A fully pumped system controlled by a three-port diverter valve, which serves either the hot water or the heating. It gives hot water priority.

Wander lead

Unit 333Testing the finished controls: earth continuity and polarity

A long test lead used to reach from the origin of a circuit to a distant point, so a continuity measurement can be made without a second person.

Warning notice

Unit 333Safe isolation: the seven steps in order

A durable tag or notice fixed at the point of isolation stating that work is in progress, who applied the isolation and what is being worked on.

Warning pipe

Unit 331Large cisterns: warning pipes, overflows and inlet valves

An overflow pipe fitted to give warning of an impending overflow, discharging in a conspicuous position. On a cistern up to 1,000 litres it is the only overflow.

Warning to user label

Unit 332Questioning the end user before you touch anything

The indelible notice Approved Document G requires on an unvented hot water storage unit or package, visible after installation. It tells the user not to adjust any component and to switch the heater off and contact the installer if hot water flows from the discharge pipe.

Warranty

Unit 331The commissioning record and the defects that go on it

The manufacturer's guarantee on a component, which an unauthorised repair can void; a defective component goes back to the manufacturer and supplier.

Wash-down WC

Unit 334Sanitary appliances: how many, how much space, which type

A WC pan cleared by the weight and momentum of the flush water washing the contents through the trap.

Wash-down WC pan

Unit 334Traps, seals and appliances: the checks before you test

A pan emptied by the force of the flush water alone, with no siphon formed in the trapway.

Washout pipe

Unit 331Linked and sectional cisterns in the plant room

A drain pipe from the lowest point of a large cistern, discharging over a type AA air gap, used to empty it for cleaning.

Wastage

Unit 336Cost monitoring: storage, wastage and the monthly payment

Material paid for but not installed, whether through offcuts, damage, over-ordering or loss. It is measured by reconciling material issued against work installed.

Wastage allowance

Unit 336Building a price: a worked example

A percentage added to the measured materials to cover offcuts, breakages and material that is paid for but not installed.

waste

Unit 331The Water Regulations: origin, enforcement and the five harms

One of the five harms the Water Fittings Regulations exist to prevent: water escaping from the system to no purpose, such as a dripping overflow or a leaking joint.

Waste disposal unit

Unit 334Waste water lifters and sink waste disposal units

A motorised grinder fitted under a kitchen sink that reduces food waste to a paste which water carries into the drainage system.

Waste water

Unit 334Occupancy, provision and the information a design starts from

The used water discharged from basins, baths, showers, sinks, washing machines and dishwashers. It carries no human waste.

Waste water flow rate (Qww)

Unit 334Discharge units, frequency factors and the flow rate formula

The expected flow of waste water in part or all of a drainage system where only domestic sanitary appliances are connected, calculated as K times the square root of the sum of the discharge units.

Waste water lifter

Unit 334Macerators and waste disposal units: what commissioning must prove

A self-contained tank, pump and control unit that lifts waste water from below sewer level and discharges it into the drainage system through a backflow loop.

Waste water lifting plant

Unit 334Waste water lifters and sink waste disposal units

A packaged tank, pump and control unit that lifts waste water from below sewer level into the gravity drainage system. Covered by BS EN 12056-4.

Wastewater lifter

Unit 334Selecting appliances and solving awkward layouts

A unit that collects wastewater in a chamber and pumps it up to a gravity drain. Lifting plants are covered by BS EN 12056-4.

Wastewater lifting plant

Unit 334WC macerators and lifting plants: the checks that find the fault

A packaged tank, pump and controls that lifts wastewater to a drain above it. Faecal types are covered by prEN 12050-1 and must be vented above roof level.

Water Act 2003

Unit 331Scope of the Regulations: mains supplies in, private supplies out

The Act that updated water industry regulation in England and Wales: how water companies and licensed suppliers are regulated, charged and enforced. It is not where the plumbing rules come from. The Water Supply (Water Fittings) Regulations 1999 are made under section 74 of the Water Industry Act 1991 and came into force on 1 July 1999, four years before this Act existed.

water byelaws

Unit 331The Water Regulations: origin, enforcement and the five harms

The rules each water company used to make for itself under the Water Act 1945 to control fittings on its supply. Regulation 14 of the Water Fittings Regulations revoked them in England and Wales in 1999; Scotland still uses byelaws, the Water Supply (Water Fittings) (Scotland) Byelaws 2014.

Water conservation system

Unit 335The pre-installation survey: deciding whether a job can go ahead

A system that replaces wholesome water with water from another source for uses that do not need drinking quality, such as rainwater harvesting or greywater re-use.

water efficiency calculation

Unit 331Building Regulations Part G: notices and competent person self-certification

The calculation that shows a new dwelling's fittings will use no more than 125 litres of water per person per day, required by Part G. It must be sent to the building control body within 5 days of completion (Regulation 20E), and the completion certificate is unlikely to be issued without it.

Water Efficiency Calculator

Unit 331Design information: the Regulations, notification and BS EN 806

The government calculation method that adds up the water use of the fittings specified for a new dwelling to show it meets the 125 litres per person per day limit. The result is notified to building control.

water fitting

Unit 331The Water Regulations: origin, enforcement and the five harms

In the Regulations, any pipe, tap, valve, cistern, cylinder, appliance or other apparatus through which water from an undertaker passes or in which it is stored. The word covers far more than pipe joints: a bath, a washing machine and a boiler filling loop are all water fittings.

Water gauge

Unit 334The air test requirement: 38 mm water gauge for 3 minutes

A way of expressing a small pressure as the height of a column of water it will support, written mm wg. 38 mm water gauge is the pressure that lifts water 38 mm in a manometer.

Water governor

Unit 332Instantaneous heating: combi boilers and point-of-use heaters

A device fitted to the inlet of an instantaneous water heater to hold the flow through it steady, so the outlet temperature stays constant.

Water hammer

Unit 331Check valves, water hammer and the mini expansion vessel

A pressure wave set up when moving water is stopped suddenly by a quick-closing valve, giving a bang and vibration; it can reach twice the working pressure.

Water Industry Act 1991

Unit 331The Water Regulations: origin, enforcement and the five harms

The Act of Parliament that governs the public water supply and sewerage industry in England and Wales. Section 74 gives the power under which the Water Supply (Water Fittings) Regulations 1999 were made.

Water management logbook

Unit 331The commissioning record and the defects that go on it

The building's record of water-hygiene documents, into which the disinfection certificate and data sheets go at occupancy (PD 855468 clause 14).

Water Regulations Advisory Scheme (WRAS)

Unit 332Statutory rules, standards and guidance: which document does what

The body that publishes the Water Regulations Guide and the Water Fittings and Materials Directory, and operates the approval arrangements showing that a fitting complies with the Water Regulations.

Water Regulations Guide

Unit 331Design information: the Regulations, notification and BS EN 806

The WRAS publication that prints the Water Supply (Water Fittings) Regulations 1999 alongside the official guidance on meeting each requirement, including the backflow device tables. It is the installer's working reference, because the duty to comply falls on whoever installs the fitting.

Water sampling

Unit 331After handover: signing off and the routine user checks

Taking stored drinking water for analysis at intervals not exceeding six months except in single dwellings (BS 8558 clause 6.1.4.1).

water softener

Unit 331System history: commissioning records, logbooks and inspection frequencies

An appliance that removes calcium and magnesium hardness from the supply, usually by ion exchange: the water passes through resin beads that swap the hardness for sodium, and the resin is regenerated with salt. Because it swaps one ion for another it barely changes the pH, so the direct check on it is a hardness test on samples taken before and after the unit.

Water Supply (Water Fittings) Regulations 1999

Unit 331The Water Regulations: origin, enforcement and the five harms

The law governing the design, installation and use of water fittings in premises supplied by a water undertaker in England and Wales, made under section 74 of the Water Industry Act 1991 and in force from 1 July 1999. They replaced the water byelaws, are enforced by the water undertaker, and exist to prevent waste, misuse, undue consumption, contamination and erroneous measurement of water. Scotland has the equivalent Water Byelaws 2014 and Northern Ireland the 2009 Regulations.

Water test

Unit 334The water test and the gutter test: where each one applies

A test in which pipework is plugged and filled with water to check for leaks. On sanitary pipework it applies only below the lowest appliance and within a 6 m static head.

Water tightness test report

Unit 333The commissioning record: what to write down and why

The record of a soundness test, giving the date, the test pressure, the duration and the result, signed by the operative and where required witnessed.

water treatment unit

Unit 331Regulation 5 notification: the list and the ten working days

Any device that changes the quality of the water, such as a softener, filter or reverse osmosis unit. One that discharges waste water, or needs water to regenerate or clean itself, is notifiable under item 4(f) of Regulation 5.

water undertaker

Unit 331The Water Regulations: origin, enforcement and the five harms

The company appointed under the Water Industry Act 1991 to supply water in an area, and which owns the mains. It enforces the Water Supply (Water Fittings) Regulations 1999 in its area, must be notified of certain work before it starts, and decides whether to consent to it.

Water/air flush

Unit 331Flushing: the legal order and the BS EN 806-4 method

The alternative flush in BS EN 806-4 clause 6.2.3 using a pulsed water and air mixture at a minimum of 0.5 m/s in sections of no more than 100 m.

Waterless trap seal

Unit 334Smells and slow running: what each complaint points to

A trap seal formed by a membrane or valve rather than by standing water. Approved Document H allows a seal of 25 mm of water or equivalent, which covers these devices.

Waterlogged expansion vessel

Unit 332The three fault signatures and what each one means

A vessel whose diaphragm or bladder has ruptured, so water has filled the gas side and there is no compressible cushion left. It cannot take up expansion and the expansion valve discharges on every reheat.

Wavering out

Unit 334The six causes of trap seal loss, and how to tell them apart

Loss of a trap seal caused by wind-driven pressure fluctuations at an exposed vent terminal, which set the trap water rocking until it spills over the weir.

WC macerator

Unit 334WC macerators and lifting plants: the checks that find the fault

A unit behind or beside a WC that grinds the discharge and pumps it away through small-bore pipework, used where gravity drainage is not available.

Weather compensation

Unit 333Weather compensation, optimum start and home automation

A control function that maintains internal temperatures by varying the flow temperature from the heat generator relative to the measured outside air temperature.

Weeping joint

Unit 331Filling: avoiding air locks, stabilising and inspecting for leaks

A joint that lets a small amount of water past under pressure, remade after the fill while the pressure is low.

weir gauge

Unit 331Available pressure and flow, feed arrangements and loading units

A cup or jug with a slot cut in its side: held under a running outlet, the height the water reaches against the slot reads the flow rate on a scale. It checks flow rate, not pressure; if the flow spills over the top the reading is false and a flow meter is used instead.

weir overflow

Unit 331Air gap arrangements: types AA, AB, AD, AG and AUK1

A rectangular slot cut in the wall of a cistern, screened against insects, that lets water spill out at a known level. It is sized for the inlet flow and gives the critical level for a type AB air gap.

Welfare facilities

Unit 336Presenting a method statement: headings and format

The toilets, washing facilities, drinking water, rest and changing arrangements that must be available to workers, and whose location and access are stated in a method statement.

Well

Unit 331Private water supplies: sources and responsibilities

A dug shaft at least 1 m in diameter reaching down to ground water.

Wet room

Unit 334Wet rooms: tanking, falls and the floor gully

A fully waterproofed room with a walk-in shower, where the room itself acts as the enclosure and the floor falls to a gully.

Wheelhead valve

Unit 333Radiators: fixing height, brackets and valve connections

A hand-operated radiator valve with a turning head, giving simple on and off control at the emitter.

whole site protection

Unit 331Backflow protection levels: point of use, zone and whole site

A backflow device at the point of entry, where the supply pipe enters the premises, so the water undertaker's main is protected from everything on the site. Usually a type BA RPZ valve; required under Schedule 2 paragraph 15(4) between separately occupied premises or when the undertaker gives notice, and secondary to point of use protection.

Whole-house method

Unit 333Design temperatures: inside, outside and the difference

Designing a dwelling to a single internal temperature throughout instead of room by room. It reduces calculation but tends to oversize the system.

wholesome water

Unit 331Fluid categories: grading water and regrading a building

Water that meets the drinking water quality standards in the water supply regulations and is therefore fit to drink, cook with and wash in; the European standards call it potable water. Mains water from an undertaker is wholesome; private supply water counts as wholesome only if it meets the Private Water Supplies Regulations; rainwater and greywater never do.

WIAPS

Unit 331Approved contractors: certificates of compliance and other notices

The Water Industry Approved Plumber Scheme, the first scheme set up by the water companies through which a plumber can become an approved contractor under the Water Fittings Regulations.

Wind uplift

Unit 335Orientation, tilt, shading and permitted development

The negative pressure created by wind passing over a roof and array, which tries to lift the collectors and their fixings. It usually governs the fixing design.

Wiring centre

Unit 333Programmers, thermostats and the wiring centre

The junction box in which the supply, controls, valves, boiler and pump are interconnected, so the system wiring can be made and traced in one place.

Wiring system

Unit 333Choosing and routing cable for heating controls

The combination of cable, its method of installation and its support, taken together. Single cores in conduit and twin-and-cpc clipped to a wall are both wiring systems.

Witnessed test

Unit 331Soundness testing: current standards, equipment and procedure

A test whose pass is watched and signed for by a second person, so the record carries a signature as well as a figure.

Work at height

Unit 336Work at height: ladders, harnesses and the definition

Work in any place where a person could be injured by falling from it, including places at or below ground level. There is no minimum height.

Work at Height Regulations 2005

Unit 336Work at height: ladders, harnesses and the definition

Regulations applying to all work at height where there is a risk of a fall liable to cause injury. They require the work to be avoided where possible, and otherwise planned, organised and carried out by competent people with inspected equipment.

Work programme

Unit 336Work programmes: what they are and what they show

A document that plans work activity against the time frame of a job or contract, so that the work is completed to the agreed schedule and progress can be measured against it.

Work quality management system

Unit 336Site procedures: inductions, toolbox talks and safety memos

The agreed set of checks and records a company or site uses to control the quality of work, including stage inspections, test records and snagging lists.

Work restraint

Unit 336Work at height: ladders, harnesses and the definition

A system that prevents a person from reaching a position from which they could fall, as opposed to arresting a fall after it has begun.

working drawings

Unit 331Reading drawings: elevations, sections, specifications and site surveys

The dimensioned, scaled plans, elevations and details issued with the specification so the contractor can price the job and build from them.

working pressure

Unit 331Design information: manufacturer data, customer feedback and scale plans

The pressure at which an appliance is designed to operate. A thermostatic shower, unvented cylinder or booster set has a minimum working pressure and flow rate in its data sheet, and the cold water design must deliver them at the appliance.

workmanlike manner

Unit 331Regulations 3 and 4: installer tests and user duties

The standard of work Regulation 4(5) demands. Regulation 4(6) defines it as work that conforms to an appropriate British Standard, a specification approved by the regulator, or a method approved by the water undertaker, so it refers to documents, not to neatness.

Workmanship

Unit 334Defective workmanship: faults built in on the day

The standard to which an installation is actually built on site. For above ground drainage it is set out in BS 8000-13, which Approved Document H paragraph 1.37 refers to.

WRAS

Unit 331RPZ valves and single and double check valves

The Water Regulations Advisory Scheme, the industry body that publishes the Water Regulations Guide and guidance notes, approves fittings and materials, and accredits the testers who commission and test RPZ valves.

WRAS IGN 9-02-05

Unit 331Identifying non-wholesome pipework and testing for cross connections

The WRAS Information and Guidance Note that sets the colour code for reclaimed water pipes (green, black, green), cited by BS 8525-1 and Approved Document G.

WRAS Water Regulations Guide

Unit 331The Water Regulations: origin, enforcement and the five harms

The Water Regulations Advisory Scheme (WRAS) is the body the water suppliers set up to publish guidance on the Water Fittings Regulations and to test and list fittings that meet them. Its Guide explains how to comply but is not the law, and a WRAS listing is evidence of appropriate quality, not the statutory test.

Y-plan

Unit 333Y-plan and W-plan: mid-position against diverter

A fully pumped system controlled by a single three-port mid-position valve, which can serve the heating, the hot water, or both at once.

Yield coefficient

Unit 335Rainwater and greywater: what the building must offer

The proportion of rain falling on a collection surface that reaches storage, typically 0.7 to 0.8 on a standard pitched roof.

Zero-loss efficiency

Unit 335Collector performance: aperture area and the efficiency curve

The efficiency of a collector when the absorber and ambient air are at the same temperature, so there is no driving force for heat loss. Also called optical efficiency, it is the intercept of the efficiency curve.

Zone

Unit 333Zoning: how many zones, and what each one controls

An area of a dwelling heated by its own circuit, with its own valve, temperature control and time control, so it can be run independently of the rest.

zone protection

Unit 331Backflow protection levels: point of use, zone and whole site

A backflow device on the pipe serving one part of a site, such as a floor, a process area or each separately occupied premises fed from a common supply pipe, so that a risk in that zone cannot reach the rest of the building. It is secondary protection, additional to the point of use devices within the zone.

zone valve

Unit 331Isolation: required valves and the isolate, label, cap-off sequence

An isolating valve that shuts off one area or floor of a building’s system so that work can be done there while the rest stays in service.

Zoning

Unit 333S-plan plus and multi-zone wiring for larger houses

Dividing a dwelling's heating into separately controlled circuits, each with its own valve, time control and temperature control.

No matching terms

Try a different word, or check the spelling.