Glossary

Every key term across all PlumbMate units, in one place. Search by word, abbreviation or meaning.

… Search covers every term, including extended ones

48°C / 43°C / 41–43°C

Unvented

Three different figures. 48°C is the ADG3 ceiling at a domestic bath. 43°C is the Water Regulations ceiling at outlets in public buildings. 41–43°C is the TMV2 factory setting — a starting point, not a limit.

A7/W35

Heat Pumps

Test condition notation: 7°C air entering, 35°C water leaving. Ground source units use B for brine, as in B0/W45.

Absolute zero

Heat Pumps

The lowest possible temperature, −273°C. Everything above it contains some heat energy, which is why a heat pump can still collect heat from air that feels cold.

Absorber

Solar Thermal

The plate inside a flat plate collector, of copper, aluminium or stainless steel, that takes up the solar energy and passes it to the fluid channels bonded to it.

Accredited tester

Water Regs

A person qualified to commission and carry out the annual test of an RPZ valve assembly.

ACOP L8

Solar Thermal

The approved code of practice carrying the duty to assess and control the risk of legionella.

Active system

Solar Thermal

A system that moves the heat with a pump.

Air gap

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

An unobstructed, complete physical break between the lowest point of discharge and the spillover or critical level of the receiving vessel. Not less than 20 mm or twice the internal diameter of the supply, whichever is greater.

Unvented

The 25mm visible break at the tundish that prevents back-siphonage and shows when a valve is discharging.

Air-to-air heat pump

Heat Pumps

Collects from outside air and delivers warm air indoors. Provides no domestic hot water, so it rarely suits a whole-house UK retrofit alone.

Airlock

Solar Thermal

Air collected at a high point, blocking circulation. The first thing to suspect when the pump runs but no heat reaches the store.

Albedo

Solar Thermal

The share of incoming solar radiation reflected straight back to space by cloud and by surfaces.

Animal drinking trough

Water Regs

A vessel supplying drinking water to livestock. Fluid category 5, requiring an air gap, inflow control and a servicing valve.

Anti-freeze

Water Regs

An additive that raises a fire protection system from fluid category 2 to fluid category 4.

Anti-vacuum valve

Water Regs

A device with an air inlet that opens to admit air if a vacuum occurs at the inlet, breaking the siphon. Also called a vacuum breaker.

Anti-vibration mount

Heat Pumps

A resilient mounting breaking the path by which compressor vibration would travel into the building structure.

Aperture area

Solar Thermal

The area of a collector that admits sunlight. The figure used in the MCS energy calculation, and smaller than the overall area.

Approved contractor

Water Regs

A person approved by the water undertaker for the area, or certified by an organisation specified in writing by the regulator.

Approved Document G3

Unvented

The Building Regulations guidance covering hot water supply and safety, including unvented systems.

Article 2(3) land

Solar Thermal

Conservation areas, AONBs, National Parks, the Broads and World Heritage Sites. Solar equipment on a flat roof on such land requires prior approval.

Article 4 direction

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

A local authority direction withdrawing permitted development rights in a specified area.

Heat Pumps

A local authority direction withdrawing permitted development rights in a defined area.

Ascending spray bidet

Water Regs

A bidet with a spray inlet below the spillover level. Fluid category 5, never supplied directly from a supply pipe, and notifiable anywhere.

Atmospheric pressure

Unvented

The pressure of the surrounding air (about 1013 mbar at sea level), at which water boils at 100°C.

Atmospheric vent

Water Regs

An opening to the air that admits air to break a siphon, as in a DB or DC pipe interrupter.

Automatic flow limiting valve

Water Regs

A servicing valve with a variable orifice cartridge that caps the maximum flow rate irrespective of supply pressure.

Backflow

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

Water flowing back into the mains from an installation, carrying contamination with it. Prevented by devices appropriate to the fluid risk category.

Water Regs

Flow upstream — in a direction contrary to the intended normal direction of flow, within or from a water fitting.

Backpressure

Water Regs

Backflow caused by the pressure downstream becoming greater than the supply pressure, pushing fluid back.

Backsiphonage

Water Regs

Backflow caused by the supply pressure falling, creating a negative pressure that draws fluid back towards the main.

Backup heat source efficiency

Solar Thermal

An input to the MCS calculation. A boiler running in summer for hot water alone works well below its rated efficiency, so each solar kWh displaces more than a kWh of fuel.

Balancing

Heat Pumps

Setting each circuit's flow to match its emitter's designed output, so rooms reach temperature together rather than the nearest circuits taking more than they need.

Ballast

Solar Thermal

Mass added to a flat roof array to resist wind uplift. It must exceed the uplift with a margin, and the roof must be confirmed able to carry it.

Barrier pipe

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

Plastic pipe with an oxygen barrier layer in its wall. Without it, oxygen diffuses in continuously and corrodes every ferrous component in the system.

Water Regs

Plastics pipe with a permeation-resistant layer, for use where the ground may be contaminated by hydrocarbons.

Baseline pressure

Heat Pumps

The brine circuit pressure recorded at commissioning. The only reference by which a future engineer can recognise a slow loss from a buried collector.

BBA (British Board of Agrément)

Unvented

A certification body whose approval is used to show an unvented unit meets the required performance.

Benchmark record

Unvented

The commissioning record listing the cylinder details, pressures, pre-charge and confirmation the safety devices were tested.

Bib tap

Water Regs

A tap with a horizontal inlet, typically wall-mounted. One to which a hose cannot be connected presents a lower backflow risk.

Bivalence point

Heat Pumps

The outdoor temperature below which a bivalent system's supplementary heat source must contribute, where the falling output curve meets the rising demand curve.

Bivalent system

Heat Pumps

A heat pump paired with a second, different heat source that contributes below a defined outdoor temperature.

Boiling point

Unvented

The temperature at which water turns to steam; it rises as pressure increases.

Break tank

Water Regs

A cistern providing a physical air gap between the supply and a downstream system, usually with a pump to restore pressure.

Brine

Heat Pumps

The water and antifreeze mixture circulated through a closed-loop ground collector. Routinely runs below 0°C in normal operation.

Brine circulator

Heat Pumps

The pump moving the water and antifreeze mixture through the collector and evaporator. A parasitic load counting against the system's SPF.

BS 1010

Water Regs

The standard for above-ground screwdown stopvalves.

BS 1212

Water Regs

The standard for float-operated valves. Part 2 is the adjustable brass-bodied valve; Part 1 valves are not acceptable because the close level cannot be adjusted.

BS 1710

Water Regs

The standard for identification of pipelines and services — the basis for colour coding non-wholesome pipework.

BS 2580

Water Regs

The standard for plug cocks, acceptable underground in sizes 15 mm to 50 mm.

BS 2879

Water Regs

The standard for draining taps of the screwdown type.

BS 3445

Water Regs

The standard for fixed agricultural water troughs and water fittings.

BS 5163

Water Regs

The standard for cast iron gate valves, used at 50 mm and above.

BS 5422

Water Regs

The standard for thermal insulating materials on pipes, ductwork and equipment.

BS 5433

Water Regs

The standard for underground screwdown stopvalves of 15 mm to 50 mm nominal size.

BS 5502

Water Regs

The standard for buildings and structures for agriculture; Part 42 covers pig buildings.

BS 5970

Water Regs

The code of practice for the installation of thermal insulation.

BS 6351

Water Regs

The standard for electric surface heating — self-regulating trace heating used as frost protection.

BS 6700

Water Regs

The standard for the design, installation, testing and maintenance of water supply services.

BS 6920

Water Regs

The standard for suitability of non-metallic products in contact with water intended for human consumption, with regard to their effect on water quality.

BS 6956

Water Regs

The standard for jointing materials and compounds; Part 5 covers compounds for sealing screwed water fittings.

BS 6974

Water Regs

The standard for unsintered PTFE tape used for thread sealing, which must also satisfy BS 6920 Part 1.

BS 7593

Heat Pumps

The code of practice for preparing, commissioning and maintaining system water: cleaning, inhibitor dosing, filtration and testing.

BS 7671

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The wiring regulations to which the electrical work must be carried out. Part P of the Building Regulations creates the legal duty.

Heat Pumps

The IET Wiring Regulations. Sets the technical requirements for the electrical installation — cable sizing, protective devices, earthing, bonding and testing.

BS EN 12831

Heat Pumps

The standard covering heat loss calculation methods.

BS EN 29453

Water Regs

The standard for soft solder alloys — lead-free tin/copper or tin/silver for capillary joints on copper.

BSRIA

Solar Thermal

The building services research body whose hot water demand formula is 46 + (26 × occupants) litres per day. It disagrees with SAP, so be clear which you are quoting.

Buffer tank

Heat Pumps

A vessel adding system volume, providing a reservoir for the defrost cycle and, in some arrangements, hydraulic separation.

Building control

Unvented

The local authority function that checks and certifies compliance with the Building Regulations.

Building Notice

Unvented

A way of notifying Local Authority Building Control of work before it starts.

Calcium carbonate

Water Regs

Dissolved hardness in raw water. Admitted to a heating system through a failed float valve, it causes rapid scaling.

Capillary joint

Water Regs

A soldered joint in which molten solder is drawn into the gap between pipe and fitting.

Cavitation

Solar Thermal

Vapour bubbles forming and collapsing in a pump. Air in the primary causes it, so the pump churns rather than circulates.

Cavity wall

Water Regs

A wall of two leaves with a cavity between. A pipe may pass through it but must never run within the cavity.

CDM Regulations

Heat Pumps

The Construction (Design and Management) Regulations. They apply to domestic work too, with the client's duties normally passing to the contractor.

Ceiling insulation

Water Regs

Loft insulation laid at ceiling level. Pipes below it are within the thermal envelope; pipes above it are in extreme exposure conditions.

Chase

Water Regs

A groove cut into a wall or floor to receive a pipe. A fitting enclosed in one is a concealed water fitting.

Check valve

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

A valve permitting flow in one direction only. Single check valves give fluid category 2 protection; two in series give category 3.

Unvented

A non-return valve that prevents backflow of hot or expanded water into the cold main.

Circular overflow

Water Regs

A round overflow, as used in type AF and type AG air gap arrangements.

Cistern

Water Regs

A fixed container for holding water at atmospheric pressure.

Clearances

Heat Pumps

The manufacturer's minimum spacing around a unit, for airflow and for service access. They differ on each face, so one figure must not be applied all round.

Closed cell

Water Regs

An insulation structure with sealed cells that will not absorb water — the type required for water pipes.

Closed loop

Heat Pumps

A sealed ground collector circulating a water and antifreeze mixture through buried pipework, exchanging heat with the ground by conduction.

Closed-cell insulation

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Insulation that does not absorb water, so it keeps its value outdoors. Open-cell foam, fibreglass and mineral wool hold water against the pipe and are unsuitable externally.

Heat Pumps

Foam insulation whose sealed cell structure does not absorb water, so it retains its performance outdoors. Needs UV protection and must be continuous.

Coefficient of performance (COP)

Heat Pumps

Heat output divided by electrical input at one stated set of conditions. A working heat pump always exceeds 1; a COP of 3.6 means 3.6 kW of heat per 1 kW of electricity.

Cold fill pressure

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The pressure the system is filled to when cold, taken from the static height of the system plus a margin so the highest point stays positively pressurised.

Heat Pumps

The system pressure when cold. The expansion vessel's gas charge is set to match it, and must be checked with the water side depressurised.

Collector sensor

Solar Thermal

The sensor in the manufacturer's pocket at the collector flow outlet, reading the fluid actually leaving the collector. On the casing, in the return or taped to a pipe it means nothing.

Colour coding

Water Regs

Marking of pipes and cisterns to BS 1710 so non-wholesome pipework is easily distinguished from a supply or distributing pipe.

Combination tap assembly

Water Regs

A single fitting delivering blended hot and cold water, subject to the same tap gap requirements as separate taps.

Combined feed and expansion cistern

Water Regs

A cistern supplying cold water to a hot water system without a separate expansion cistern.

Combined temperature and pressure relief valve

Water Regs

A valve capable of performing the function of both a temperature relief valve and a pressure relief valve.

Commissioning

Unvented

Bringing an unvented system into service through a set sequence, proving every control and recording it.

Commissioning checklist

Solar Thermal

The completed record MIS 3001 requires, produced by following a documented commissioning procedure.

Commissioning record

Heat Pumps

The record of measured values and settings applied at commissioning. The baseline that makes later diagnosis a comparison rather than guesswork.

Competent person scheme

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The route by which most domestic work is self-certified: the registered installer certifies and the scheme notifies the local authority.

Heat Pumps

A scheme allowing a registered installer to self-certify Building Regulations compliance, with the scheme notifying the local authority on their behalf.

Competent Person Scheme (CPS)

Unvented

A scheme whose registered members can self-certify their own notifiable work.

Compressor

Heat Pumps

Raises the pressure of the refrigerant vapour, and its temperature with it. The only component consuming significant electricity, and where the upgrade happens.

Concealed water fitting

Water Regs

A fitting installed below ground, passing through or under a wall, footing or foundation, enclosed in a chase or duct, or otherwise inaccessible or difficult to access.

Condenser

Heat Pumps

The load-side heat exchanger. Hot high-pressure vapour gives up its latent heat to the heating water and condenses back to a liquid.

Conservation area

Heat Pumps

An area designated for its special character. An air source unit keeps its permitted development there, but may not go on a wall or roof that fronts a highway, or nearer a highway than the house.

Contamination

Water Regs

Any reduction in the chemical or biological quality of water due to a change in temperature or the introduction of polluting substances.

Contractor's certificate

Water Regs

The signed certificate an approved contractor must furnish on completion, stating whether the fitting complies with the Regulations.

Control thermostat

Unvented

The everyday thermostat that holds the storage temperature, about 60–65°C.

Controller settings record

Solar Thermal

The written record of the commissioned controller values. It matters because settings drift, customers adjust them, and controls reset after a power failure.

Cooling leg

Solar Thermal

The deliberately uninsulated pipework feeding the expansion vessel, so the diaphragm is not cooked by fluid arriving straight off a stagnating collector. The one place on a solar circuit you insulate less rather than more.

Copper sulphate

Water Regs

A chemical additive named in the fluid category 3 definition.

Correction factor

Heat Pumps

The multiplier converting a catalogue emitter output to its output at the actual design conditions. Divide the room's heat loss by it to find the catalogue size required.

Corrosion inhibitor

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A chemical dosed into system water to protect ferrous components. Depletes over time and is diluted by draining or topping up, so it must be verified at each service.

Water Regs

A chemical dosed into a heating circuit to protect it, and part of why primary water is not wholesome.

COSHH

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The regulations governing hazardous substances. For a heat transfer fluid the assessment is built from the manufacturer's safety data sheet for that specific product.

Heat Pumps

Regulations requiring assessment and control of risks from hazardous substances. Glycol falls under them on heat pump work.

Critical level

Water Regs

The level of fluid in a receptacle under fault conditions, measured at least two seconds after closing the water inlet.

Cylinder coil

Heat Pumps

The heat exchanger inside a cylinder. Heat pump cylinders need a much larger coil — typically about 3 m², following the heat pump and cylinder makers' figures — because the primary temperature is far lower.

D1

Water Regs

The discharge pipe from a safety valve to the tundish. Metal, not less than the nominal outlet size of the valve, and no more than 600 mm long.

D2

Water Regs

The discharge pipe from the tundish to a safe, visible termination. At least one size larger than the valve outlet, with a 300 mm vertical drop below the tundish.

Dead leg

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A length of pipe between the circulating hot water and an outlet. The water in it cools, so a long dead leg means a long wait.

Water Regs

A length of pipe holding water that does not move — a stagnation and bacterial risk, and on hot water a source of undue consumption.

Dead load

Solar Thermal

The permanent weight of collectors, frames and any ballast.

Dedicated circuit

Heat Pumps

A circuit serving the heat pump alone, correctly rated and protected. A plug and socket is unsuitable for a fixed appliance of this load.

Dedicated solar volume

Solar Thermal

The volume of the store served by the solar coil alone: at least 25 litres per net square metre of collector area.

Deemed consent

Water Regs

Consent treated as granted unconditionally where the undertaker gives no notice within ten working days.

Defrost cycle

Heat Pumps

Briefly reverses the refrigerant cycle to melt frost off the outdoor coil. Frost blocks airflow and collapses heat absorption, and is worst in damp weather around 0–6°C.

Demand connection

Heat Pumps

A connection that consumes electricity, as a heat pump does. Distinct from generation connections, which are what G98 and G99 govern.

Depth of cover

Water Regs

The vertical distance from finished ground level to the top of a buried pipe — not less than 750 mm and not more than 1350 mm.

Design external temperature

Heat Pumps

A regional figure representing a cold but realistic winter condition, typically −1°C to −5°C in the UK. Not the coldest ever recorded.

Design flow rate

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

The circulation rate specified for the primary: 0.5 L/min/m² at the low end, 0.6 typical and 0.7 at the high end, per square metre of collector.

Water Regs

The rate of flow that should be available at an outlet when only that outlet, or a group of outlets not exceeding 0.3 l/s, is discharging.

Design flow temperature

Heat Pumps

The water temperature the system is designed to run at. Unit output must be read at this condition, not at the headline test condition, or the installation is quietly undersized.

Design wind pressure

Solar Thermal

The site wind pressure derived under BS EN 1991-1-4 from the building height, the site altitude, the wind zone and the distance from the coast.

Dezincification

Water Regs

Breakdown of a fitting caused by the water reacting with the material itself, leaching zinc from brass and leaving a porous copper structure. Needs only one metal.

Diagnostic reasoning

Heat Pumps

Working from the symptom to the cause rather than replacing components on suspicion. Gather information, verify, read the code, compare with the baseline, then test.

Differential temperature controller

Solar Thermal

The controller comparing the collector sensor against the store sensor, running the pump only when the collector is meaningfully hotter than the part of the store it heats.

Diffuse radiation

Solar Thermal

Sunlight scattered by cloud and atmosphere rather than arriving as a direct beam. It still carries usable energy, which is why UK systems work on overcast days.

Direct flow tube

Solar Thermal

An evacuated tube through which the heat transfer fluid itself passes — a wet connection.

Direct system

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

An open-loop arrangement in which the potable water itself passes through the collector. Rare in the UK because of freezing, scaling and the absence of separation.

Water Regs

A system in which all hot and cold fittings are supplied from the supply pipe at mains pressure, with no cold storage cistern.

Direct-fired cylinder

Unvented

An unvented unit with its own gas or oil burner and factory-fitted controls.

Directly heated

Water Regs

A storage vessel in which the heat source, such as an immersion heater, is in direct contact with the stored water.

Discharge pipe (D1)

Unvented

The metallic pipe from the safety valve to the tundish; at least the valve outlet size and no more than 600mm long.

Discharge pipe (D2)

Unvented

The pipe from the tundish to a safe termination; 300mm straight drop then a 1 in 200 fall, one size larger than the valve outlet.

Disconnector

Water Regs

A device venting an intermediate pressure zone to atmosphere when backflow conditions occur — the CA device is a non-verifiable disconnector.

Disinfection

Water Regs

Treatment of a system after testing and flushing, required for new installations, major extensions, underground pipework, suspected contamination, or a system not in regular use.

Distributing pipe

Water Regs

Any pipe, other than a warning, overflow or flushing pipe, conveying water from a storage cistern or from hot water apparatus supplied from a cistern.

Distribution Network Operator (DNO)

Heat Pumps

The company owning the local electricity cables and network, distinct from the energy supplier. Must be notified of the additional load a heat pump represents.

Diverter valve

Heat Pumps

Switches flow between the heating and hot water circuits, usually with hot water taking priority.

Domestic situation

Water Regs

Wider than 'house' — a hotel counts as domestic for the submerged inlet and shower hose rules. Healthcare premises never do.

Double check valve

Water Regs

Two check valves in series, giving fluid category 3 protection against both backpressure and backsiphonage. Type EC verifiable, type ED non-verifiable.

Double feed indirect

Water Regs

A hot water storage vessel with a separate feed and expansion cistern serving the primary circuit.

Downstream

Water Regs

In the same direction as the flow of water — away from the source.

DRA

Water Regs

Dezincification resistant to approved quality — not less than 200 microns depth in any direction, marked CR or DRA and tested to ISO 6509.

Drain-back system

Solar Thermal

A system in which the fluid falls out of the collectors under gravity into a drain-back vessel whenever the pump stops. Needs no antifreeze and no expansion vessel, and is inherently protected against freezing and stagnation.

Draining tap

Water Regs

A tap provided to drain supply and distributing pipes. Screwdown to BS 2879, or an approved spherical type only in a frost free location.

Drinking fountain

Water Regs

A drinking water facility whose jet nozzle must be at least 25 mm above the spillover level, with a screen or hood.

Dryer receiver

Heat Pumps

Holds a desiccant to absorb moisture and a filter to trap debris. Moisture can freeze at the expansion valve and forms acids that attack the compressor windings.

Dual flush

Water Regs

A flushing device offering two volumes, the lesser not exceeding two-thirds of the greater. A single flush cistern may not be replaced by one.

Duct

Water Regs

An enclosure carrying a pipe. Duct ends at a building entry must be sealed against gas and vermin.

Duty point

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Where the system flow rate, the solar loop pressure drop and the pump characteristics meet — the point at which the chosen pump will actually run.

Heat Pumps

Where the required flow rate and required head meet on a pump curve. Choose the speed curve passing on or above it.

Electricity at Work Regulations

Heat Pumps

Impose the duty to work safely on electrical systems, including isolating and proving dead before work begins.

Electrofusion

Heat Pumps

A jointing method fusing plastic pipe electrically. The only acceptable method for a joint that must be buried.

Emitter

Heat Pumps

Any device giving heat off into a room — radiator, underfloor circuit or fan convector. Output depends on the difference between its surface temperature and the room.

Energy cut-out

Water Regs

A device that shuts off the heat source if the water overheats. Must be non-self-setting where it substitutes for a dedicated cistern.

Equivalent hydraulic resistance

Water Regs

The resistance of a pipe run expressed as an equivalent straight length, counting bends — the basis for sizing a D2 discharge pipe.

ErP label

Heat Pumps

An energy label allowing products to be compared on a consistent basis, showing an efficiency class alongside rated output and sound power level.

Erroneous measurement

Water Regs

Inaccurate metering of water supplied by the undertaker. One of the five Regulation 3 offences.

Escalation

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Referring a fault on rather than improvising — for structural concerns, electrical work beyond your competence, unvented components without G3, or a suspected manufacturing defect under warranty.

Heat Pumps

Referring a fault to the manufacturer or a specialist because it lies beyond your competence or authorisation — refrigerant circuit work being the clearest case.

Ethylene glycol

Water Regs

A substance of low toxicity named in the fluid category 3 definition.

Evacuated tube

Solar Thermal

A collector built from sealed glass tubes under vacuum. The vacuum removes conduction and convection losses, so the advantage shows in cold conditions and at higher working temperatures.

Evaporator

Heat Pumps

The source-side heat exchanger. Low-pressure liquid refrigerant boils here, absorbing heat from the air, ground or water.

Exhaust air heat pump

Heat Pumps

Recovers heat from ventilation air being extracted from the dwelling. Output is capped by the ventilation rate, so it suits small, airtight properties.

Expansion relief valve

Unvented

A safety valve that discharges water to the tundish if pressure rises too far; typically 4 bar (copper) or 6 bar (steel).

Expansion valve

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A controlled restriction that drops the pressure of the liquid refrigerant, lowering its boiling point so it can absorb heat from a cold source. Also regulates superheat.

Water Regs

A pressure-activated valve designed to release expansion water from an unvented water heating system. Fitted close to the vessel with no intervening valves.

Expansion vessel

Heat PumpsSolar ThermalUnventedWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

A vessel accepting the expansion of the fluid as it swings from cold fill to stagnation. Fitted on the return, with its connecting pipework left uninsulated as a cooling leg.

Heat Pumps

Accepts the volume increase of the system contents as they heat. Sized on total system volume, temperature range, fill pressure and relief valve setting.

Water Regs

A vessel connected to a water heating system to accommodate the increase in volume of water when it is heated from cold.

Unvented

A diaphragm vessel with a gas charge that takes up the increased volume of water as it heats; fitted on the cold side.

F-Gas

Heat Pumps

Fluorinated gases used as refrigerants. They have a high global warming potential, are heavier than air, and decompose into toxic products when heated, so their handling is regulated.

F-Gas handling qualification

Heat Pumps

The competence legally required to work on a refrigerant circuit. Needed for split system installation and for any recovery or recharging.

Fabric loss

Heat Pumps

Heat conducted out through walls, roof, floor, windows and doors. Calculated element by element as U × A × ΔT.

Fan convector

Heat Pumps

An emitter using a fan to move air across a coil, giving useful output at low water temperatures from a compact unit.

Fault code

Heat Pumps

A manufacturer-specific code indicating a detected fault. The same number means different things on different makes, so the manufacturer's documentation is essential.

Feed and expansion cistern

Water Regs

The cistern serving a vented primary circuit, sized to accommodate the expansion of the circuit when heated.

Fertilizer

Water Regs

A garden chemical which, applied through a hose, presents a fluid category 3 risk.

Filling and flushing station

Solar Thermal

The equipment used to circulate fluid fast enough during filling to sweep air along with the flow to the vents.

Filling loop

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A temporary connection with backflow protection used to fill a sealed system. Must be physically disconnected after use.

Water Regs

A temporary connecting pipe used to fill a sealed heating system, which must be disconnected after filling. Leaving one connected is an offence.

Fire stopping

Heat Pumps

Proprietary sealing of a service penetration to restore the fire resistance of the wall or floor. Plastic pipe requires an intumescent collar.

Fixed-speed

Heat Pumps

A unit that runs at full output or not at all. Depends heavily on adequate system volume to absorb surplus heat in mild weather.

Flash steam

Unvented

The near-instant conversion of superheated water to steam when pressure is suddenly lost, expanding about 1600 times.

Flashing

Solar Thermal

The weathering detail at a penetration or abutment. Dressed under the tiles above and over the tiles below, so water discharges onto the covering.

FLEQ

Heat Pumps

Full load equivalent run hours — annual energy demand expressed as hours of running at full output. Higher FLEQ means a more demanding duty on the ground and a longer collector.

Float-operated valve

Water Regs

A valve controlling the inflow of water to a cistern, closing as the float rises. Must be adjustable and securely fixed.

Flow rate

Heat Pumps

The volume of water that must circulate to carry the heat, found from kW ÷ (ΔT × 4.18). Inversely proportional to the temperature difference.

Flow verification

Heat Pumps

Confirming the flow rate indirectly by measuring the temperature difference across the heat pump at full output and comparing it with the design figure.

Fluid category

Water Regs

One of the five categories of fluid described in Schedule 1, running from wholesome water to a serious health hazard.

Fluid category 1

Water Regs

Wholesome water supplied by a water undertaker, complying with the drinking water regulations.

Fluid category 2

Water Regs

Water whose aesthetic quality is impaired by a change in temperature, or by substances or organisms changing its taste, odour or appearance. Not a health hazard.

Fluid category 3

Water Regs

Fluid representing a slight health hazard because of the concentration of substances of low toxicity.

Fluid category 4

Water Regs

Fluid representing a significant health hazard because of the concentration of toxic substances, including pesticides and carcinogens.

Fluid category 5

Water Regs

Fluid representing a serious health hazard because of pathogenic organisms, radioactive or very toxic substances — including faecal, human or animal waste.

Flush volume

Water Regs

The quantity of water delivered by a flushing device — not exceeding 6 litres for a single flush.

Flushing

Water Regs

Running water through each length of pipe after installation to remove swarf, jointing compound and excess flux.

Flushing cistern

Water Regs

A cistern provided with a valve or device controlling the discharge of stored water into a WC pan or urinal.

Flux

Water Regs

An acidic paste used when making capillary joints. Excess left in the pipe corrodes copper internally, which is why flushing matters.

Four-pipe buffer connection

Heat Pumps

A buffer with separate flow and return on each side, giving full hydraulic separation at the cost of mixing within the vessel.

Free discharge point

Water Regs

The point at which water discharges to atmosphere — one of the datums used for setting pipe interrupter heights.

Freeze burn

Heat Pumps

A cold burn caused by escaping liquid refrigerant, which evaporates instantly and draws heat from whatever it touches. Skin and eyes are both at risk.

Fully filled pressurised system

Solar Thermal

A sealed primary that remains full at all times, so it must be specified for stagnation and needs antifreeze, an expansion vessel and a pressure relief valve.

Functional controls

Unvented

Controls that protect the water supply and keep the system working properly.

Fusible plug

Water Regs

A non-mechanical safety device that melts at a set temperature. Where fitted, the relief valve must operate at least 5 °C below it.

G3

Solar Thermal

The qualification legally required to work on unvented hot water storage. MCS registration does not cover it.

G98 and G99

Heat Pumps

Engineering Recommendations governing the connection of generation — solar, batteries, anything exporting. They do not apply to heat pumps, which are demand.

Galvanic corrosion

Water Regs

Corrosion driven by an electrical cell formed between two dissimilar metals in contact with water, attacking the less noble metal.

Galvanised steel

Water Regs

Zinc-coated steel pipe. Connecting it downstream of copper drives galvanic corrosion, because zinc is the less noble metal.

Gate valve

Water Regs

A valve closed by a sliding gate, used for cast iron stopvalves of 50 mm and above.

General Permitted Development Order (GPDO)

Heat Pumps

The statutory instrument that grants permitted development rights in England. Amended from time to time, so published guidance often lags behind.

Glass washer

Water Regs

A commercial appliance with a submergible spray hose, presenting a fluid category 4 risk.

Glycol

Heat Pumps

The antifreeze used in ground collector circuits. A hazardous substance under COSHH, and extremely slippery when spilt. Ethylene glycol is far more toxic if ingested than propylene glycol.

Greywater

Water Regs

Water recovered from baths, basins and showers for reuse. Fluid category 5, and restricted to uses that do not need wholesome water.

Ground extraction

Heat Pumps

The heat that must come from the ground: output minus the compressor's electrical input. Sizing an array on full output makes it a third too large.

GS38

Solar Thermal

The HSE guidance on test equipment: probe tips not exceeding 4 mm, with 2 mm strongly recommended, and lead fuses typically not exceeding 500 mA.

Gunmetal

Water Regs

A copper alloy resistant to dezincification, required for concealed fittings and mechanical backflow prevention devices.

Handover

Unvented

Showing the customer the system, explaining not to tamper with the relief valves, and leaving the documentation and service advice.

Handover pack

Heat Pumps

The documentation given to the customer: commissioning record, manufacturer's instructions, compliance certificates, warranty registration and a schematic.

Head

Heat Pumps

The resistance a pump must overcome, measured in metres. Comes from the pipework, fittings, valves and emitters on the hardest circuit.

Headlap

Solar Thermal

The vertical overlap of one course of tiles or slates over the course below. Inadequate headlap lets water track underneath, worse at shallow pitches and on exposed sites.

Heat curve

Heat Pumps

The relationship a compensation control follows between outdoor temperature and flow temperature. Set as low as comfort allows.

Heat extraction rate

Heat Pumps

How much heat a ground collector can draw per metre of pipe, in W/m. Depends on ground conditions and on the annual run hours.

Heat loss calculation

Heat Pumps

Room-by-room calculation of how fast a building loses heat at design conditions. Sizes the unit and every emitter, so errors propagate through the whole design.

Heat loss coefficients

Solar Thermal

The a₁ and a₂ terms in a collector's efficiency curve, describing how quickly efficiency falls as the collector runs hotter than ambient. a₂ dominates at high temperature differences.

Heat pipe tube

Solar Thermal

An evacuated tube containing a sealed working fluid that evaporates, rises to a condenser bulb in the manifold and condenses. A dry connection, so individual tubes can be replaced without draining.

Heat transfer fluid

Solar Thermal

The water and glycol mixture circulating in the primary. It carries less heat per litre than water and is more viscous, which affects flow rate and pump sizing.

HepvO valve

Unvented

A mechanical self-sealing waste valve that allows a discharge into a soil stack when fitted vertically with high-temperature pipe.

High-limit energy cut-out (ECO)

Unvented

A non-self-resetting safety thermostat (about 85–90°C) that cuts the energy source if the control thermostat fails.

High-pressure lockout

Heat Pumps

A protective shutdown when the condensing side cannot reject heat, usually because water flow has fallen. Points to the water side.

Horizontal axis

Water Regs

The drum orientation of a standard domestic washing machine, to which the 27 litre per kilogram limit applies.

Horizontal trench collector

Heat Pumps

Ground collector pipe laid in trenches at around 1.2 m depth. Cheapest to install but land-hungry, typically needing two to three times the heated floor area.

Hose reel

Water Regs

A first-aid firefighting outlet, fluid category 2 where the system contains no additives.

Hose union tap

Water Regs

A tap to which a hose can be connected. Category 3 in a house garden; likely category 5 in non-domestic premises.

Hot water return

Water Regs

The return leg of a secondary circulation system.

House

Water Regs

A single dwelling. The Regulations treat work in a house differently for notification, and assign lower fluid categories to several of its appliances.

Hybrid system

Heat Pumps

A heat pump and boiler under one controller that chooses between them based on outdoor conditions and relative running cost.

Hydrant landing valve

Water Regs

A fire main outlet. Fluid category 2 where the system contains no additives.

Hydraulic impulse device

Water Regs

A urinal control triggered by use of a washbasin tap on the same circuit. Fails if the user does not wash their hands, or uses the hot tap.

Hydrocarbon

Water Regs

Oil, diesel, petrol and similar substances, which permeate through plastics pipe and taint the water without any leak.

Hysteresis

Solar Thermal

The deliberate gap between the switch-on and switch-off differentials, which stops the pump short-cycling on and off around a single threshold.

Immersion heater

Water Regs

An electric heating element fitted directly into a hot water storage vessel.

Impervious lining

Water Regs

The watertight lining or membrane every pond, fountain or pool must have to prevent leakage or seepage of water.

In-roof mounting

Solar Thermal

An area of covering is removed and the collector is weathered into the roof with a proprietary flashing kit, becoming part of the weathering.

Index circuit

Heat Pumps

The circuit with the greatest total resistance. Sizing the pump for it satisfies every easier circuit automatically.

Indicator instrument

Water Regs

An approved alternative to a warning pipe, giving visual or audible warning of impending overflow. Requires the float valve to close 50 mm below overflowing level.

Indirect cylinder

Unvented

An unvented cylinder heated by an external boiler through an internal coil.

Indirect system

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

A closed-loop arrangement in which a sealed primary of water and glycol carries the heat to a coil in the store, never meeting the drinking water. The UK domestic standard.

Water Regs

A system in which outlets are supplied from a storage cistern, usually with the kitchen sink kept on the supply pipe for drinking water.

Infra-red sensor

Water Regs

An electronic presence detector used to flush a urinal only after use, typically requiring around ten seconds of presence.

Inhibitor package

Solar Thermal

The corrosion-inhibiting additives in the heat transfer fluid. Repeated stagnation exhausts them, after which the fluid turns acidic and attacks the system from within.

Injector

Water Regs

The jet arrangement in a type AD air gap, sometimes called a jump jet.

Insecticide

Water Regs

A pesticide. Applied through a hose it raises the risk to fluid category 5, unlike fertilizer at category 3.

Insolation

Solar Thermal

The solar energy accumulated on a surface over a period, measured in kilowatt hours per square metre. A quantity, not a rate.

Instantaneous water heater

Water Regs

A heater raising water temperature on demand rather than storing it. Exempt from the unvented control requirements at 15 litres or less.

Intermediate blending valve

Solar Thermal

A valve limiting the temperature of pre-heated water presented to a downstream appliance that cannot accept it.

Internal air bubble

Unvented

An expansion method using a floating baffle that traps and compresses a pocket of air; needs periodic recharging.

Internal overflow

Water Regs

An overflow discharging into the back of the WC pan instead of an external warning pipe. Accepted conditionally, with a strainer at the float valve.

Interposed cistern

Water Regs

A cistern placed between the supply and an appliance, forming a type AUK1 arrangement — as in a conventional WC suite.

Inverter-driven

Heat Pumps

A unit that varies compressor speed to match demand, so it modulates rather than stopping. Gives long continuous running and the best seasonal efficiency.

Irradiance

Solar Thermal

The rate at which solar radiation arrives on a surface, measured in watts per square metre. A rate, not a quantity.

ISO 6509

Water Regs

The test method for dezincification resistance, to which DRA fittings are tested.

Isolating valve

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

A valve shutting off flow to part of a system. Where a urinal cistern fills automatically, one on a time switch plus a lockable one is required.

Unvented

A valve used to shut the system off from the mains for maintenance.

Jointing compound

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

Used with hemp on solar primary joints. PTFE tape is not dependable at solar temperatures, and soft solder cannot be relied on at stagnation.

Water Regs

A sealing paste for screwed water fittings, complying with BS 6956 Part 5.

Lap roof covering

Solar Thermal

A roof finish in which each element overlaps the one below, so water runs over the joints rather than through them. The lap itself is the weatherproofing.

Latent heat of vaporisation

Heat Pumps

The energy absorbed when a liquid boils into a vapour, released again when it condenses. Far larger than the energy involved in simply warming a fluid, which is why the circuit uses a change of state.

Lawful development certificate

Heat Pumps

Formal written confirmation from the local planning authority that proposed work is permitted development. Worth obtaining on any borderline job.

Lead

Water Regs

A material prohibited in fittings conveying water for domestic or food production purposes, because it leaches into the water.

Legionella

Heat PumpsUnventedWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

Bacteria that can proliferate in stored water within a range of temperatures. Managed by periodic pasteurisation rather than by continuous hot storage.

Water Regs

Bacteria that thrive in water between roughly 20 and 45 °C. The reason hot water is stored at 60 °C, reaches the outlets at 50 °C within a minute (55 °C in healthcare), and cold water is kept below 20 °C.

Unvented

Bacteria that can grow in warm stored water; controlled by storing hot water at 60°C or above.

Line strainer

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

A filter fitted immediately upstream of a backflow prevention device required for fluid category 4, protecting the device seats from debris.

Unvented

A stainless steel gauze filter that removes debris to protect downstream components.

Listed building

Heat Pumps

A building of special historic or architectural interest. Permitted development does not apply; listed building consent is required for external alterations.

Load relieving slab

Water Regs

A slab laid over a pipe trench to spread imposed loads, extending not less than 250 mm either side, used where cover falls below 750 mm.

Loose washer plate

Water Regs

A washer plate not fixed to the valve spindle. Prohibited on stopvalves, servicing valves and draining taps because of unwanted non-return behaviour and noise.

Low loss header

Heat Pumps

A device hydraulically separating two circuits so they can run at different flow rates, while holding only a few litres. Solves flow matching, not volume.

Low-grade heat

Heat Pumps

Heat that is plentiful but at too low a temperature to be directly useful. A heat pump's job is to upgrade it to a temperature that will warm a building.

Low-pressure lockout

Heat Pumps

A protective shutdown when the evaporator cannot absorb enough heat. Points to the source side — a blocked or iced coil, or a collector problem.

Magnetic filter

Heat Pumps

An in-line filter capturing magnetite. Fitted on the return before the heat pump, and cleaned at every service.

Magnetite

Heat Pumps

The black iron oxide sludge formed by corrosion in a heating system. Blocks the narrow waterways of a plate heat exchanger far more readily than a boiler's.

Manifold

Heat Pumps

Where multiple collector circuits come together, with isolation and flow measurement for each. The only point at which a buried array can be diagnosed.

Manual handling hierarchy

Heat Pumps

Avoid, assess, reduce. Ask first whether the handling can be avoided altogether; good lifting technique is a control applied last, not first.

Marker tape

Heat Pumps

Warning tape laid above buried pipework during backfilling, to alert anyone excavating in future.

Material change of use

Water Regs

A change in the purpose for, or the circumstances in which, premises are used — notifiable in its own right.

Maximum allowable roof loading

Solar Thermal

The limit the roof structure can carry. Collectors, frame, ballast and access loads together must fall within it.

Maximum operating pressure

Water Regs

The greatest pressure a system is designed to see in operation, taking account of night-time static pressure and any pumps.

MCS

Solar Thermal

The Microgeneration Certification Scheme. A quality scheme rather than a legal requirement — but the gateway to grant funding.

MCS 004

Solar Thermal

Product certification for solar heating products. The CEN Solar Keymark is the alternative route.

MCS 012

Solar Thermal

Certification for mounting and flashing kits, with declared wind uplift resistance and weathertightness — valid only within the limitations of the certificate.

MCS 020a

Heat Pumps

The MCS planning standard. Sets out how to calculate the sound level from a proposed unit at the assessment position, to demonstrate the noise condition is met.

MCS 024

Solar Thermal

The solar domestic hot water energy calculation.

Method statement

Heat Pumps

Sets out the safe sequence of work putting the risk assessment's control measures into practice.

Microgeneration Certification Scheme (MCS)

Heat Pumps

A voluntary quality scheme. Not a legal requirement, but the gateway to government grant funding and a recognised consumer code.

Mini-irrigation

Water Regs

A garden watering system such as a porous or perforated hose, treated as fluid category 5 where laid at or near the soil surface.

Minimum flow rate

Water Regs

The rate of flow that must still be achieved at an outlet when simultaneous discharge occurs elsewhere in the system.

Minimum system volume

Heat Pumps

The water content a manufacturer requires for a given unit at its permitted starts per hour. Met by pipework, emitters and any added vessel.

MIS 3001

Solar Thermal

The MCS installation standard for solar heating, covering design, sizing, installation, commissioning and handover.

MIS 3005

Heat Pumps

The MCS installation standard for heat pump systems, governing design, sizing, installation, commissioning and handover.

Misuse

Water Regs

Water used for a purpose to which it is not properly put and then discharged. One of the five Regulation 3 offences.

Monobloc

Heat Pumps

An air source unit with the entire refrigerant circuit sealed and factory-charged outdoors. Only water pipes enter the building, so no on-site refrigerant work is needed.

Monovalent system

Heat Pumps

A system with one heat source, sized to meet the full design peak heat loss with no supplementary heat at any outdoor temperature.

Noise assessment position

Heat Pumps

The nearest habitable room window of a neighbouring property, where the sound level from a proposed unit is assessed. The condition protects neighbours, not the installing property.

Non-return valve

Solar Thermal

A check valve preventing the circuit thermosyphoning backwards on a clear night, which would carry heat out of the store, up to the roof, and radiate it to the sky.

Non-self-resetting

Unvented

A safety cut-out that stays tripped until it is reset by hand, so the fault must be found and fixed before resetting.

Non-self-setting

Water Regs

Describes a thermal energy cut-out that will not reset itself, so a fault cannot cycle indefinitely.

Non-storage system

Unvented

An unvented hot water system with a capacity of 15 litres or less.

Notification

Water Regs

Giving notice to the water undertaker before beginning work listed in the Regulation 5 table, and not starting without consent.

Obturator

Water Regs

The moving element that seals against a seat in a valve — a ceramic disc or a washer.

On-roof mounting

Solar Thermal

Brackets pass through the covering to the structure and the collector sits proud of the tiles.

Open loop

Heat Pumps

A ground or water source arrangement that abstracts water, passes it through a heat exchanger and returns or discharges it. Requires an abstraction licence.

Open-vented system

Unvented

A hot water system fed by gravity from a cold cistern, with an open vent pipe to atmosphere.

Operational fitting

Water Regs

A fitting such as a stopvalve, servicing valve or draining tap that must be readily accessible for operation and maintenance.

Over-rim bidet

Water Regs

A bidet with taps above the spillover level and no ascending spray or flexible hose. Needs only a type AUK2 tap gap.

Overall area

Solar Thermal

The complete outside dimensions of a collector including its frame. Used for layout and for wind loading — never for the energy calculation.

Overflow pipe

Water Regs

A pipe from a cistern in which water flows only when the water level exceeds a predetermined level.

Overflowing level

Water Regs

The level at which water would overflow a cistern. Float valves close 25 mm below it, or 50 mm where an alarm replaces the warning pipe.

Overshading

Solar Thermal

Obstruction of the collector by buildings, trees or roof features. An input to the MCS energy calculation, and far more damaging to yield than imperfect orientation.

Oversizing

Heat Pumps

Selecting a unit larger than the design heat loss requires. Causes short cycling rather than providing a safety margin.

Oxygen ingress

Heat Pumps

Oxygen diffusing into system water through non-barrier plastic pipe. Drives continuous corrosion of ferrous components and produces magnetite sludge.

Paragraph 15

Water Regs

The backflow prevention paragraph of Schedule 2 — requiring an adequate device against backflow from any appliance, fitting or process.

Paragraph 16

Water Regs

The cold water services paragraph of Schedule 2 — cistern inlets, outlets, warning pipes, covers and insulation.

Paragraph 25

Water Regs

The WCs, flushing devices and urinals paragraph of Schedule 2.

Parallel grid

Solar Thermal

A collector pipe configuration, sometimes called a harp, where several parallel risers run between a top and bottom header.

Part A (Structure)

Heat Pumps

Building Regulations covering structural stability — relevant when forming openings for pipework or supporting the weight of units and filled cylinders.

Part B (Fire safety)

Heat Pumps

Building Regulations covering fire safety, including fire stopping where services pass through a compartment wall or floor.

Part C (Moisture)

Heat Pumps

Building Regulations covering resistance to contaminants and moisture — weatherproofing and making good penetrations through the external envelope.

Part G (Sanitation and hot water safety)

Heat Pumps

Building Regulations covering hot water storage and safety, including unvented systems and protection against scalding.

Part L (Conservation of fuel and power)

Heat Pumps

Building Regulations covering insulation, system efficiency, controls and commissioning. Remember it as L for Loss of heat.

Part P (Electrical safety)

Heat Pumps

Building Regulations covering electrical safety in dwellings. Creates the legal duty; BS 7671 describes how to satisfy it.

Passing valve

Unvented

A valve that leaks past its seat when it should be shut — for example a pressure-reducing valve passing lets the system pressure creep up.

Passive system

Solar Thermal

A system relying on natural circulation rather than a pump.

Pasteurisation

Solar Thermal

Raising the whole stored volume to at least 60 °C to control legionella. Where solar cannot achieve it, the auxiliary source must.

Pasteurisation cycle

Heat Pumps

A periodic heating of the full cylinder contents to 60°C to manage legionella risk, needed because heat pumps store water at temperatures within the growth range.

Pathogen

Water Regs

A disease-causing organism. Its presence places a fluid in category 5.

Performance estimate

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The property-specific annual energy figure produced by the MCS calculation and given to the customer before they commit. Any later dispute is measured against it.

Heat Pumps

A property-specific statement of expected output, efficiency and running cost, given to the customer before they commit. The benchmark for any later dispute.

Permeation

Water Regs

The passage of contaminants through the wall of a pipe into the water, without any leak. Plastics are permeable to hydrocarbons.

Permitted development

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Planning permission granted nationally by statutory instrument. Solar equipment must project no more than 200 mm from a pitched roof slope, or sit no more than 600 mm above a flat roof.

Heat Pumps

Planning permission granted nationally by statutory instrument, so no application is needed provided every condition is met. The conditions are amended periodically.

Pet cock

Water Regs

A small orifice controlling the slow fill of an automatic urinal cistern. Prone to blocking.

Pipe interrupter

Water Regs

A non-mechanical backflow device with an atmospheric vent that admits air to break a siphon. No control valve may be fitted downstream.

Place setting

Water Regs

The unit by which dishwasher water consumption is measured — not more than 4.5 litres per place setting.

Plug cock

Water Regs

A quarter-turn tapered plug valve, acceptable underground in 15 mm to 50 mm sizes.

Point load

Heat Pumps

A concentrated weight bearing on one part of a structure, such as a filled cylinder on an upper floor. Must be checked against the structure's capacity.

Point of use protection

Water Regs

Backflow protection at the individual appliance, fitting or process. Required by paragraph 15, and never replaced by zone or whole-site protection.

Pond

Water Regs

An ornamental water feature requiring an impervious lining, with no permanent or direct connection to a supply or distributing pipe.

Porous hose

Water Regs

A permeable hose used for irrigation. Category 5 where laid at or near the soil surface.

Pre-charge

Solar ThermalUnvented
TWO MEANINGS — READ BOTH
Solar Thermal

The gas-side pressure set in an expansion vessel. It must be set and checked with the system isolated and the water side depressurised to zero, or the reading means nothing.

Unvented

The air pressure set in an expansion vessel with the system depressurised, sitting just below the expansion-valve setting so the vessel can take up expansion.

Pre-handover check

Heat Pumps

Confirming both that the system genuinely works as intended and that all documentation and certificates are complete and ready to issue.

Pre-installation checklist

Heat Pumps

The structured set of checks completed before work begins, producing a recorded decision on whether the job can proceed as specified.

Premises

Water Regs

The building or land to which water is supplied. Whether premises are a house or not determines many fluid categories.

Pressure flushing cistern

Water Regs

A WC flushing device using supply pipe pressure to compress air and increase the pressure available for flushing.

Pressure flushing valve

Water Regs

A self-closing valve supplied directly from a supply or distributing pipe which discharges a predetermined flush volume when activated. Not permitted in a house.

Pressure reducing valve

Water Regs

A valve holding a constant downstream pressure irrespective of the upstream pressure, used to control excessive static pressure.

Pressure reducing valve (PRV)

Unvented

A valve that sets and stabilises the working pressure regardless of the mains pressure.

Pressure relief valve

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

The last line of defence against overpressure, discharging safely and visibly. A valve quietly passing is how a system loses pressure and freeze protection unnoticed.

Water Regs

A pressure-activated valve which opens automatically at a specified pressure to discharge fluid.

Pressure switch

Heat Pumps

A protective device that shuts the compressor down at abnormal pressure. Which one has tripped — high or low — tells you which side of the machine to investigate.

Pressure-limiting valve

Unvented

A cheaper, less precise alternative to a PRV, used on higher-pressure steel units.

Primary circuit

Water Regs

Water fittings in which water circulates between a boiler or other heat source and a primary heat exchanger inside a hot water storage vessel, including any space heating system.

Prior approval

Solar Thermal

A lighter planning submission than a full application, but still one that must be decided — required for solar equipment on a flat roof on Article 2(3) land.

Projection effect

Solar Thermal

Tilting a surface away from the incoming beam spreads the same energy over a larger area, so the energy received per square metre falls. The reason orientation and tilt matter.

Propylene glycol

Solar Thermal

The antifreeze normally specified for solar primaries, chosen because it is far less toxic if ingested than ethylene glycol.

PTFE tape

Water Regs

Unsintered polytetrafluoroethylene tape for thread sealing, to BS 6974 and satisfying BS 6920 Part 1.

Pump curve

Heat Pumps

A manufacturer's chart showing what a pump delivers at each speed. Each curve slopes downwards, because moving more water leaves less pressure available.

Pump station

Solar Thermal

The assembly carrying the circulator, isolation, check valve, flow indication, pressure gauge, relief valve and vessel connection, usually mounted near the cylinder.

Purging

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Circulating until the fluid runs clear and free of bubbles and flow through the meter is steady rather than surging.

Heat Pumps

Removing trapped air from a filled circuit. A ground collector needs high-velocity circulation from a powered rig, because air vents cannot reach air trapped mid-array.

PVT collector

Solar Thermal

A hybrid panel producing both heat and electricity from the same unit.

Rainwater harvesting

Water Regs

A system collecting rainwater for reuse. Fluid category 5, requiring separation, identification and a category 5 air gap on any mains back-up.

Re-commissioning

Heat Pumps

Setting up and proving the affected parts of a system after a repair, confirming the fault is cleared and nothing was disturbed in the process.

Recirculation

Heat Pumps

An outdoor unit drawing back its own discharged cold air because clearances are inadequate. Lowers the source temperature it sees and collapses output.

Reclaimed water

Water Regs

Water recovered for reuse rather than supplied by the undertaker. Fluid category 5, and colour coded green, black, green.

Reduced pressure zone

Water Regs

The intermediate zone in a BA device, held below the upstream pressure and vented by a relief valve if backflow conditions arise.

Refractometer

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The instrument used to measure glycol concentration and read off the freezing point achieved. The only honest way to verify freeze protection.

Heat Pumps

An instrument measuring antifreeze concentration in a sample. Used to verify freeze protection rather than calculating it from what was added.

Refrigerant

Heat Pumps

The working fluid in a heat pump's sealed circuit, chosen because it boils at a very low temperature. It changes state twice on every lap of the circuit.

Regulation 10

Water Regs

Enforcement — placing the duty to enforce on the water undertaker for its area of appointment.

Regulation 2

Water Regs

Application of the Regulations — what they cover, the temporary supply exemption, and the protection for work lawfully installed before 1 July 1999.

Regulation 3

Water Regs

The restriction on installation and use — the regulation creating the five offences of waste, misuse, undue consumption, contamination and erroneous measurement.

Regulation 4

Water Regs

Requirements for water fittings — appropriate quality and standard, suitability for the circumstances, and installation in a workmanlike manner.

Regulation 5

Water Regs

Notification — the table of work that must be notified to the water undertaker before it begins.

Regulation 6

Water Regs

Contractor's certificate — the requirement for an approved contractor to certify compliance on completion.

Regulation 7

Water Regs

Penalty for contravening the Regulations, and the defence available to an owner or occupier.

Regulator

Water Regs

The Secretary of State, or in Wales the National Assembly — the body that approves specifications and authorises relaxations.

Regulator's Specification

Water Regs

The approved specification for backflow prevention arrangements and devices, setting out the types and their fluid category ratings.

Relaxation

Water Regs

An authorisation from the regulator permitting a Schedule 2 requirement to be relaxed in a particular case. Only the undertaker may apply.

Resin anchor fixing

Heat Pumps

A chemical fixing dispensed under pressure. The resin is an irritant, so eye protection is required, and drilling produces dust and debris.

Reversing valve

Heat Pumps

Swaps the roles of the two heat exchangers, so the outdoor coil temporarily becomes the condenser. This is how the defrost cycle works.

Ring test

Solar Thermal

Tapping an abrasive wheel with something non-metallic and listening for a clear ring, to check for cracks before use.

Risk assessment

Heat Pumps

Identifies hazards, evaluates who might be harmed and how, and records the control measures. Comes before the method statement.

Roof zone

Solar Thermal

The part of the roof an array occupies — centre, edge or corner — which determines the pressure coefficients applied to the design wind pressure.

RPZ

Water Regs

Reduced pressure zone valve assembly — the type BA device. Three pressure zones with a relief valve that opens rather than allowing backflow. Requires annual testing by an accredited tester.

Sacrificial anode

Solar ThermalUnvented
TWO MEANINGS — READ BOTH
Solar Thermal

A magnesium anode in a glass-lined mild steel cylinder that corrodes in place of the steel. Checked and replaced typically every two to three years.

Unvented

A replaceable metal rod that corrodes in place of the cylinder to protect it from corrosion (used in copper cylinders).

Safe isolation

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

Identify, inform, switch off, secure and tag, prove the indicator, test dead, then re-prove the indicator — the last step catching a tester that failed during the test.

Heat Pumps

The seven-step NICEIC procedure: check, isolate, secure, label, prove the indicator, test dead, re-prove. Securing happens at the moment of isolation, before testing dead.

Safety controls

Unvented

Controls that protect the user from overheating and scalding.

Safety data sheet

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The manufacturer's document giving a product's hazards, PPE, first aid, spillage procedure and disposal route. The primary document for any COSHH assessment.

Heat Pumps

The manufacturer's document giving a substance's hazards, required PPE, first aid, spillage procedure and disposal route. The source for a COSHH assessment.

SAP

Solar Thermal

The Standard Assessment Procedure. Its hot water demand formula is (25 × occupants) + 36 litres per day at 52 °C.

Schedule 1

Water Regs

The schedule setting out the five fluid categories.

Schedule 2

Water Regs

Requirements for water fittings — the technical body of the Regulations, carrying their full legal force.

Screened vent

Water Regs

A mesh-protected air inlet allowing a covered cistern to remain at atmospheric pressure while excluding insects.

Screwdown valve

Water Regs

A valve closed by screwing a washered head down onto a seat. Required for underground stopvalves and, normally, draining taps.

Sealed system

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

A heating system pressurised without an open vent or feed and expansion cistern.

Unvented

The primary heating circuit used as a heat source; not the unvented hot water supply.

Seasonal coefficient of performance (SCOP)

Heat Pumps

Efficiency calculated across a whole heating season and a range of outdoor temperatures. A more realistic comparison figure than a single-point COP.

Seasonal performance factor (SPF)

Heat Pumps

Total useful heat delivered divided by total electricity consumed by the whole system over a year, as installed. Counts pumps, controls, defrost and any immersion top-up.

Secondary circuit

Water Regs

Water fittings in which water circulates in the supply or distributing pipes of a hot water storage system.

Secondary circulation

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A return leg with circulator and check valve keeping hot water moving past distant outlets, so it arrives without a long draw-off. Must be insulated. On a heat pump it is a last resort, and the risk assessment then usually calls for more frequent pasteurisation of store and loop.

Water Regs

A hot water return circuit keeping the distribution charged with hot water, removing the dead leg but requiring the return to come back at 50 °C or more (55 °C in healthcare).

Secondary system

Water Regs

The cold feed pipe, hot water storage vessel, water heater and pipework from which hot water is conveyed to all points of draw-off.

Selective coating

Solar Thermal

The absorber surface treatment that takes in a high proportion of incoming solar radiation while re-radiating very little infrared back out.

Self-closing tap

Water Regs

A tap that shuts automatically when released. A basin fitted with them needs no plug, because it cannot be left running.

Separately occupied premises

Water Regs

Premises in distinct occupation, the trigger for whole-site backflow protection and for shared stopvalve access.

Serpentine

Solar Thermal

A collector pipe configuration where a single continuous pipe snakes back and forth across the absorber.

Service box

Water Regs

A raised protective enclosure over an inlet arrangement, used on agricultural troughs where it does not compromise the air gap.

Service record

Heat Pumps

The record of a service visit: date, checks made, readings obtained, parts fitted, defects found and next service due. Readings are what reveal a developing problem.

Servicing access

Heat Pumps

Space to reach a component for maintenance, as distinct from space to install it. The check most often forgotten, and the one that causes trouble for years.

Servicing valve

Water Regs

A valve for shutting off the flow of water to a fitting for the purpose of maintenance or service.

Short cycling

Heat Pumps

Repeated starting and stopping over short periods, caused by the unit producing more heat than the system can absorb. Wears the compressor and depresses seasonal efficiency.

Short-circuiting

Water Regs

Water passing between two cistern connections without circulating through the vessel, leaving stagnant volume behind.

Shower head

Water Regs

A terminal fitting. One that is fixed, or on a hose that cannot be submerged, requires no backflow protection.

Sight glass

Heat Pumps

A window on the liquid line. Clear liquid at steady state is normal; persistent bubbles suggest an undercharge or non-condensable gases.

Single check valve

Water Regs

One check valve permitting flow in one direction only. Fluid category 2 protection in both modes.

Single feed indirect

Water Regs

A hot water storage vessel in which primary and secondary water are separated by an air bubble rather than a second cistern. Requires a permanent vent to atmosphere.

Siphon

Water Regs

The traditional valveless WC flushing mechanism — inherently reliable at not leaking, since there is no seal to fail.

Siphonic

Water Regs

Describes the valveless flushing mechanism relying on a siphon, required for WC cisterns installed before 1 January 2001.

Sleeve

Solar Thermal

The liner around a pipe passing through a wall or roof, letting the pipe move with thermal expansion without abrading or being bonded into the structure.

Sleeving

Heat Pumps

Passing a pipe through a sleeve where it crosses the building fabric, so it can move with thermal expansion without abrading against the masonry.

Slinky coil

Heat Pumps

Overlapped collector pipe laid in a trench, fitting more pipe into a shorter trench. Saves trenching length rather than ground area.

Sodium hypochlorite

Water Regs

Chloros and common disinfectants — named in the fluid category 3 definition.

Solar fraction

Solar Thermal

The share of annual hot water demand supplied by solar. UK designs target 50–60%; pushing beyond it plateaus in benefit and increases stagnation.

Solar Keymark

Solar Thermal

The CEN certification scheme for solar thermal products, an alternative to MCS 004.

Solar PV

Solar Thermal

Photovoltaics — a different technology producing ELECTRICITY rather than heat. Frequently confused with solar thermal.

Solar thermal

Solar Thermal

A system using solar energy to produce HEAT for domestic hot water. A well-designed UK system supplies around 60% of annual hot water, strongly seasonal.

Solenoid valve

Water Regs

An electrically operated valve. Being a control valve, it must never be fitted downstream of a DB or DC pipe interrupter.

Solid floor

Water Regs

A floor of solid construction. No water fitting may be embedded in one.

Sound power level

Heat Pumps

The manufacturer's stated noise output for a unit, used as the input to the MCS 020a planning calculation. Not itself the limit that must be met.

Soundness test

Heat PumpsWater Regs
TWO MEANINGS — READ BOTH
Heat Pumps

A pressure test to confirm pipework is leak-free, carried out before anything is insulated or concealed.

Water Regs

The hydraulic pressure test proving an installation before it is first used, at not less than 1½ times maximum operating pressure.

Source-to-emitter

Heat Pumps

The naming convention for heat pumps. The first word is where heat is collected from, the second is what it is delivered into — so air-to-water collects from air and heats a wet system.

Sparge pipe

Water Regs

The pipe delivering flushing water into a urinal bowl. The datum for the 150 mm pipe interrupter measurement.

Specific heat capacity

Heat Pumps

The energy needed to raise one kilogram of a substance by one degree. For water it is 4.18 kJ/kg·K, the constant in the flow rate formula.

Spherical valve

Water Regs

A quarter-turn ball valve. Acceptable above and below ground, but only with an integral handle or lever when used as a stopvalve.

Spillover level

Water Regs

The level at which the contents of a receiving vessel spill over its top edge when inflow exceeds outflow. The datum for measuring air gaps — the overflow is ignored.

Split system

Heat Pumps

An air source unit with the evaporator outdoors and the condenser and compressor indoors, joined by refrigerant lines charged on site. Requires an F-Gas qualified operative.

Spray tap

Water Regs

A tap delivering a fine spray at low flow. An appliance whose only taps are spray taps needs no plug.

Sprinkler system

Water Regs

A fire protection system. Category 2 without additives; category 4 where anti-freeze is used.

Spur

Solar Thermal

The clearly identified, correctly rated fixed supply to the solar controls, typically 3 A, with local isolation and a label saying what it feeds.

Stagnation

Solar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

The collector receiving solar energy while the pump is not running and no heat is being removed, so it heats until its losses equal the energy arriving.

Water Regs

Water standing without movement, allowing bacterial growth. The reason for bottom outlets, cross-cistern circulation and eliminating dead legs.

Stagnation temperature

Solar Thermal

The temperature a collector reaches under stagnation — roughly 150–200 °C for a flat plate, and above 250 °C for evacuated tubes.

Starting current

Heat Pumps

The surge drawn as a compressor starts, higher than running current. Matters for supply adequacy, particularly on fixed-speed units.

Starts per hour

Heat Pumps

The manufacturer's limit on compressor starts, commonly three to six. Fewer permitted starts means longer runs, which requires more system volume.

Static pressure

Water Regs

The pressure in a system when no water is flowing. It peaks at night when demand on the main is lowest.

Statutory nuisance

Heat Pumps

A noise or other nuisance a local authority can investigate under environmental legislation. Passing the planning noise assessment is not an absolute defence.

Steady state

Heat Pumps

Stable running conditions, reached after warm-up. Commissioning readings taken before this point do not represent normal operation.

Stiction

Water Regs

The initial resistance to movement in a valve at high static pressure, common with ceramic disc taps.

Stopvalve

Water Regs

A valve, other than a servicing valve, used for shutting off the flow of water in a pipe. Its symbol includes a dot in the centre.

Storage cistern

Water Regs

A cistern for storing water for subsequent use, not being a flushing cistern.

Storage system

Unvented

An unvented hot water system with a capacity of more than 15 litres.

Store sensor

Solar Thermal

The sensor low in the cylinder, in the zone the solar coil heats. Fitted high it reads boiler-heated water, the controller sees no useful difference, and the pump never runs.

Stratification

Solar Thermal

The natural layering of hot water above cold in a store. Mixing it presents the solar coil with lukewarm water instead of cold, so transfer and collector efficiency both fall.

Sub-base

Heat Pumps

The compacted layer beneath a concrete base, spreading the load and preventing settlement. A 100 mm slab on poor sub-base will still move.

Submerged inlet

Water Regs

An inlet discharging below the spillover level of an appliance. Category 3 in a house or domestic situation, category 5 elsewhere.

Superheat

Heat Pumps

How far the refrigerant vapour has been heated beyond its boiling point. Maintaining it protects the compressor from liquid carry-over.

Superheated water

Unvented

Water heated above 100°C but kept liquid because it is under pressure.

Supply pipe

Water Regs

So much of a service pipe as is not vested in the water undertaker — the customer's side of the boundary.

Surge

Water Regs

A transient pressure increase, also called water hammer, generated by the rapid closure of a valve. Not accounted for by the test pressure.

Suspended floor

Water Regs

A floor with a void beneath. A pipe entering through one needs insulation at any distance, because the void is ventilated and cold.

Swarf

Water Regs

Metal filings and debris left in pipework by cutting and installation, removed by flushing before the system is used.

Swimming pool

Water Regs

A pool requiring an impervious lining. One over 10,000 litres replenished automatically is notifiable.

Switch-off differential

Solar Thermal

The smaller temperature difference at which the controller stops the pump, typically 2–4 K.

Switch-on differential

Solar Thermal

The temperature difference at which the controller starts the pump, typically 6–8 K.

System efficiency

Heat Pumps

Efficiency measured across the whole installation rather than the unit alone — including auxiliaries, distribution, controls and storage losses.

System schematic

Solar Thermal

The drawing of the installed system handed over to the customer as part of the documentation pack.

Tap gap

Water Regs

The vertical distance between the lowest part of a tap outlet and the spillover level of the appliance it discharges over.

Temperature and pressure relief valve

Unvented

A last-line safety valve that discharges hot water at about 95°C to stop the store overheating.

Temperature difference (ΔT)

Heat Pumps

The gap between flow and return temperatures. Heat pump systems are designed around about 5K, against 20K on boiler systems.

Temperature lift

Heat Pumps

The gap between the source temperature and the flow temperature delivered. The larger the lift, the harder the compressor works and the lower the efficiency.

Temperature relief valve

Water Regs

A valve which opens automatically at a specified temperature to discharge fluid, located directly on the storage vessel.

Terminal fitting

Water Regs

A water outlet device — a tap, shower head or similar.

Test A

Water Regs

The plastics soundness test in which pressure is held by pumping for 30 minutes, deliberately reduced to one third, then must not drop over the following 90 minutes.

Test B

Water Regs

The plastics soundness test in which pressure is noted after 30 minutes of pumping, then must not drop by more than 0.6 bar over 30 minutes and a further 0.2 bar over 120 minutes.

Test port

Water Regs

A tapping on a verifiable device allowing its operation to be checked in situ.

Test pressure

Water Regs

Not less than 1½ times the maximum pressure to which the installation is designed to be subjected in operation.

Thermal envelope

Water Regs

The heated part of a building. Fittings outside it, or outside the building, need protection against freezing.

Thermal store

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

A separate vessel heated by solar that pre-heats the feed to an existing cylinder or appliance.

Heat Pumps

A vessel storing heated primary water. Mains cold water passes through a heat exchanger within it and is heated on demand as it flows.

Thermostatic mixing valve

Heat PumpsSolar ThermalWater Regs
TWO MEANINGS — READ BOTH
Solar Thermal

A valve blending stored hot water with cold at the outlet, so a store hot enough to disinfect is not hot enough to scald.

Heat Pumps

Blends stored hot water down to a safe delivery temperature at the outlet, and shuts off if the cold supply fails. Store hot, deliver safe.

Water Regs

A valve blending hot and cold water to a controlled temperature at the point of use — required at public outlets so discharge does not exceed 43 °C.

Thermostatic mixing valve (TMV)

Unvented

A valve that blends hot and cold to a safe outlet temperature (max 48°C at the bath) to prevent scalding.

Thermostatic radiator valve (TRV)

Heat Pumps

Controls one emitter's output by room temperature. On heat pump systems, TRVs closing reduce circulating volume and can drive cycling.

Thermosyphon

Solar Thermal

Circulation driven by density difference alone. The passive system case, requiring the store above the collector — and the effect a non-return valve exists to prevent running backwards at night.

Tidal volume

Solar Thermal

In a drain-back system, the internal volume of the collectors plus all primary pipework above the drain-back vessel — everything that empties on a stop and refills on a start. It sizes the vessel and sets the pump's lift and priming duty.

Time switch

Water Regs

A clock-operated control regulating when an automatic urinal cistern may fill. Required with a lockable isolating valve.

Total system volume requirement

Heat Pumps

The manufacturer's stated water content for a unit at its permitted starts per hour. Subtract the emitter circuit volume to find the buffer size needed.

Trace heating

Water Regs

Self-regulating heating cable to BS 6351, used with insulation as an accepted method of frost protection.

Trap

Water Regs

A pipe fitting, or part of a sanitary appliance, that retains liquid to prevent the passage of foul air.

Tundish

UnventedWater Regs
TWO MEANINGS — READ BOTH
Water Regs

A funnel in a discharge pipe providing a visible air break between the safety valve (D1) and the discharge to outside (D2).

Unvented

An open funnel that gives a visible 25mm air gap in the discharge, showing when a valve is discharging.

Twin-coil cylinder

Solar ThermalUnvented
TWO MEANINGS — READ BOTH
Solar Thermal

A cylinder with two heating coils — the solar coil low and the auxiliary coil above it, so the collector meets the coldest water in the store.

Unvented

A cylinder with two internal coils so it can take heat from two sources (e.g. solar to the lower coil, boiler to the upper).

Two-pipe buffer connection

Heat Pumps

A buffer connected in series with the circuit. Simple, with no temperature blending, but no hydraulic separation either.

Two-port motorised valve

Heat Pumps

Opens or closes one heating zone in response to that zone's own demand.

Type A upstand

Water Regs

An upward flowing supply or distributing pipe surmounted by an anti-vacuum valve, with any part of the outlet not less than 300 mm above the spillover level of an appliance.

Type AA

Water Regs

Air gap with unrestricted discharge above the spillover level. Fluid category 5 against both backpressure and backsiphonage.

Type AB

Water Regs

Air gap with weir overflow. Fluid category 5 in both modes — the practical category 5 arrangement, since cisterns must have lids.

Type AC

Water Regs

Air gap with vented submerged inlet. Fluid category 3 in both modes.

Type AD

Water Regs

Air gap with injector, sometimes called a jump jet. Fluid category 5 in both modes.

Type AF

Water Regs

Air gap with circular overflow. Fluid category 4 in both modes.

Type AG

Water Regs

Air gap with minimum size circular overflow. Only fluid category 3 — despite beginning with A. Created by a BS 1212 Part 2 float valve in a cistern.

Type AUK1

Water Regs

Air gap with interposed cistern. Category 3 against backpressure but category 5 against backsiphonage — the only arrangement with a split rating.

Type AUK2

Water Regs

The domestic tap gap. 20 mm up to G½, 25 mm above G½ up to G¾, 70 mm above G¾. Category 3 backsiphonage; no backpressure protection.

Type AUK3

Water Regs

The higher risk tap gap — not less than 20 mm or twice the inlet bore, whichever is greater. Category 5 backsiphonage. Sinks anywhere, non-domestic appliances, healthcare.

Type B upstand

Water Regs

A branch pipe serving an appliance where the branch connection to the vented distributing pipe is not less than 300 mm above the spillover level, or the highest discharge point served, whichever is higher.

Type BA

Water Regs

Verifiable backflow preventer with reduced pressure zone — the RPZ valve. Fluid category 4 in both modes, and the only mechanical device that reaches category 4.

Type CA

Water Regs

Non-verifiable disconnector with pressure zones differing by not more than 10%. Category 3 in both modes, and may be left permanently connected.

Type DA

Water Regs

Anti-vacuum valve, or vacuum breaker. Category 3 backsiphonage only, fitted on a 300 mm Type A upstand with no valve on the outlet.

Type DB

Water Regs

Pipe interrupter with atmospheric vent and moving element. Category 4 backsiphonage only. No control valve may be fitted downstream.

Type DC

Water Regs

Pipe interrupter with permanent atmospheric vent. Category 5 backsiphonage only. Vertical pipe, flow downwards, no control valve downstream.

Type DUK1

Water Regs

Anti-vacuum valve combined with a single check valve upstream. Category 2 backpressure, category 3 backsiphonage.

Type EA

Water Regs

Verifiable single check valve. Fluid category 2 in both modes.

Type EB

Water Regs

Non-verifiable single check valve. Fluid category 2 in both modes.

Type EC

Water Regs

Verifiable double check valve. Fluid category 3 in both modes.

Type ED

Water Regs

Non-verifiable double check valve. Fluid category 3 in both modes — the everyday category 3 device.

Type HA

Water Regs

Hose union backflow preventer. Permitted only on existing hose union taps in house installations. Category 2 backpressure, 3 backsiphonage.

Type HC

Water Regs

Diverter with automatic return, integral to some bath/shower combination fittings. Returns the bath outlet to atmosphere if a vacuum occurs. Category 3 backsiphonage.

Type HUK1

Water Regs

Hose union tap incorporating a double check valve. Permitted only for replacing existing hose union taps in house installations.

U-value

Heat Pumps

How readily a building element conducts heat, in W/m²K. A lower figure means better insulation.

Underfloor control pack

Heat Pumps

A blending valve and pump fitted between the primary and the underfloor manifold, blending the flow down to the underfloor design temperature.

Underfloor heating

Heat Pumps

A large-area emitter delivering the load at a mean water temperature around 35°C. The best match for a heat pump because of that low flow temperature.

Undersizing

Heat Pumps

Selecting a unit too small to meet the design heat loss. The system runs continuously in cold weather and relies on backup heat at a COP of 1.

Undue consumption

Water Regs

Using more water than the Regulations permit — one of the five things Regulation 3 exists to prevent.

Unglazed collector

Solar Thermal

A collector with no glazing and no selective coating, used where the required temperature is low — principally swimming pool heating.

Unrestricted discharge

Water Regs

Discharge to atmosphere with nothing impeding the flow or the spillover — the defining feature of a type AA air gap.

Unvented cylinder

Heat Pumps

A cylinder storing domestic hot water at mains pressure. Covered by Building Regulations Part G, with defined discharge arrangements.

Unvented hot water storage vessel

Water Regs

A hot water storage vessel that does not have a vent pipe to the atmosphere.

Unvented system

Unvented

A stored hot water system with no open vent pipe, fed at mains pressure and sealed to atmosphere.

Unwholesome water

Water Regs

Water that does not meet the wholesome standard, and which must be identified and kept separate from supply and distributing pipes.

Upstream

Water Regs

Against the flow of water — back towards the source.

Urinal bowl

Water Regs

An individual urinal appliance. Not subject to the suite approval requirement that applies to WC pans.

Urinal slab

Water Regs

A continuous urinal surface, counted in 700 mm units for the purposes of the automatic cistern filling rate.

Vacuum relief valve

Unvented

A valve that admits air to prevent a vacuum forming and imploding the cylinder.

Vapour barrier

Water Regs

An external layer preventing moisture reaching insulation. Saturated insulation loses most of its effectiveness.

Vapour compression cycle

Heat Pumps

The four-stage process every heat pump uses: compress, condense, expand, evaporate. Compressing the refrigerant raises its temperature enough for the heat to become useful.

Vent pipe

Water Regs

A pipe open to the atmosphere which exposes the system to atmospheric pressure at its boundary. Not less than 19 mm internal diameter.

Vented cylinder

Heat Pumps

A cylinder fed from a cold water storage cistern rather than directly from the mains.

Vented system

Water Regs

A heating or hot water system open to atmosphere through a vent pipe. Deemed the higher risk of vented and sealed.

Ventilation loss

Heat Pumps

The energy needed to warm incoming outside air, calculated from room volume, air change rate and temperature difference.

Verifiable

Water Regs

Describes a backflow prevention device with test ports upstream of and between its mechanical elements, so it can be tested in situ. Verifiability does not change the fluid category rating.

Verification of job information

Heat Pumps

Confirming before commissioning that the design being worked to matches what was actually installed. Commissioning to the wrong figures produces a system that runs but underperforms.

Vertical borehole

Heat Pumps

A drilled ground collector reaching deeper, more thermally stable ground from a small footprint. The answer where land area is the constraint.

Vitreous enamel

Unvented

A glass lining baked onto a steel cylinder during manufacture to prevent corrosion.

Voltage indicator

Heat Pumps

An approved instrument for proving a circuit dead. Must be proved on a known live source both before and after the test. A neon screwdriver is not one.

Volumiser

Heat Pumps

An insulated vessel plumbed in series purely to add water content. Everything flows through it, so there is no mixing penalty and no hydraulic separation.

Warning pipe

Water Regs

An overflow pipe whose outlet is located in a position where the discharge of water can readily be seen. Not less than 19 mm internal diameter.

Washer-drier

Water Regs

A combined washing and drying machine, permitted 48 litres per kilogram because the drying cycle uses additional water.

Washing trough

Water Regs

A communal washing appliance. Exempt from the plug requirement where its outlet cannot accept one and flow does not exceed 0.06 litres per second.

Washload

Water Regs

The unit by which washing machine and washer-drier consumption is measured — litres per kilogram of washload.

Waste

Water Regs

Water escaping and lost — a leaking fitting, a fractured pipe, or a tap left running. One of the five Regulation 3 offences.

Waste duty of care

Heat Pumps

The obligation on whoever removes waste from site to pass it to an authorised person or facility with proper documentation.

Water hammer

Water Regs

The audible symptom of a pressure surge travelling through pipework that is not adequately restrained.

Water hammer arrester

Water Regs

An attenuation device absorbing the pressure spike created by rapid valve closure.

Water softener

Water Regs

An appliance reducing water hardness. Softened water may only be used for drinking where the treated water remains wholesome.

Water Supply (Water Fittings) Regulations

Heat PumpsSolar Thermal
TWO MEANINGS — READ BOTH
Solar Thermal

The regulations keeping inhibited, glycol-bearing water out of the mains. Filling must be through a temporary backflow-protected connection, disconnected afterwards.

Heat Pumps

The regulations protecting the wholesome water supply from contamination by backflow. Byelaws apply in Scotland.

Water supply licensee

Water Regs

A licensed retailer supplying water in the non-household market. The Regulations apply to its supplies as they do to an undertaker's.

Water undertaker

Water Regs

The company appointed to supply water for an area, and the body that enforces these Regulations there.

Waterlogged vessel

Unvented

An expansion vessel whose diaphragm has failed or lost its charge, so it fills with water and can no longer accept expansion.

WaterSafe

Water Regs

The online directory of approved plumbing businesses covering the recognised contractor schemes across the UK.

WC pan

Water Regs

The sanitary appliance receiving the flush. Approved together with its flushing device as a suite.

Weather compensation

Heat Pumps

Varying the flow temperature according to outdoor temperature, following a set curve. The single biggest control lever on seasonal efficiency.

WEEE

Heat Pumps

The arrangements covering disposal of waste electrical and electronic equipment, including old appliances removed during an installation.

Weeping PRV

Solar Thermal

A pressure relief valve passing slightly and continuously. One of the three usual causes of a system losing pressure, alongside a leak and a failed expansion vessel.

Weir overflow

Water Regs

The rectangular slot overflow that distinguishes a type AB air gap, sized to discharge fully under fault conditions.

Whole-site protection

Water Regs

Backflow protection on the supply or distributing pipe serving a whole site, required where a pipe serves two or more separately occupied premises.

Wholesome water

Water Regs

Water supplied by a water undertaker complying with the requirements of the drinking water regulations — fluid category 1.

WIAPS

Water Regs

The Water Industry Approved Plumber Scheme, administered by WRAS and recognised by all water suppliers.

Wind uplift

Solar Thermal

The suction force wind exerts on an array. The critical structural risk for roof-mounted collectors, and highest at roof edges and corners.

Work at height

Solar Thermal

Any place where a person could be injured by falling from it. There is no minimum height, and it includes places at or below ground level.

Working pressure

Unvented

The set outlet pressure the system is designed around, held by the pressure-reducing valve.

Workmanlike manner

Water Regs

The standard required for installation, connection, alteration, repair or disconnection — conforming to an appropriate standard, an approved specification, or a method approved by the undertaker.

WRAS

Water Regs

The Water Regulations Advisory Scheme — publisher of guidance, information and guidance notes, and the approved fittings directory.

Zero-loss efficiency

Solar Thermal

Also optical efficiency, written η₀. A collector's efficiency when there is no temperature difference between it and ambient — the ceiling it works down from.

Zone protection

Water Regs

Backflow protection covering a part of a building, provided in addition to protection at each point of use.

Zoning

Heat Pumps

Dividing a dwelling into separately controlled heating areas. In a new dwelling of 150 m² or more, Approved Document L (5.14) asks for at least two independently controlled heating circuits, each zone with its own time and temperature control.

No matching terms

Try a different word or check the spelling.